Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Chem ; 18(1): 93, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38702794

ABSTRACT

Two rapid, precise, and sensitive stability-indicating high performance chromatographic methods for the measurement of Teriflunomide in its degradation products' existence were developed. These were RP-HPLC and HPTLC using UV detector. HPLC separation was accomplished utilizing Thermo BDS hypercil C18 column (250 × 4.6 mm, 5 µm) and acetonitrile: 0.03 M potassium dihydrogen phosphate: triethylamine (50:50:0.1%, by volume) as mobile phase at flow rate of 1mL/min. The separated peaks were detected at 250.0 nm. The densitometric approach was conducted utilizing HPTLC 60 F254 silica gel plates, and a developing system of benzene: ethanol: acetic acid (7.5:1:0.25, by volume) and detection was done at 250.0 nm. The developed approaches were evaluated regarding the International Conference on Harmonization (ICH) instructions. The calibration curves of both techniques were constructed with linearity ranges of (5-100) µg/mL and (2-10) µg /band, for HPLC and densitometric determination, consecutively. Teriflunomide was exposed to base and acid hydrolysis, oxidation using H2O2 and finally, thermal degradation as stated in ICH guidelines. The degradation product structures' elucidation was achieved through LC-MS.

2.
BMC Chem ; 17(1): 103, 2023 Aug 21.
Article in English | MEDLINE | ID: mdl-37605267

ABSTRACT

Three smart carbon paste electrodes were fabricated to quantify dorzolamide hydrochloride DRZ, including conventional carbon paste I, modified carbon paste embedding Silica II, and modified carbon paste embedding ß-cyclodextrin III. This study is based on the insertion of DRZ with phosphomolybdic acid to create an electroactive moiety dorzolamide-phosphomolybdate ion exchanger using a solvent mediator dibutyl phthalate. The three constructed carbon paste electrodes displayed Nernstian responses and linear concentration ranges with lower detection limits. The vital performance of the created electrodes was verified in relation to various parameters. The electrodes enhance the selective determination of DRZ in the presence of inorganic ions, a co-formulated drug in the dosage form timolol maleate, and the excipient benzalkonium chloride. The modified carbon paste electrode including Silica was utilized to detect DRZ in ophthalmic eye drop form utilizing the direct calibration curve and potentiometric titration methods. Satisfactory findings were achieved by comparing them to other reported methods.

SELECTION OF CITATIONS
SEARCH DETAIL
...