Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Radiol Prot ; 44(2)2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38569480

ABSTRACT

The number of healthcare workers occupationally exposed to ionizing radiation (IR) is increasing every year. As health effects from exposure to low doses IR have been reported, radiation protection (RP) in the context of occupational activities is a major concern. This study aims to assess the compliance of healthcare workers with RP policies, according to their registered cumulative dose, profession, and perception of radiation self-exposure and associated risk. Every healthcare worker from one of the participating hospitals in France with at least one dosimetric record for each year 2009, 2014, and 2019 in the SISERI registry was included and invited to complete an online questionnaire including information on the worker's occupational exposure, perception of IR-exposure risk and RP general knowledge. Hp(10) doses were provided by the SISERI system. Multivariate logistic regressions were used. Dosimeter wearing and RP practices compliance were strongly associated with 'feeling of being IR-exposed' (OR = 3.69, CI95% 2.04-6.66; OR = 4.60, CI95% 2.28-9.30, respectively). However, none of these factors was associated with RP training courses attendance. The main reason given for non-compliance is unsuitability or insufficient numbers of RP devices. This study provided useful information for RP policies. Making exposed workers aware of their own IR-exposure seems to be a key element to address in RP training courses. This type of questionnaire should be introduced into larger epidemiological studies. Dosimeter wearing and RP practices compliance are associated to feeling being IR-exposed. RP training courses should reinforce workers' awareness of their exposure to IR.


Subject(s)
Occupational Exposure , Radiation Protection , Humans , Health Knowledge, Attitudes, Practice , Health Personnel , Radiometry , Radiation, Ionizing , Hospitals , Occupational Exposure/prevention & control , Occupational Exposure/analysis
2.
J Prosthodont ; 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38502779

ABSTRACT

PURPOSE: The aim of this study was to assess Candida albicans attachment on conventionally fabricated (polymethylmethacrylate, PMMA), CAD-CAM milled, and 3D-printed acrylic resin bases pre- and post-simulated thermal aging, along with examining material surface changes after aging. MATERIALS AND METHODS: Forty-six samples (10 mm × 10 mm × 2 mm) for each of four material groups (conventional heat-polymerized PMMA, CAD-CAM milled acrylic resin base, CAD-CAM 3D-printed methacrylate resin base, CAD-CAM 3D-printed urethane methacrylate resin base) were subjected to 0, 1, or 2 years of simulated thermal aging. Microscopic images were taken before and after aging, and C. albicans attachment was quantified using cell proliferation assay (XTT). Statistical analysis employed analysis of variance (α = 0.05). RESULTS: Two-way factorial analysis showed no significant differences based on acrylic resin type or thermal aging (p = 0.344 and p = 0.091 respectively). However, C. albicans attachment significantly differed between 0- and 2-year thermally aged groups (p = 0.004), mainly due to elevated initial attachments on CAD-CAM milled acrylic resin base and CAD-CAM 3D-printed urethane methacrylate resin base. CONCLUSIONS: Regardless of the fabrication technique and material combination, no significant differences were found in C. albicans adhesion pre- or post- thermal aging. Milled and 3D-printed bases compared favorably with heat- polymerized PMMA in their affinity for C. albicans attachment and surface characteristics after aging. These findings indicate that the risk of patients developing denture stomatitis might not be linked to the type of acrylic resin or fabrication method used.

3.
Sci Rep ; 13(1): 6554, 2023 04 21.
Article in English | MEDLINE | ID: mdl-37085548

ABSTRACT

The purpose was to examine patient-centered outcomes and the occurrence of lung fibrotic changes on Chest computed tomography (CT) imaging following pneumonia-related acute respiratory distress syndrome (ARDS). We sought to investigate outpatient clinic chest CT imaging in survivors of COVID19-related ARDS and non-COVID-related ARDS, to determine group differences and explore relationships between lung fibrotic changes and functional outcomes. A retrospective practice analysis of electronic health records at an ICU Recovery Clinic in a tertiary academic medical center was performed in adult patients surviving ARDS due to COVID-19 and non-COVID etiologies. Ninety-four patients with mean age 53 ± 13 and 51% male were included (n = 64 COVID-19 and n = 30 non-COVID groups). There were no differences for age, sex, hospital length of stay, ICU length of stay, mechanical ventilation duration, or sequential organ failure assessment (SOFA) scores between the two groups. Fibrotic changes visualized on CT imaging occurred in a higher proportion of COVID-19 survivors (70%) compared to the non-COVID group (43%, p < 0.001). Across both groups, patients with fibrotic changes (n = 58) were older, had a lower BMI, longer hospital and ICU LOS, lower mean RASS scores, longer total duration of supplemental oxygen. While not statistically different, patients with fibrotic changes did have reduced respiratory function, worse performance on the six-minute walk test, and had high occurrences of anxiety, depression, emotional distress, and mild cognitive impairment regardless of initial presenting diagnosis. Patients surviving pneumonia-ARDS are at high risk of impairments in physical, emotional, and cognitive health related to Post-Intensive Care Syndrome. Of clinical importance, pulmonary fibrotic changes on chest CT occurred in a higher proportion in COVID-ARDS group; however, no functional differences were measured in spirometry or physical assessments at ICU follow-up. Whether COVID infection imparts a unique recovery is not evident from these data but suggest that long-term follow up is necessary for all survivors of ARDS.


Subject(s)
COVID-19 , Pneumonia , Pulmonary Fibrosis , Respiratory Distress Syndrome , Adult , Humans , Male , Middle Aged , Aged , Female , COVID-19/complications , Pulmonary Fibrosis/complications , Pulmonary Fibrosis/diagnostic imaging , Retrospective Studies , Pneumonia/complications , Respiratory Distress Syndrome/etiology , Respiratory Distress Syndrome/epidemiology
4.
Eur Radiol ; 33(8): 5675-5684, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36930262

ABSTRACT

OBJECTIVES: Health workers exposed to ionizing radiation account for + 50% of workers exposed to man-made radiation in France. Over the last decade, the use of radiation in medicine has increased due to the introduction of new practices. The EXposition des Professionnels de santE aux RayonnemenTs ioniSants study aims to evaluate and characterize the trends in radiation exposure of health workers in France between 2009 and 2019. METHODS: This retrospective study includes all health workers with at least one dosimetric record in the system for occupational dosimetry registration (Système d'information de la surveillance de l'exposition aux rayonnements ionisants) database for each of the years 2009, 2014, and 2019, in the hospitals included in the study. Individual external doses and socio-professional data were collected. Statistical analyses include descriptions, graphs, and logistic regressions. RESULTS: A total of 1457 workers were included (mean age: 39.8 years, 59% women). The average exposure significantly decreased between 2009 and 2019 (-0.008 mSv/year, p < 0.05). There were large discrepancies in trends according to professions, departments, hospitals, and gender. Over the 10-year study period, radiologic technologists and physicians were the most exposed (0.15 mSv (95%CI 0.14-0.16) and 0.13 mSv (0.06-0.21), respectively), but their exposure tended to decrease. Workers in nuclear medicine departments had the highest radiation exposure (0.36 mSv (0.33-0.39)), which remained stable over time. Thirty-eight percent of recorded doses were nonzero in 2009, decreasing to 20% in 2019. CONCLUSIONS: This study allowed to identify physicians and radiologic technologists in nuclear medicine departments as the most exposed medical workers in France, and to show an overall decrease trend in radiation exposure. This should be instructive for radiation monitoring and safety of exposed medical workers. KEY POINTS: • Radiation exposure of healthcare workers in most medical departments has steadily decreased between 2009 and 2019 in several French hospitals. • The number of zero doses consistently increased during the study period. • Workers in nuclear medicine departments are the most exposed, especially radiologic technologists and physicians.


Subject(s)
Occupational Exposure , Radiation Exposure , Radiation Monitoring , Humans , Female , Adult , Male , Radiation Dosage , Retrospective Studies , Radiation, Ionizing , Medical Staff
5.
Arch Cardiovasc Dis ; 115(3): 151-159, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35277353

ABSTRACT

BACKGROUND: Catheter ablation (CA) in children using fluoroscopy carries risks inherent to ionizing radiation exposure. AIMS: The objective of this study was to demonstrate the feasibility of using low frames rate during ablation in children to maximally decrease radiation dose. METHODS: Hundred sixty eight successive patients<18 years of age undergoing CA performed under a 3.75 frames/second rate were retrospectively included. Demographics, procedural and dosimetry data were analysed. The effective dose (ED) was evaluated in a subgroup of 14 patients. RESULTS: Median age and weight were 15 years and 54kg, 72% had WPW, 10% AV node reentrant tachycardia, 10% ventricular tachycardia (atrial tachycardia, flutter and atrial fibrillation for the other cases). Acute success was achieved in 98.5% without any complication. Median procedure and fluoroscopy duration were 120 and 16minutes. Median Dose Area Product (DAP) and Air Kerma were 2.46Gy.cm2 and 18 mGy respectively (2Gy.cm2 and 15 mGy for WPW ablation). A significant reduction of median DAP was noted over the years for WPW, from 3.1Gy.cm2 in 2011 to 1.4 in 2019. Median estimated ED was 0.19 mSv (0.03 to 1.64), falling into the range of yearly normal natural irradiation or caused by leasure or professional activity. CONCLUSION: Low frame rate fluoroscopy is a highly effective and safe approach in decreasing radiation exposure during CA in children without altering the success rate of the procedure. ED is low, similar to natural/leisure irradiation. This approach can be considered a good alternative to 3D-based procedures in terms of efficiency and radiation issues, at least for WPW ablations.


Subject(s)
Catheter Ablation , Tachycardia, Supraventricular , Catheter Ablation/adverse effects , Catheter Ablation/methods , Child , Fluoroscopy/adverse effects , Fluoroscopy/methods , Humans , Radiation Dosage , Retrospective Studies , Tachycardia, Supraventricular/etiology , Treatment Outcome
6.
Brain Inj ; 35(7): 842-849, 2021 06 07.
Article in English | MEDLINE | ID: mdl-33678100

ABSTRACT

Background: Patients in intensive care units with traumatic brain injuries (TBI) frequently present acid-base abnormalities and coagulability disorders, which complicate their condition.Objective: To identify protonation through in silico simulations of molecules involved in the process of coagulation in standard laboratory tests.Materials and methods: Ten patients with TBI were selected from the intensive care unit in addition to ten "healthy control subjects", and another nine patients as "disease control subjects"; the latter being a comparative group, corresponding to subjects with diabetes mellitus 2 (DM2). Fibrinogen, FVII, FVIII, FIX, FX, and D-dimer in the presence of acidification were evaluated in 20 healthy subjects in order to compare clinical results with molecular dynamics (MD), and to explain proton interactions and coagulation molecules.Results: The TBI group presented a slight, non-significant increase in D-dimer; but this was not present in "disease control subjects". Levels of fibrinogen, FVII, FIX, FX, and D-dimer were affected in the presence of acidification. We observed that various specific residues of coagulation factors "trap" ions.Conclusion: Protonation of tissue factor and factor VIIa may favor anticoagulant mechanisms, and protonation does not affect ligand binding sites of GPIIb/IIIa (PAC1) suggesting other causes for the low affinity to PAC1.


Subject(s)
Brain Injuries, Traumatic , Protons , Blood Coagulation , Brain Injuries, Traumatic/complications , Humans , Molecular Dynamics Simulation
SELECTION OF CITATIONS
SEARCH DETAIL
...