1.
Article in English | MEDLINE | ID: mdl-32217475

ABSTRACT

Shear-wave elastography (SWE) permits local estimation of tissue elasticity, an important imaging marker in biomedicine. This recently developed, advanced technique assesses the speed of a laterally traveling shear wave after an acoustic radiation force "push" to estimate local Young's moduli in an operator-independent fashion. In this work, we show how synthetic SWE (sSWE) images can be generated based on conventional B-mode imaging through deep learning. Using side-by-side-view B-mode/SWE images collected in 50 patients with prostate cancer, we show that sSWE images with a pixel-wise mean absolute error of 4.5 ± 0.96 kPa with regard to the original SWE can be generated. Visualization of high-level feature levels through t -distributed stochastic neighbor embedding reveals substantial overlap between data from two different scanners. Qualitatively, we examined the use of the sSWE methodology for B-mode images obtained with a scanner without SWE functionality. We also examined the use of this type of network in elasticity imaging in the thyroid. Limitations of the technique reside in the fact that networks have to be retrained for different organs, and that the method requires standardization of the imaging settings and procedure. Future research will be aimed at the development of sSWE as an elasticity-related tissue typing strategy that is solely based on B-mode ultrasound acquisition, and the examination of its clinical utility.


Subject(s)
Deep Learning , Elasticity Imaging Techniques/methods , Image Processing, Computer-Assisted/methods , Humans , Thyroid Gland/diagnostic imaging
3.
Article in English | MEDLINE | ID: mdl-26809594

ABSTRACT

OBJECTIVE: Zygomatic implants may be used for dental rehabilitation in atrophic maxillae. The aim of this study was to establish experimentally the areas of stress distribution using 2 kinds of "All-On-Four" maxillary procedures. STUDY DESIGN: The best position to insert the implants was selected using polyurethane craniomaxillary models and surgical guides were made. Group 1 was designed with two posterior zygomatic implants and two conventional anterior implants, and group 2 with two posterior zygomatic implants and two anterior zygomatic implants. A titanium bar was built to link the 4 implants in both groups. Photoelastic replicas of these models were made and the implants were inserted using the surgical guides. An Instrom 4411 testing machine was used to perform a unilateral compressive loading at the level of the right first molar until 2mm of displacement was obtained. RESULTS: Group 1 showed a high strain concentration in the right lateral orbital region at the level of the apex of the zygomatic implant. Less strain was noticed at the apical levels of the conventional implants in the anterior sector and of the contralateral zygomatic implant. Group 2 showed high strains in the lateral inferior orbital area. The load was low in the alveolar bone sector. DISCUSSION: Zygomatic bone and paranasal structures are loaded at high levels when zygomatic implants are used to stabilize a full maxillary prosthodontic rehabilitation on 4 implants. The use of 4 zygomatic implants loads the alveolar bone to a lower extent and seems better suited from a mechanical point of view than the use of 2 zygomatic implants.


Subject(s)
Dental Implantation, Endosseous/instrumentation , Dental Implantation, Endosseous/methods , Dental Prosthesis, Implant-Supported , Maxilla/surgery , Stress, Mechanical , Zygoma/surgery , Biomechanical Phenomena , Dental Prosthesis Design , Dental Prosthesis, Implant-Supported/adverse effects , Humans , Jaw, Edentulous/surgery , Materials Testing/methods
4.
Genet Mol Res ; 14(4): 16364-71, 2015 Dec 09.
Article in English | MEDLINE | ID: mdl-26662431

ABSTRACT

Babesiosis is an infectious hemolytic disease that occurs worldwide, and is caused by a protozoan of the Babesia genus (Apicomplexa). Little is known about this genus; therefore, this study conducted a molecular characterization of Babesia spp in naturally infected dogs in northern Brazil. Blood samples were collected from 172 dogs from metropolitan Belém, and screened for Babesia spp using semi-nested polymerase chain reactions. Subsequently, 18S rDNA gene fragments were amplified and sequenced. Alignments of the 27 nucleotide sequences returned fragments measuring 1023 bp in size, which did not include any polymorphic sites (100% identity). This genotype was very similar to the 18S rDNA gene in B. vogeli. This study provides an important molecular characterization of the parasite responsible for canine babesiosis in naturally infected dogs in metropolitan Belém. In addition, the 18S rDNA gene in B. vogeli may represent the most common genotype occurring in South America.


Subject(s)
Babesia/genetics , Babesiosis/parasitology , Dog Diseases/parasitology , Animals , Babesia/classification , Brazil , Dogs , Phylogeny , RNA, Protozoan , RNA, Ribosomal, 18S/genetics
5.
Int J Oral Maxillofac Surg ; 43(5): 564-71, 2014 May.
Article in English | MEDLINE | ID: mdl-24239141

ABSTRACT

This study constituted a comparative assessment of the mechanical resistance of square and rectangular 2.0-mm system three-dimensional miniplates as compared to the standard configuration using two straight miniplates. 90 polyurethane replica mandibles were used for the mechanical trials. Groups 1, 2, and 3 simulated complete symphyseal fractures characterized by linear separation of the central incisors; groups 4, 5, and 6 simulated parasymphyseal fractures with an oblique configuration. Groups 1 and 4 represented the standard method with two straight miniplates set parallel to one another. Square miniplates were used in groups 2 and 5, and rectangular miniplates in groups 3 and 6. A universal testing machine set to a velocity of 10mm/min and delivering a vertical linear load to the first left molar was used to test each group. Maximum load values and load values with pre-established dislocation of 5mm were obtained and submitted to statistical analysis using a calculated reliability interval of 95%. The mechanical performances of the devices were similar, except in the case of rectangular plates used in the parasymphyseal fractures. The innovative fixation methods used showed significantly better results in the case of symphyseal fractures.


Subject(s)
Bone Plates , Fracture Fixation, Internal/instrumentation , Mandibular Fractures/surgery , Biomechanical Phenomena , Humans , Models, Anatomic , Polyurethanes , Prosthesis Design , Stress, Mechanical , Titanium
SELECTION OF CITATIONS