1.
Phys Eng Sci Med ; 43(2): 593-599, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32524447

ABSTRACT

Appropriate methods for the determination of very small X-ray beam output factors are essential to ensure correct clinical outcomes for stereotactic radiosurgery. To date, substantial work has been performed in identifying and quantifying suitable dosimeters for relative output factor (ROF) measurements including recent IAEA published recommendations. In this work, we provide a novel method using optically stimulated luminescent dosimeters (OSLDs) with different effective sizes of the readout area to determine ROFs. This involves applying an extrapolation technique to assess ROFs for 6MV SRS X-ray beams with field diameters ranging from 4 to 30 mm as defined by the Brainlab SRS cones. By combining the use of multiple sized OSLDs and water droplets to remove air gaps located around the OSLD detectors, both volume averaging and density variation effects were minimised to estimate ROFs for an extrapolated zero volume detector. The measured results showed that for a 4 mm diameter cone, the ROF was 0.660 ± 0.032 (2SD) as compared to 0.661 ± 0.01 and 0.651 ± 0.018 for the PTW 600019 microDiamond detector and Gafchromic EBT3 film respectively. Whilst the uncertainties were larger than conventional detectors, the technique shows promise and improvements in accuracy may be obtained by higher quality manufacturing techniques. Based on these results, using OSLDs with different effective sizes of readout area and an extrapolation technique shows promise for use as an independent verification tool for very small X-ray field ROFs in the clinical department.


Subject(s)
Algorithms , Luminescence , Radiometry/instrumentation , Radiosurgery/instrumentation , Phantoms, Imaging , X-Rays
2.
Phys Eng Sci Med ; 43(2): 609-616, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32524448

ABSTRACT

To calculate small field output correction factors, [Formula: see text], for Gafchromic EBT3 film using Monte Carlo simulations. These factors were determined for a Novalis Trilogy linear accelerator equipped with Brainlab circular cones with diameters of 4.0 to 30.0 mm. The BEAMnrc Monte Carlo code was used to simulate the Novalis Trilogy linear accelerator and the Brainlab cones with diameters 4.0 to 30 mm. The DOSXYZnrc code was used to simulate Gafchromic EBT3 film with the atomic composition specified by the manufacturer. Small field correction factors were calculated according to new IAEA TRS-483 Code of Practice for small field dosimetry. The depth of calculation was 10 cm and a source to surface distance of 100 cm. The X-ray beam used in the simulations was a 6 MV SRS. The correction factors were then used to determine field output factors with Gafchromic EBT3 film. These field output factors were validated using three solid state detectors and applying correction factors from the TRS-483 Code of Practice. The solid state detectors were IBA SFD diode, PTW 60018 SRS diode and PTW 60019 microDiamond. The Monte Carlo calculated output correction factors, [Formula: see text], for Gafchromic EBT3 film ranged between 0.998 to 1.004 for Brainlab circular cones with diameters between 4.0 and 30.0 mm. The uncertainty for these factors was 2.0%. The field output factors obtained with Gafchromic EBT3 film were within 2% of the mean results obtained with the three solid state detectors. For field sizes 4 mm diameter and above, Gafchromic EBT3 film has field output correction factors within 1% of unity. Therefore, Gafchromic EBT3 film can be considered to be correction less and supports the assumption made about this film in the TRS-483 Code of Practice.


Subject(s)
Algorithms , Monte Carlo Method , Radiometry , Radiosurgery , Computer Simulation
3.
Med Phys ; 43(8): 4687, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27487885

ABSTRACT

PURPOSE: An experimental extrapolation technique is presented, which can be used to determine the relative output factors for very small x-ray fields using the Gafchromic EBT3 film. METHODS: Relative output factors were measured for the Brainlab SRS cones ranging in diameters from 4 to 30 mm(2) on a Novalis Trilogy linear accelerator with 6 MV SRS x-rays. The relative output factor was determined from an experimental reducing circular region of interest (ROI) extrapolation technique developed to remove the effects of volume averaging. This was achieved by scanning the EBT3 film measurements with a high scanning resolution of 1200 dpi. From the high resolution scans, the size of the circular regions of interest was varied to produce a plot of relative output factors versus area of analysis. The plot was then extrapolated to zero to determine the relative output factor corresponding to zero volume. RESULTS: Results have shown that for a 4 mm field size, the extrapolated relative output factor was measured as a value of 0.651 ± 0.018 as compared to 0.639 ± 0.019 and 0.633 ± 0.021 for 0.5 and 1.0 mm diameter of analysis values, respectively. This showed a change in the relative output factors of 1.8% and 2.8% at these comparative regions of interest sizes. In comparison, the 25 mm cone had negligible differences in the measured output factor between zero extrapolation, 0.5 and 1.0 mm diameter ROIs, respectively. CONCLUSIONS: This work shows that for very small fields such as 4.0 mm cone sizes, a measureable difference can be seen in the relative output factor based on the circular ROI and the size of the area of analysis using radiochromic film dosimetry. The authors recommend to scan the Gafchromic EBT3 film at a resolution of 1200 dpi for cone sizes less than 7.5 mm and to utilize an extrapolation technique for the output factor measurements of very small field dosimetry.


Subject(s)
Film Dosimetry/methods , X-Rays
4.
Med Phys ; 41(11): 111702, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25370616

ABSTRACT

PURPOSE: Small field x-ray beam dosimetry is difficult due to lack of lateral electronic equilibrium, source occlusion, high dose gradients, and detector volume averaging. Currently, there is no single definitive detector recommended for small field dosimetry. The objective of this work was to evaluate the performance of a new commercial synthetic diamond detector, namely, the PTW 60019 microDiamond, for the dosimetry of small x-ray fields as used in stereotactic radiosurgery (SRS). METHODS: Small field sizes were defined by BrainLAB circular cones (4-30 mm diameter) on a Novalis Trilogy linear accelerator and using the 6 MV SRS x-ray beam mode for all measurements. Percentage depth doses (PDDs) were measured and compared to an IBA SFD and a PTW 60012 E diode. Cross profiles were measured and compared to an IBA SFD diode. Field factors, ΩQclin,Qmsr (fclin,fmsr) , were calculated by Monte Carlo methods using BEAMnrc and correction factors, kQclin,Qmsr (fclin,fmsr) , were derived for the PTW 60019 microDiamond detector. RESULTS: For the small fields of 4-30 mm diameter, there were dose differences in the PDDs of up to 1.5% when compared to an IBA SFD and PTW 60012 E diode detector. For the cross profile measurements the penumbra values varied, depending upon the orientation of the detector. The field factors, ΩQclin,Qmsr (fclin,fmsr) , were calculated for these field diameters at a depth of 1.4 cm in water and they were within 2.7% of published values for a similar linear accelerator. The corrections factors, kQclin,Qmsr (fclin,fmsr) , were derived for the PTW 60019 microDiamond detector. CONCLUSIONS: The authors conclude that the new PTW 60019 microDiamond detector is generally suitable for relative dosimetry in small 6 MV SRS beams for a Novalis Trilogy linear equipped with circular cones.


Subject(s)
Radiometry/methods , Radiosurgery/methods , Algorithms , Diamond/chemistry , Humans , Monte Carlo Method , Particle Accelerators , Radiotherapy Planning, Computer-Assisted , Water/chemistry , X-Rays