1.
Entropy (Basel) ; 23(2)2021 Feb 23.
Article in English | MEDLINE | ID: mdl-33672152

ABSTRACT

In this paper, we explore the advantages of a fractional calculus based watermarking system for detecting Gaussian watermarks. To reach this goal, we selected a typical watermarking scheme and replaced the detection equation set by another set of equations derived from fractional calculus principles; then, we carried out a statistical assessment of the performance of both schemes by analyzing the Receiver Operating Characteristic (ROC) curve and the False Positive Percentage (FPP) when they are used to detect Gaussian watermarks. The results show that the ROC of a fractional equation based scheme has 48.3% more Area Under the Curve (AUC) and a False Positives Percentage median of 0.2% whilst the selected typical watermarking scheme has 3%. In addition, the experimental results suggest that the target applications of fractional schemes for detecting Gaussian watermarks are as a semi-fragile image watermarking systems robust to Gaussian noise.

2.
Biomed Res Int ; 2019: 2608547, 2019.
Article in English | MEDLINE | ID: mdl-30915349

ABSTRACT

Methods of the electrocardiography (ECG) signal features extraction are required to detect heart abnormalities and different kinds of diseases. However, different artefacts and measurement noise often hinder providing accurate features extraction. One of the standard techniques developed for ECG signals employs linear prediction. Referring to the fact that prediction is not required for ECG signal processing, smoothing can be more efficient. In this paper, we employ the p-shift unbiased finite impulse response (UFIR) filter, which becomes smooth by p < 0. We develop this filter to have an adaptive averaging horizon: optimal for slow ECG behaviours and minimal for fast excursions. It is shown that the adaptive UFIR algorithm developed in such a way provides better denoising and suboptimal features extraction in terms of the output signal-noise ratio (SNR). The algorithm is developed to detect durations and amplitudes of the P-wave, QRS-complex, and T-wave in the standard ECG signal map. Better performance of the algorithm designed is demonstrated in a comparison with the standard linear predictor, UFIR filter, and UFIR predictive filter based on real ECG data associated with normal heartbeats.


Subject(s)
Algorithms , Arrhythmias, Cardiac/physiopathology , Electrocardiography/methods , Signal Processing, Computer-Assisted , Female , Humans , Male , Signal-To-Noise Ratio
SELECTION OF CITATIONS
SEARCH DETAIL
...