Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Cardiovasc Eng Technol ; 14(1): 152-165, 2023 02.
Article in English | MEDLINE | ID: mdl-36151366

ABSTRACT

PURPOSE: Areas of disturbed shear that arise following arteriovenous fistula (AVF) creation are believed to contribute to the development of intimal hyperplasia (IH). The presence of helical flow can suppress areas of disturbed shear, which may protect the vasculature from IH. Therefore, the aim of this study is to determine if helical flow, specifically spiral laminar flow (SLF), is present in patient-specific AVF models and is associated with a reduction in exposure to disturbed shear. METHODS: Four AVF were imaged using MRI within the first two weeks following fistula creation. Patient-specific boundary conditions were obtained using phase-contrast MRI and applied at the inlet and outlets of each model. Computational fluid dynamics was used to analyse the hemodynamics in each model and compare the helical content of the flow to the distribution of disturbed shear. RESULTS: BC-1 and RC-2 are characterised by the presence of SLF, which coincides with the lowest distribution of disturbed shear. Contrastingly, SLF is absent from BC-2 and RC-1 and experience the largest amount of disturbed shear. Interestingly, BC-2 and RC-1 developed an anastomosis stenosis, while BC-1 and RC-2 remained stenosis free. CONCLUSION: These findings are in agreement with previous clinical studies and further highlight the clinical potential of SLF as a prognostic marker for a healthy AVF, as its presence correlates with an overall reduction in exposure to disturbed shear and a decrease in the incidence of AVF dysfunction, albeit in a small sample size.


Subject(s)
Arteriovenous Fistula , Arteriovenous Shunt, Surgical , Humans , Hemodynamics , Arteriovenous Fistula/diagnostic imaging , Anastomosis, Surgical , Magnetic Resonance Imaging , Arteriovenous Shunt, Surgical/adverse effects , Renal Dialysis
2.
Int J Numer Method Biomed Eng ; 35(12): e3259, 2019 12.
Article in English | MEDLINE | ID: mdl-31483945

ABSTRACT

Areas of disturbed shear that develop following arteriovenous fistula (AVF) creation are believed to trigger the onset of intimal hyperplasia (IH), leading to AVF dysfunction. The presence of helical flow can suppress the flow disturbances that lead to disturbed shear in other areas of the vasculature. However, the relationship between helical flow and disturbed shear remains unevaluated in AVF. In this study, computational fluid dynamics (CFD) is used to evaluate the relationship between geometry, helical flow, and disturbed shear in parameterised models of an AVF characterised by four different anastomosis angles. The AVF models with a small anastomosis angle demonstrate the lowest distribution of low/oscillating shear and are characterised by a high helical intensity coupled with a strong balance between helical structures. Contrastingly, the models with a large anastomosis angle experience the least amount of high shear, multidirectional shear, as well as spatial and temporal gradients of shear. Furthermore, the intensity of helical flow correlates strongly with curvature (r = 0.73, P < .001), whereas it is strongly and inversely associated with taper (r = -0.87, P < .001). In summary, a flow field dominated by a high helical intensity coupled with a strong balance between helical structures can suppress exposure to low/oscillating shear but is ineffective when it comes to other types of shear. This highlights the clinical potential of helical flow as a diagnostic marker of exposure to low/oscillating shear, as helical flow can be identified in vivo with the use of ultrasound imaging.


Subject(s)
Arteriovenous Fistula/physiopathology , Models, Cardiovascular , Blood Flow Velocity , Humans , Hydrodynamics , Pulsatile Flow , Shear Strength
SELECTION OF CITATIONS
SEARCH DETAIL
...