Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 85(11): 115104, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430146

ABSTRACT

Resonant Inelastic X-ray Scattering (RIXS) in the soft x-ray range is an element-specific energy-loss spectroscopy used to probe the electronic and magnetic excitations in strongly correlated solids. In the recent years, RIXS has been progressing very quickly in terms of energy resolution and understanding of the experimental results, but the interpretation of spectra could further improve, sometimes decisively, from a full knowledge of the polarization of incident and scattered photons. Here we present the first implementation, in a high resolution soft-RIXS spectrometer used to analyze the scattered radiation, of a device allowing the measurement of the degree of linear polarization. The system, based on a graded W/B4C multilayer mirror installed in proximity of the CCD detector, has been installed on the AXES spectrometer at the ESRF (European Synchrotron Radiation Facility); it has been fully characterized and it has been used for a demonstration experiment at the Cu L3 edge on a high-Tc superconducting cuprate. The loss in efficiency suffered by the spectrometer equipped with this test facility was a factor 17.5. We propose also a more advanced version, suitable for a routine use on the next generation of RIXS spectrometers and with an overall efficiency up to 10%.

2.
J Synchrotron Radiat ; 12(Pt 5): 659-64, 2005 Sep.
Article in English | MEDLINE | ID: mdl-16120991

ABSTRACT

A new state-of-the art synchrotron beamline fully optimized for monochromatic X-ray diffraction at high pressure and high (or low) temperature is presented. In comparison with the old high-pressure beamline ID30, this new beamline exhibits outstanding performance in terms of photon flux and focusing capabilities. The main components of this new instrument will be described in detail and compared with the performance of beamline ID30. In particular, the choices in terms of X-ray source, X-ray optics, sample environment and detectors are discussed. The first results of the beamline commissioning are presented.

3.
J Synchrotron Radiat ; 5(Pt 6): 1357-62, 1998 Nov 01.
Article in English | MEDLINE | ID: mdl-16687848

ABSTRACT

The diffraction of an X-ray beam on an ultrasonic wave propagating at the surface of a crystal gives rise to diffraction satellites whose temporal structure is correlated to that of the ultrasonic wave. By matching the temporal structure of the surface acoustic wave with the filling mode of the storage ring, it is possible to select or reject the incident X-ray pulses. A few examples of the performance of this MHz-range chopper for various filling modes are presented.

SELECTION OF CITATIONS
SEARCH DETAIL
...