Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Eur Radiol ; 34(2): 1388-1398, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37589906

ABSTRACT

OBJECTIVES: Digital breast tomosynthesis (DBT) can improve diagnostic accuracy compared to 2D mammography, but DBT reporting is time-consuming and potentially more fatiguing. Changes in diagnostic accuracy and subjective and objective fatigue were evaluated over a DBT reporting session, and the impact of taking a reporting break was assessed. MATERIALS AND METHODS: Forty-five National Health Service (NHS) mammography readers from 6 hospitals read a cancer-enriched set of 40 DBT cases whilst eye tracked in this prospective cohort study, from December 2020 to April 2022. Eye-blink metrics were assessed as objective fatigue measures. Twenty-one readers had a reporting break, 24 did not. Subjective fatigue questionnaires were completed before and after the session. Diagnostic accuracy and subjective and objective fatigue measures were compared between the cohorts using parametric and non-parametric significance testing. RESULTS: Readers had on average 10 years post-training breast screening experience and took just under 2 h (105.8 min) to report all cases. Readers without a break reported greater levels of subjective fatigue (44% vs. 33%, p = 0.04), which related to greater objective fatigue: an increased average blink duration (296 ms vs. 286 ms, p < 0.001) and a reduced eye-opening velocity (76 mm/s vs. 82 mm/s, p < 0.001). Objective fatigue increased as the trial progressed for the no break cohort only (ps < 0.001). No difference was identified in diagnostic accuracy between the groups (accuracy: 87% vs. 87%, p = 0.92). CONCLUSIONS: Implementing a break during a 2-h DBT reporting session resulted in lower levels of subjective and objective fatigue. Breaks did not impact diagnostic accuracy, which may be related to the extensive experience of the readers. CLINICAL RELEVANCE STATEMENT: DBT is being incorporated into many mammography screening programmes. Recognising that reporting breaks are required when reading large volumes of DBT studies ensures this can be factored in when setting up reading sessions. TRIAL REGISTRATION: Clinical trials registration number: NCT03733106 KEY POINTS: • Use of digital breast tomosynthesis (DBT) in breast screening programmes can cause significant reader fatigue. • The effectiveness of incorporating reading breaks into DBT reporting sessions, to reduce mammography reader fatigue, was investigated using eye tracking. • Integrating breaks into DBT reporting sessions reduced reader fatigue; however, diagnostic accuracy was unaffected.


Subject(s)
Breast Neoplasms , Reading , Humans , Female , Prospective Studies , State Medicine , Mammography/methods , Breast/diagnostic imaging , Early Detection of Cancer/methods , Breast Neoplasms/diagnostic imaging
2.
Radiology ; 283(2): 371-380, 2017 05.
Article in English | MEDLINE | ID: mdl-28287917

ABSTRACT

Purpose To assess whether individual reader performance with digital breast tomosynthesis (DBT) and two-dimensional (2D) mammography varies with number of years of experience or volume of 2D mammograms read. Materials and Methods After written informed consent was obtained, 8869 women (age range, 29-85 years; mean age, 56 years) were recruited into the TOMMY trial (A Comparison of Tomosynthesis with Digital Mammography in the UK National Health Service Breast Screening Program), an ethically approved, multicenter, multireader, retrospective reading study, between July 2011 and March 2013. Each case was read prospectively for clinical assessment and to establish ground truth. A retrospective reading data set of 7060 cases was created and randomly allocated for independent blinded review of (a) 2D mammograms, (b) DBT images and 2D mammograms, and (c) synthetic 2D mammograms and DBT images, without access to previous examinations. Readers (19 radiologists, three advanced practitioner radiographers, and two breast clinicians) who had 3-25 (median, 10) years of experience in the U.K. National Health Service Breast Screening Program and read 5000-13 000 (median, 8000) cases per annum were included in this study. Specificity was analyzed according to reader type and years and volume of experience, and then both specificity and sensitivity were analyzed by matched inference. The median duration of experience (10 years) was used as the cutoff point for comparison of reader performance. Results Specificity improved with the addition of DBT for all readers. This was significant for all staff groups (56% vs 68% and 49% vs 67% [P < .0001] for radiologists and advanced practitioner radiographers, respectively; 46% vs 55% [P = .02] for breast clinicians). Sensitivity was improved for 19 of 24 (79%) readers and was significantly higher for those with less than 10 years of experience (91% vs 86%; P = .03) and those with total mammographic experience of fewer than 80 000 cases (88% vs 86%; P = .03). Conclusion The addition of DBT to conventional 2D screening mammography improved specificity for all readers, but the gain in sensitivity was greater for readers with less than 10 years of experience.


Subject(s)
Breast Neoplasms/diagnostic imaging , Clinical Competence/statistics & numerical data , Mammography/statistics & numerical data , Observer Variation , Radiologists/statistics & numerical data , Tomography, X-Ray Computed/statistics & numerical data , Adult , Aged , Aged, 80 and over , Breast Neoplasms/epidemiology , Female , Humans , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , United Kingdom/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...