Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Microbiol ; 41(4): 1586-93, 2003 04.
Article in English | MEDLINE | ID: mdl-12682149

ABSTRACT

Drug resistance and poor virological responses are associated with well-characterized mutations in the viral reading frames that encode the proteins that are targeted by currently available antiretroviral drugs. An integrated system was developed that includes target gene amplification, DNA sequencing chemistry (TRUGENE HIV-1 Genotyping Kit), and hardware and interpretative software (the OpenGene DNA Sequencing System) for detection of mutations in the human immunodeficiency virus type 1 (HIV-1) protease and reverse transcriptase sequences. The integrated system incorporates reverse transcription-PCR from extracted HIV-1 RNA, a coupled amplification and sequencing step (CLIP), polyacrylamide gel electrophoresis, semiautomated analysis of data, and generation of an interpretative report. To assess the accuracy and robustness of the assay system, 270 coded plasma specimens derived from nine patients were sent to six laboratories for blinded analysis. All specimens contained HIV-1 subtype B viruses. Results of 270 independent assays were compared to "gold standard" consensus sequences of the virus populations determined by sequence analysis of 16 to 20 clones of viral DNA amplicons derived from two independent PCRs using primers not used in the kit. The accuracy of the integrated system for nucleotide base identification was 98.7%, and the accuracy for codon identification at 54 sites associated with drug resistance was 97.6%. In a separate analysis of plasma spiked with infectious molecular clones, the assay reproducibly detected all 72 different drug resistance mutations that were evaluated. There were no significant differences in accuracy between laboratories, between technologists, between kit lots, or between days. This integrated assay system for the detection of HIV-1 drug resistance mutations has a high degree of accuracy and reproducibility in several laboratories.


Subject(s)
Anti-HIV Agents/pharmacology , Drug Resistance, Viral/genetics , HIV Infections/virology , HIV-1/classification , HIV-1/genetics , Reagent Kits, Diagnostic , Gene Amplification , Genotype , HIV Protease/genetics , HIV Reverse Transcriptase/genetics , HIV-1/drug effects , Humans , Laboratories , Molecular Sequence Data , Mutation , RNA, Viral/blood , Reproducibility of Results , Sequence Analysis, DNA , Software
2.
J Clin Microbiol ; 41(4): 1594-9, 2003 04.
Article in English | MEDLINE | ID: mdl-12682150

ABSTRACT

The TRUGENE HIV-1 Genotyping Kit and OpenGene DNA Sequencing System are designed to sequence the protease (PR)- and reverse transcriptase (RT)-coding regions of human immunodeficiency virus type 1 (HIV-1) pol. Studies were undertaken to determine the accuracy of this assay system in detecting resistance-associated mutations and to determine the effects of RNA extraction methods, anticoagulants, specimen handling, and potentially interfering substances. Samples were plasma obtained from HIV-infected subjects or seronegative plasma to which viruses derived from wild-type and mutant infectious molecular clones (IMC) of HIV-1 were added. Extraction methods tested included standard and UltraSensitive AMPLICOR HIV-1 MONITOR, QIAGEN viral RNA extraction mini kit, and QIAGEN Ultra HIV extraction kit, and NASBA manual HIV-1 quantitative NucliSens. Sequence data from test sites were compared to a "gold standard" reference sequence to determine the percent agreement. Comparisons between test and reference sequences at the nucleotide level showed 97.5 to 100% agreement. Similar results were obtained regardless of extraction method, regardless of use of EDTA or acid citrate dextrose as anticoagulant, and despite the presence of triglycerides, bilirubin, hemoglobin, antiretroviral drugs, HIV-2, hepatitis C virus (HCV), HBV, cytomegalovirus, human T-cell leukemia virus type 1 (HTLV-1), or HTLV-2. Samples with HIV-1 RNA titers of >or=1,000 copies/ml gave consistent results. The TRUGENE HIV-1 Genotyping Kit and OpenGene DNA Sequencing System consistently generate highly accurate sequence data when tested with IMC-derived HIV and patient samples.


Subject(s)
Drug Resistance, Viral/genetics , HIV-1/drug effects , RNA, Viral/blood , Reagent Kits, Diagnostic , Sequence Analysis, DNA , Anticoagulants , Genotype , HIV Infections/virology , HIV Protease/genetics , HIV Reverse Transcriptase/genetics , HIV-1/enzymology , HIV-1/genetics , Humans , Molecular Sequence Data , Mutation , RNA, Viral/isolation & purification , Specimen Handling/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...