Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Shoulder Elbow Surg ; 32(8): 1740-1745, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37044303

ABSTRACT

BACKGROUND: The aim of this study was to examine the incidence of overweight and obesity in patients undergoing primary total shoulder arthroplasty (TSA) for osteoarthritis (OA) in Australia compared to the incidence of obesity in the general population. MATERIALS AND METHODS: A 2017/18 cohort consisting of 2997 patients from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) who underwent TSA were compared with matched controls from the Australian Bureau of Statistics (ABS) National Health Survey from the same time period. The 2 groups were analyzed according to body mass index (BMI) category, sex, and age. RESULTS: According to the 2017/18 National Health Survey, 35.6% of Australian adults were overweight and 31.3% were obese. Of the primary TSA cases performed, 34.9% were overweight and 50.1% were obese. The relative risk of requiring TSA for OA increased with increasing BMI category. Class III obese females, aged 55-64, were 8.6 times more likely to receive a TSA compared to their normal weight counterparts. Males in the same age and BMI category were 2.5 times more likely. Class III obese patients underwent TSA 4 years (female) and 6 years (male) younger than their normal weight counterparts. CONCLUSION: Obesity significantly increases the risk of requiring TSA. The association appears to be particularly strong for younger females.


Subject(s)
Arthroplasty, Replacement, Shoulder , Osteoarthritis , Shoulder Joint , Adult , Humans , Male , Female , Arthroplasty, Replacement, Shoulder/adverse effects , Overweight , Australia/epidemiology , Obesity/complications , Obesity/epidemiology , Osteoarthritis/epidemiology , Osteoarthritis/surgery , Osteoarthritis/complications , Shoulder Joint/surgery
2.
J Hand Surg Eur Vol ; 46(6): 616-620, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33861659

ABSTRACT

We conducted a systematic review of scaphoid plating for recalcitrant scaphoid fractures using EMBASE, Pubmed, Cochrane and MEDLINE. Thirteen studies were included. Ninety-three per cent of cases reported were male with a mean age of 27 years. Bony union was reported in eleven studies and achieved in 72% to 100% of cases. Scaphoid plates showed no significant difference in union incidence compared with headless compression screws. Mean removal incidence of plates was 21%. Postoperative flexion-extension arc was 119°. Grip strength improved by 14% postoperatively over that before surgery. There was a general improvement in patient-reported outcome measures. Eighty-six per cent of reported participants returned to their previous work. In these clinical reports, plates frequently required removal more frequently than headless compression screws.


Subject(s)
Fractures, Bone , Fractures, Ununited , Scaphoid Bone , Adult , Bone Screws , Fracture Fixation, Internal , Fractures, Bone/surgery , Humans , Male , Retrospective Studies , Scaphoid Bone/surgery , Treatment Outcome
3.
EFORT Open Rev ; 5(5): 312-318, 2020 May.
Article in English | MEDLINE | ID: mdl-32509336

ABSTRACT

Unicompartmental knee arthroplasty (UKA) is associated with improved functional outcomes but reduced implant survivorship compared to total knee arthroplasty (TKA).Surgeon-controlled errors in component positioning are the most common reason for implant failure in UKA, and low UKA case-volume is associated with poor implant survivorship and earlier time to revision surgery.Robotic UKA is associated with improved accuracy of achieving the planned femoral and tibial component positioning compared to conventional manual UKA.Robotic UKA has a learning curve of six operative cases for achieving operative times and surgical team comfort levels comparable to conventional manual UKA, but there is no learning curve effect for accuracy of implant positioning or limb alignment.Robotic UKA is associated with reduced postoperative pain, decreased opiate analgesia requirements, faster inpatient rehabilitation, and earlier time to hospital discharge compared to conventional manual UKA.Limitations of robotic UKA include high installation costs, additional radiation exposure with image-based systems, and paucity of studies showing any long-term differences in functional outcomes or implant survivorship compared to conventional manual UKA.Further clinical studies are required to establish how statistical differences in accuracy of implant positioning between conventional manual UKA and robotic UKA translate to long-term differences in functional outcomes, implant survivorship, complications, and cost-effectiveness. Cite this article: EFORT Open Rev 2020;5:312-318. DOI: 10.1302/2058-5241.5.190089.

SELECTION OF CITATIONS
SEARCH DETAIL
...