Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-24332521

ABSTRACT

OBJECTIVE: The control of bleeding after tooth extraction is a major concern in patients taking warfarin. Light-emitting diode (LED) irradiation with hemostatic gelatin sponge application was investigated. STUDY DESIGN: Patients who took warfarin and required tooth extraction were divided randomly into 3 groups. The first group was irradiated with blue-violet LED after tooth extraction. The second group was treated with a hemostatic gelatin sponge and LED irradiation. The third group was treated with only hemostatic gelatin sponges. Hemostasis was evaluated at 30 seconds after treatment. RESULTS: Less than 30% of the patients achieved hemostasis within 30 seconds in the hemostatic sponge group; approximately 50% of the patients in the simple LED irradiation group achieved hemostasis within 30 seconds; and 86.7% of the patients in the LED and hemostatic sponge combined group achieved hemostasis within 30 seconds, indicating that combined treatment with LED and hemostatic sponges provided a significantly higher hemostasis than in the hemostatic sponge group (P < .01). CONCLUSIONS: Blue-violet LED irradiation combined with hemostatic gelatin sponge treatment yielded hemostasis of the extraction socket within 30 seconds without suture in most cases.


Subject(s)
Hemostatics/therapeutic use , Oral Hemorrhage/prevention & control , Phototherapy/methods , Postoperative Hemorrhage/prevention & control , Tooth Extraction , Warfarin/administration & dosage , Adult , Aged , Aged, 80 and over , Female , Gelatin/therapeutic use , Humans , Male , Middle Aged , Oral Hemorrhage/etiology , Postoperative Hemorrhage/etiology , Surgical Sponges , Treatment Outcome
2.
Photomed Laser Surg ; 29(5): 333-8, 2011 May.
Article in English | MEDLINE | ID: mdl-21495857

ABSTRACT

OBJECTIVE: Bleeding control is a major concern during dental surgery. A novel photocoagulation method using an irradiating blue-violet light emitting diode (LED) was investigated. BACKGROUND: Some dental light-curving units can emit blue-violet wavelengths around 380-515 nm with two peaks (410 nm and 470 nm). These wavelengths can cover the maximum absorption spectra of hemoglobin (430 nm). MATERIALS AND METHODS: Blue-violet LED 380-515 nm, 750 mW/cm(2), 10 sec (7.5 J/cm(2)) was used. Irradiation was performed for 10 sec or an additional 10 sec for 10 cases of tooth extraction at a distance of 1 cm from the socket. Bleeding was stopped by conventional roll pressure in another five cases as a control. Bleeding time for both procedures was measured. A Mann-Whitney U test was used for statistical analysis. In vitro transmission electron microscope (TEM) studies were performed to clarify the mechanism of hemostasis by blue-violet LED irradiation. RESULTS: Irradiation with the blue-violet LED yielded immediate hemostasis of the socket. Five cases showed coagulation within the first 10 sec, and another five cases required an additional 10 sec to fully control the bleeding. In contrast, the conventional method required 2-5 min (median 180 sec) to obtain hemostasis. The difference between the time required to stop the bleeding in the two methods was found to be statistically significant (p = 0.0014). A week later, the LED-irradiated sockets were healed uneventfully with epithelial covering. TEM showed the formation of a thin amorphous layer and an adjacent agglutination of platelets and other cellular elements under the layer at the interface of the irradiated blood. CONCLUSION: Blue-violet LED irradiation of bleeding sockets caused immediate clot formation and hemostasis. This procedure was safe and reliable and showed no adverse effects.


Subject(s)
Oral Hemorrhage/prevention & control , Phototherapy , Postoperative Hemorrhage/prevention & control , Tooth Extraction/adverse effects , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Oral Hemorrhage/etiology , Postoperative Hemorrhage/etiology , Tooth Socket
3.
Anal Sci ; 20(1): 129-32, 2004 Jan.
Article in English | MEDLINE | ID: mdl-14753270

ABSTRACT

This paper describes a highly sensitive and selective method for the determination of hydroxylated polycyclic aromatic hydrocarbons (PAHs-OH) in airborne particulates. PAHs-OH were extracted from airborne particulates with ethanol by ultrasonication. The extractant was further cleaned up by solid phase extraction (SPE) with an aminopropylsilica cartridge, and subsequently analyzed by reversed-phase high-performance liquid chromatography with fluorescence detection. 2-Hydroxy-1-acetonaphthone was used as an internal standard. By the proposed method, 2-hydroxyfluorene and 1-hydroxypyrene were identified in airborne particulates and their concentrations were determined for the first time.

SELECTION OF CITATIONS
SEARCH DETAIL
...