Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 8(12): e81726, 2013.
Article in English | MEDLINE | ID: mdl-24367491

ABSTRACT

We developed an automated diagnostic system for the detection of virus-specific immunoglobulin Gs (IgGs) that was based on a microarray platform. We compared efficacies of our automated system with conventional enzyme immunoassays (EIAs). Viruses were immobilized to microarrays using a radical cross-linking reaction that was induced by photo-irradiation. A new photoreactive polymer containing perfluorophenyl azide (PFPA) and poly(ethylene glycol) methacrylate was prepared and coated on plates. Inactivated measles, rubella, mumps, Varicella-Zoster and recombinant Epstein-Barr viruse antigen were added to coated plates, and irradiated with ultraviolet light to facilitate immobilization. Virus-specific IgGs in healthy human sera were assayed using these prepared microarrays and the results obtained compared with those from conventional EIAs. We observed high correlation (0.79-0.96) in the results between the automated microarray technique and EIAs. The microarray-based assay was more rapid, involved less reagents and sample, and was easier to conduct compared with conventional EIA techniques. The automated microarray system was further improved by introducing reagent storage reservoirs inside the chamber, thereby conserving the use of expensive reagents and antibodies. We considered the microarray format to be suitable for rapid and multiple serological diagnoses of viral diseases that could be developed further for clinical applications.


Subject(s)
Antibodies, Viral/blood , Oligonucleotide Array Sequence Analysis , Serologic Tests/methods , Azides , Herpesvirus 4, Human/immunology , Humans , Hydrocarbons, Fluorinated , Immunoenzyme Techniques , Immunoglobulin G/blood , Mumps virus/immunology , Rubella virus/immunology
2.
J Biotechnol ; 161(4): 414-21, 2012 Nov 15.
Article in English | MEDLINE | ID: mdl-22921501

ABSTRACT

An automated microarray diagnostic system for specific IgE using photoimmobilized allergen has been developed. Photoimmobilization is useful for preparing microarrays, where various types of biological components are covalently immobilized on a plate. Because the immobilization is based on a photo-induced radical cross-linking reaction, it does not require specific functional groups on the immobilized components. Here, an aqueous solution of a photoreactive poly(ethylene glycol)-based polymer was spin-coated on a plate, and an aqueous solution of each allergen was microspotted on the coated plate and allowed to dry in air. Finally, the plate was irradiated with an ultraviolet lamp for covalent immobilization. An automated machine using these plates was developed for the assay of antigen-specific IgE. Initially, the patient serum was added to the microarray plate, and after reaction of the microspotted allergen with IgE, the adsorbed IgE was detected by a peroxidase-conjugated anti-IgE-antibody. The chemical luminescence intensity of the substrate decomposed by the peroxidase was automatically detected using a sensitive charge-coupled device camera. All the allergens were immobilized stably using this method, which was used to screen for allergen-specific IgE. The results were comparable with those using conventional specific IgE. Using this system, six different allergen-specific IgE were assayed using 10 µL of serum within a period of 20 min.


Subject(s)
Allergens/immunology , Immunoglobulin E/blood , Protein Array Analysis/methods , Adolescent , Adult , Allergens/radiation effects , Azides/chemistry , Child , Child, Preschool , Female , Food Hypersensitivity/blood , Food Hypersensitivity/diagnosis , Food Hypersensitivity/immunology , Humans , Immunoglobulin E/immunology , Infant , Male , Nitriles/chemistry , Polyethylene Glycols/chemistry , Polymethacrylic Acids/chemistry , Ultraviolet Rays , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...