Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
Clin Optom (Auckl) ; 11: 173-180, 2019.
Article in English | MEDLINE | ID: mdl-31920417

ABSTRACT

PURPOSE: In this study densitometry software for the Oculus Pentacam was used to investigate the treatment outcomes of corneal cross linking (CXL) in adult and juvenile keratoconus (KCN) patients. Densitometry measurements were taken before and after treatment and followed up for one year. METHODS: A comparative study was carried out at Manchester Royal Eye Hospital. Corneal densitometry measurements collected before and after CXL treatment for 32 eyes from KC patients, aged between 12 and 39, were divided to 2 groups 13-18 years (juvenile group) and 19-39 years (adult group) and analysed and compared to pre and post treatment at 3, 6 and 12 months for each group and between both groups. RESULTS: Analysis of densitometry measurements found higher corneal densitometry after CXL which peaks at three months post treatment in both groups. There was significant diversity in corneal densitometry measurements in the stromal zone 0-2 and 2-6 mm for all layers except the posterior layer for both groups (P<0.05). Significantly increased densitometry value was found higher in the juvenile group at six months in the central (P=0.006) and posterior (P=0.004) layers for zone 0-2 mm. The same layers differed significantly also in the 2-6 mm zone in all layers (P=0.01). One year post treatment the same significant increased densitometry level was seen in the juvenile group in the 0-2 mm zone of the central (P=0.007) and posterior layers (P=0.01), as was the 2-6 mm zone (P=0.04). However, no significant difference was found between pre and post treatment for best corrected visual acuity (BCVA), central corneal thickness (CCT) and thinnest area between both groups. A significant difference was found between pre and post treatment for best corrected visual acuity (BCVA), in the adult group at 6 and 12 months post-treatment from pre-treatment (P=0.02, P=0.16) respectively. CONCLUSION: Corneal clarity post CXL treatment in the juvenile group differed significantly from the adult group. Both groups showed increased haze at 3 months post treatment but the adults showed improvement over the next 9 months. In contrast, the juvenile group showed higher densitometry readings at both 6 and 12 months post treatment in comparison to adult group. The reasons for this remain unclear.

2.
Clin Ophthalmol ; 12: 1653-1658, 2018.
Article in English | MEDLINE | ID: mdl-30233127

ABSTRACT

AIM: The aim of this study was to compare the pre- and posttreatment corneal densitometry and corneal thickness value of keratoconus (KCN) patients managed via contact lenses (CLs) or by both intrastromal corneal rings and contact lenses. PATIENTS AND METHODS: This prospective study was performed at the Manchester Royal Eye Hospital, UK. Patients were recruited before treatment and followed up for 12 months. Data of corneal densitometry and corneal thickness were collected using the Oculus Pentacam at the pretreatment visit and posttreatment visit at 12 months. RESULTS: Corneal clarity significantly differs between both groups at pre treatment at zone 0-2 mm for the anterior layer (P=0.002). The same diversity is present at zone 2-6 mm for the anterior layer (P=0.003) and posterior layer (P=0.008). The corneal clarity diversity found was not statistically significant at 12 months post treatment (P>0.05). Corneal thickness was found to be statistically significantly different between pre treatment and post treatment for the CL group for central corneal thickness (CCT) and thinnest area (P=0.01 and P=0.02), respectively. DISCUSSION: This study shows that KCN management with Intacs was found to be effective in maintaining corneal clarity for a longer time than that with CL alone. On the other hand, corneal clarity reduces with disease progression in cases managed with CLs only. Analysis of Oculus Pentacam images provides an objective evaluation to monitor the corneal status after these different pathways of management.

3.
Clin Ophthalmol ; 12: 577-585, 2018.
Article in English | MEDLINE | ID: mdl-29615834

ABSTRACT

PURPOSE: To compare the corneal clarity measurement between penetrating keratoplasty (PK) and deep anterior lamellar keratoplasty (DALK) in patients with keratoconus, using densitometry software for the Oculus Pentacam. METHODS: A retrospective comparative study was carried out at Manchester Royal Eye Hospital. Data were collected 12-18 months after corneal transplantation for keratoconus, including postoperative corneal densitometry, best corrected visual acuity (BCVA), central corneal thickness (CCT), and other relevant clinical details. RESULTS: Analysis of 37 keratoconus eyes from 36 patients found there was a significantly higher corneal densitometry measurement after DALK than PK. This was predominantly in the posterior layer of the concentric zone 0-2 mm of the cornea (P=0.0004). A significant correlation was found between postoperative BCVA and corneal densitometry in DALK groups at full thickness (P=0.03). This correlation was seen in the central 0-2 mm (P=0.03) and posterior 0-2 mm (P=0.04) zones. In addition, within the DALK group, a correlation was found between central corneal thickness and densitometry at full thickness 2-6 mm (P=0.007), central 0-2 (P=0.04), central 2-6 mm (P=0.01), and at posterior 2-6 mm (P=0.01) zones. CONCLUSION: This study showed that corneal densitometry measurement differs depending on the type of corneal transplantation used to treat keratoconus patients. Densitometry may have an important role to play in the final BCVA achieved by patients undergoing corneal transplantation for keratoconus. Analysis of Oculus Pentacam images provides an objective evaluation to monitor the cornea status after the surgery.

4.
Clin Ophthalmol ; 11: 2043-2049, 2017.
Article in English | MEDLINE | ID: mdl-29200817

ABSTRACT

PURPOSE: The purpose of this study was to assess UV corneal crosslinking (CXL) treatment outcomes for keratoconus by evaluating the corneal regularity in patients through follow-up using the Oculus Pentacam. PATIENTS AND METHODS: A total of 18 eyes from CXL patients with keratoconus were studied before and after CXL treatment, and six eyes from six patients who were not treated with CXL served as controls. Treated patients had Pentacam images taken before CXL treatment and regularly 3 months post treatment up to the 12th month. Controls were imaged during their first appointment and after 12 months. Symmetry and asphericity were evaluated and correlated with both best-corrected visual acuity (BCVA) and maximum K-readings. RESULTS: In the CXL-treated group, there was a significant improvement in the index of symmetrical variation (ISV) and keratoconus index (KI) at 3 months and in the index of height asymmetry (IHA) and minimum radius of curvature (Rmin) at 9 months post treatment. On the contrary, the untreated group's indices showed some significant worsening in ISV, KI, central keratoconus index (CKI), and Rmin. A novel finding in our study was a slight positive shift of anterior asphericity in the 6 mm, 7 mm, and 8 mm 3 months after treatment, which had a correlation with BCVA (R2=0.390, p=0.053) and a strong correlation with maximum K-reading (R2=0.690, p=0.005). However, the untreated group had no significant changes after 1 year. CONCLUSION: The corneal asymmetrical shape is associated with the spherical aberration alteration influenced by temporal evolution of surface ablation and increased corneal haze. However, insignificant changes in symmetry attest the stabilization effect on cornea postoperatively as compared with controls.

5.
Medicine (Baltimore) ; 96(46): e8563, 2017 Nov.
Article in English | MEDLINE | ID: mdl-29145265

ABSTRACT

The aim of this study was to standardize and investigate the changes in corneal clarity with age. Densitometry software for the Oculus Pentacam was used to examine corneal clarity at different age groups.A total of 192 eyes from 97 healthy participants were included in this cohort comparative nonrandomized, cross-sectional study. An Oculus Pentcam was used to image the cornea of healthy participants grouped by age (between 10 and 70 years old). Data from the densitometry output have been used to determine clarity in concentric zones and different depths of the cornea.Corneal densitometry (CD) across all ages showed significant differences between groups when divided into the following layers: anterior, central, and posterior or divided into 0 to 2, 2 to 6, and 6 to 10 mm concentric zones (P < .05). The most striking decrease in clarity occurred with age in all 3 layers of the periphery (6-10 mm) (P < .05). In addition, we showed that the 10 to 19-year age group had lower clarity than the 20 to 30-age group (P < .05), and after 30 years, the cornea shows a steady progression of increased or decreased clarity.The values for CD, as well as for separate subdivisions based on layer and surface area, might provide a standard for use in further studies and clinical practice. This study established that relation between CD and age is differed when the cornea is divided into layers and zones. This study suggests that there are other factors that may play an essential role in corneal clarity as well as age.


Subject(s)
Cornea/anatomy & histology , Adolescent , Adult , Age Factors , Aged , Child , Cross-Sectional Studies , Densitometry , Female , Humans , Male , Middle Aged , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...