Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Radiat Oncol Biol Phys ; 84(2): e173-9, 2012 Oct 01.
Article in English | MEDLINE | ID: mdl-22857886

ABSTRACT

PURPOSE: To evaluate, using real-time monitoring of implanted radiofrequency transponders, the intrafraction prostate displacement of patients as a function of body mass index (BMI). METHODS AND MATERIALS: The motions of Beacon radiofrequency transponders (Calypso Medical Technologies, Seattle, WA) implanted in the prostate glands of 66 men were monitored throughout the course of intensity modulated radiation therapy. Data were acquired at 10 Hz from setup to the end of treatment, but only the 1.7 million data points with a "beam on" tag were used in the analysis. There were 21 obese patients, with BMI ≥ 30 and 45 nonobese patients in the study. RESULTS: Mean displacements were least in the left-right lateral direction (0.56 ± 0.24 mm) and approximately twice that magnitude in the superior-inferior and anterior-posterior directions. The net vector displacement was larger still, 1.95 ± 0.47 mm. Stratified by BMI cohort, the mean displacements per patient in the 3 Cartesian axes as well as the net vector for patients with BMI ≥ 30 were slightly less (<0.2 mm) but not significantly different than the corresponding values for patients with lower BMIs. As a surrogate for the magnitude of oscillatory noise, the standard deviation for displacements in all measured planes showed no significant differences in the prostate positional variability between the lower and higher BMI groups. Histograms of prostate displacements showed a lower frequency of large displacements in obese patients, and there were no significant differences in short-term and long-term velocity distributions. CONCLUSIONS: After patients were positioned accurately using implanted radiofrequency transponders, the intrafractional displacements in the lateral, superior-inferior, and anterior-posterior directions as well as the net vector displacements were smaller, but not significantly so, for obese men than for those with lower BMI.


Subject(s)
Body Mass Index , Electromagnetic Fields , Movement , Prostate , Prostatic Neoplasms/radiotherapy , Aged , Biomechanical Phenomena/physiology , Fiducial Markers , Humans , Male , Obesity/complications , Organ Size , Patient Positioning/methods , Prostate/pathology , Prostatic Neoplasms/pathology , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...