Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
2.
Fertil Steril ; 81(1): 93-8, 2004 Jan.
Article in English | MEDLINE | ID: mdl-14711549

ABSTRACT

OBJECTIVE: To clarify a potential therapeutic role of coenzyme Q(10) (CoQ(10)) in infertile men with idiopathic asthenozoospermia. DESIGN: Open, uncontrolled pilot study. PATIENT(S): Infertile men with idiopathic asthenozoospermia. INTERVENTION(S): CoQ(10) was administered orally; semen samples were collected at baseline and after 6 months of therapy. MAIN OUTCOME MEASURE (S): Semen kinetic parameters, including computer-assisted sperm data and CoQ(10) and phosphatidylcholine levels. RESULT(S): CoQ(10) levels increased significantly in seminal plasma and in sperm cells after treatment. Phosphatidylcholine levels also increased. A significant increase was also found in sperm cell motility as confirmed by computer-assisted analysis. A positive dependence (using the Cramer's index of association) was evident among the relative variations, baseline and after treatment, of seminal plasma or intracellular CoQ(10) content and computer-determined kinetic parameters. CONCLUSION(S): The exogenous administration of CoQ(10) may play a positive role in the treatment of asthenozoospermia. This is probably the result of its role in mitochondrial bioenergetics and its antioxidant properties.


Subject(s)
Oligospermia/drug therapy , Semen/drug effects , Ubiquinone/analogs & derivatives , Ubiquinone/therapeutic use , Adult , Coenzymes , Dietary Supplements , Female , Humans , Infertility, Male/drug therapy , Male , Phosphatidylcholines/metabolism , Pregnancy , Pregnancy Rate , Semen/metabolism , Sperm Count , Treatment Outcome
3.
Anal Biochem ; 305(1): 49-54, 2002 Jun 01.
Article in English | MEDLINE | ID: mdl-12018945

ABSTRACT

A new method is described for determining coenzyme Q(10) (CoQ(10)) in plasma. The method is based on oxidation of CoQ(10) in the sample by treating it with para-benzoquinone followed by extraction with 1-propanol and direct injection into the HPLC apparatus. This method achieves a linear detector response for peak area measurements over the concentration range of 0.05-3.47 microM. Diode array analysis of the peak was consistent with CoQ(10) spectrum. Supplementation of the samples with known amounts of CoQ(10) yielded a quantitative recovery of 96-98.5%; the method showed a level of quantitation of 1.23 nmol per HPLC injection (200 microl of propanol extract containing 33.3 microl of plasma). A correlation of r = 0.99 (P < 0.0001) was found with a reference electrochemical detection method. Within run precision showed a CV% of 1.6 for samples approaching normal values (1.02 microM). Day-to-day precision was also close to 2%.


Subject(s)
Ubiquinone/analogs & derivatives , Ubiquinone/blood , Benzoquinones/chemistry , Calibration , Centrifugation , Chromatography, High Pressure Liquid/methods , Coenzymes , Electrochemistry/methods , Enzyme Stability , Humans , Indicator Dilution Techniques , Linear Models , Oxidation-Reduction , Reproducibility of Results , Sensitivity and Specificity , Spectrophotometry, Ultraviolet
SELECTION OF CITATIONS
SEARCH DETAIL
...