Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 143
Filter
1.
Front Physiol ; 15: 1327407, 2024.
Article in English | MEDLINE | ID: mdl-38384795

ABSTRACT

Introduction: Magnetic resonance elastography (MRE) is a non-invasive method to quantify biomechanical properties of human tissues. It has potential in diagnosis and monitoring of kidney disease, if established in clinical practice. The interplay of flow and volume changes in renal vessels, tubule, urinary collection system and interstitium is complex, but physiological ranges of in vivo viscoelastic properties during fasting and hydration have never been investigated in all gross anatomical segments simultaneously. Method: Ten healthy volunteers underwent two imaging sessions, one following a 12-hour fasting period and the second after a drinking challenge of >10 mL per kg body weight (60-75 min before the second examination). High-resolution renal MRE was performed using a novel driver with rotating eccentric mass placed at the posterior-lateral wall to couple waves (50 Hz) to the kidney. The biomechanical parameters, shear wave speed (cs in m/s), storage modulus (Gd in kPa), loss modulus (Gl in kPa), phase angle (Υ=2πatanGlGd) and attenuation (α in 1/mm) were derived. Accurate separation of gross anatomical segments was applied in post-processing (whole kidney, cortex, medulla, sinus, vessel). Results: High-quality shear waves coupled into all gross anatomical segments of the kidney (mean shear wave displacement: 163 ± 47 µm, mean contamination of second upper harmonics <23%, curl/divergence: 4.3 ± 0.8). Regardless of the hydration state, median Gd of the cortex and medulla (0.68 ± 0.11 kPa) was significantly higher than that of the sinus and vessels (0.48 ± 0.06 kPa), and consistently, significant differences were found in cs, Υ, and Gl (all p < 0.001). The viscoelastic parameters of cortex and medulla were not significantly different. After hydration sinus exhibited a small but significant reduction in median Gd by -0.02 ± 0.04 kPa (p = 0.01), and, consequently, the cortico-sinusoidal-difference in Gd increased by 0.04 ± 0.07 kPa (p = 0.05). Only upon hydration, the attenuation in vessels became lower (0.084 ± 0.013 1/mm) and differed significantly from the whole kidney (0.095 ± 0.007 1/mm, p = 0.01). Conclusion: High-resolution renal MRE with an innovative driver and well-defined 3D segmentation can resolve all renal segments, especially when including the sinus in the analysis. Even after a prolonged hydration period the approach is sensitive to small hydration-related changes in the sinus and in the cortico-sinusoidal-difference.

2.
J Clin Med ; 12(20)2023 Oct 13.
Article in English | MEDLINE | ID: mdl-37892639

ABSTRACT

The amygdala contains androgen receptors and is involved in various affective and social functions. An interaction between testosterone and the amygdala's functioning is likely. We investigated the amygdala's resting-state functional connectivity (rsFC) network in association with testosterone in 94 healthy young adult women and men (final data available for analysis from 42 women and 39 men). Across the whole sample, testosterone was positively associated with the rsFC between the right amygdala and the right middle occipital gyrus, and it further predicted lower agreeableness scores. Significant sex differences appeared for testosterone and the functional connectivity between the right amygdala and the right superior frontal gyrus (SFG), showing higher testosterone levels with lower connectivity in women. Sex further predicted the openness and agreeableness scores. Our results show that testosterone modulates the rsFC between brain areas involved in affective processing and executive functions. The data indicate that the cognitive control of the amygdala via the frontal cortex is dependent on the testosterone levels in a sex-specific manner. Testosterone seems to express sex-specific patterns (1) in networks processing affect and cognition, and (2) in the frontal down-regulation of the amygdala. The sex-specific coupling between the amygdala and the frontal cortex in interaction with the hormone levels may drive sex-specific differences in a variety of behavioral phenomena that are further associated with psychiatric illnesses that show sex-specific prevalence rates.

3.
J Clin Med ; 12(3)2023 Jan 22.
Article in English | MEDLINE | ID: mdl-36769521

ABSTRACT

Females and males differ in stress reactivity, coping, and the prevalence rates of stress-related disorders. According to a neurocognitive framework of stress coping, the functional connectivity between the amygdala and frontal regions (including the dorsolateral prefrontal cortex (dlPFC), ventral anterior cingulate cortex (vACC), and medial prefrontal cortex (mPFC)) plays a key role in how people deal with stress. In the current study, we investigated the effects of sex and stressor type in a within-subject counterbalanced design on the resting-state functional connectivity (rsFC) of the amygdala and these frontal regions in 77 healthy participants (40 females). Both stressor types led to changes in subjective ratings, with decreasing positive affect and increasing negative affect and anger. Females showed higher amygdala-vACC and amygdala-mPFC rsFC for social exclusion than for achievement stress, and compared to males. Whereas a higher amygdala-vACC rsFC indicates the activation of emotion processing and coping, a higher amygdala-mPFC rsFC indicates feelings of reward and social gain, highlighting the positive effects of social affiliation. Thus, for females, feeling socially affiliated might be more fundamental than for males. Our data indicate interactions of sex and stressor in amygdala-frontal coupling, which translationally contributes to a better understanding of the sex differences in prevalence rates and stress coping.

5.
Med Phys ; 49(4): 2366-2372, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35224747

ABSTRACT

BACKGROUND: MR-based methods for attenuation correction (AC) in PET/MRI either neglect attenuation of bone, or use MR-signal derived information about bone, which leads to a bias in quantification of tracer uptake in PET. In a previous study, we presented a PET/MRI specific MR coil with an integrated transmission source (TX) system allowing for direct measurement of attenuation. In phantom measurements, this system successfully reproduced the linear attenuation coefficient of water. PURPOSE: The purpose of this study is to validate the TX system in a clinical setting using animals and to show its applicability compared to standard clinical methods. METHODS: As test subject, a 15-kg piglet was injected with 53 MBq of 18F-NaF. The µ-map obtained with the TX system and the reconstructed activity distribution were compared to four established AC methods: a Dixon sequence, an ultra-short echo time (UTE) sequence, a CT scan, and a 511 keV transmission scan using a Siemens ECAT EXACT HR+ as the reference. The PET/MRI measurements were performed on a Siemens Biograph mMR to obtain the µ-map using the TX system as well as the Dixon and UTE sequence directly followed by the CT and ECAT measurements. RESULTS: The reconstructed activity distribution using the TX system for AC showed similar results compared to the reference (<5% difference in hot regions) and outperformed the MR-based methods as implemented in the PET/MRI system (<10% difference in hot regions). However, the additional hardware of the TX system adds complexity to the acquisition process. CONCLUSION: Our porcine study demonstrates the feasibility of post-injection transmission scans using the developed TX system in a clinical setting. This makes it a useful tool for PET/MRI in cases where transmission information is needed for AC. Potential applications are studies using larger animals where state-of-the-art atlas-based or artificial intelligence AC methods are not available.


Subject(s)
Artificial Intelligence , Multimodal Imaging , Animals , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Multimodal Imaging/methods , Phantoms, Imaging , Positron-Emission Tomography/methods , Swine
6.
J Med Case Rep ; 16(1): 13, 2022 Jan 15.
Article in English | MEDLINE | ID: mdl-35031059

ABSTRACT

BACKGROUND: Fenestration of the cervical segment of the internal carotid artery is a very rare finding, and its origin is still not fully understood. Explanations of its genesis range from dissections leading to the fenestration to the more common interpretation as a developmental vascular variant. However, most reported cases were symptomatic and presented with dissections, where even endovascular treatment of the fenestration of the cervical segment of the internal carotid artery became necessary. Here we report a case of a fenestration of the cervical segment of the internal carotid artery suffering a transitory ischemic attack and local pain in absence of any sign of dissection. CASE PRESENTATION: A 62-year-old Caucasian male patient was admitted to our institution because of an episode of amaurosis fugax, initially accompanied with headache. Magnetic resonance imaging revealed an intact fenestration of the cervical segment of the internal carotid artery on the symptomatic side. With antiplatelet therapy, all symptoms vanished within 2 months of the initial event. CONCLUSIONS: Our findings support the interpretation of a fenestration of the cervical segment of the internal carotid artery as a developmental vascular variant, but also suggest a substantial risk for dissection and ischemic stroke. Even in case of an accidental finding, clinicians should be aware of this. At least in this case, antiplatelet therapy seemed beneficial.


Subject(s)
Carotid Artery, Internal, Dissection , Ischemic Attack, Transient , Stroke , Carotid Artery, Internal/diagnostic imaging , Carotid Artery, Internal/surgery , Carotid Artery, Internal, Dissection/diagnostic imaging , Humans , Ischemic Attack, Transient/etiology , Magnetic Resonance Imaging , Male , Middle Aged , Stroke/diagnostic imaging , Stroke/etiology
7.
Magn Reson Med ; 87(3): 1174-1183, 2022 03.
Article in English | MEDLINE | ID: mdl-34719061

ABSTRACT

PURPOSE: Lactate is a key metabolite in skeletal muscle and whole-body physiology. Its MR visibility in muscle is affected by overlapping lipid signals and fiber orientation. Double-quantum filtered (DQF) 1 H MRS selectively detects lactate at 1.3 ppm, but at ultra-high field the efficiency of slice-selective 3D-localization with conventional RF pulses is limited by bandwidth. This novel 3D-localized 1 H DQF MRS sequence uses adiabatic refocusing pulses to unambiguously detect lactate in skeletal muscle at 7 T. METHODS: Lactate double-quantum coherences were 3D-localized using slice-selective Shinnar-Le Roux optimized excitation and adiabatic refocusing pulses (similar to semi-LASER). DQF MR spectra were acquired at 7 T from lactate phantoms, meat specimens with injected lactate (exploring multiple TEs and fiber orientations), and human gastrocnemius in vivo during and after exercise (without cuff ischemia). RESULTS: Lactate was readily detected, achieving the full potential of 50% signal with a DQF, in solution. The effects of fiber orientation and TE on the lactate doublet (peak splitting, amplitude, and phase) were in good agreement with theory and literature. Exercise-induced lactate accumulation was detected with 30 s time resolution. CONCLUSION: This novel 3D-localized 1 H DQF MRS sequence can dynamically detect glycolytically generated lactate in muscle during exercise and recovery at 7 T.


Subject(s)
Lactic Acid , Muscle, Skeletal , Exercise , Humans , Magnetic Resonance Spectroscopy , Muscle, Skeletal/diagnostic imaging , Phantoms, Imaging
8.
Sci Rep ; 10(1): 19568, 2020 11 11.
Article in English | MEDLINE | ID: mdl-33177570

ABSTRACT

The profiles of time-contrast (TC) -curves from popular MRI injectors derived at the injection site of the attached tube-line system were compared. Variations of TC-profiles were previously reported to potentially influence image quality in time critical MRI measurements. TC-curves from five injectors obtained during commonly used injection protocols were assessed according to representative quality criteria: (1) correlation strength between a fitted boxcar function and the TC-curve (cBCF) and (2) difference between true and expected injection time (dBIT). Additionally, the impact from technical injector properties: pump type, line volume, maximum injection power and type of contrast medium (CM) on the TC-profiles was evaluated. Injectors using a piston-syrinx (PS) mechanism for CM-injection performed significantly better than those working with a peristaltic roller pump (RP) technique. Besides injection mechanism, line filling volume showed a strong influence on the final TC-curves, where larger filling volumes induced worse cBCF- and dBIT-results. Therefore, to achieve an optimal bolus in clinical MRI use of a PS-injector seems recommendable. Besides their pump mechanism, RP-injectors appeared additionally hampered by their high volume line systems, pointing out an unfavourable coinicidence of these technical features in RP-injectors. This should be considered, particularly, in comparative or time-critical MRI-studies.

9.
Magn Reson Med ; 83(6): 1909-1919, 2020 06.
Article in English | MEDLINE | ID: mdl-31846116

ABSTRACT

PURPOSE: MR offers the unique possibility to noninvasively investigate cellular energy metabolism via 31P MRS, while blood perfusion, which provides oxygen and substrates to the tissue, is accessible by arterial spin labeling (ASL) 1H MRI. Because metabolic and hemodynamic parameters are linked, it would be desirable to study them simultaneously. A 3D-resolved method is presented that allows such measurements with high spatiotemporal resolution and has the potential to discern differences along an exercising muscle. METHODS: Multi-voxel localized 31 P MRS was temporally interleaved with multi-slice pASL 1H MRI. Phosphorus spectra were collected from two adjacent positions in gastrocnemius medialis (GM) during rest, submaximal plantar flexion exercise and recovery, while perfusion and T2* -weighted axial images were acquired at the same time. Seventeen healthy volunteers (9 f / 8 m) were studied at 7 T. RESULTS: An increase of postexercise perfusion and T2* -weighted signal in GM positively correlated with end-exercise PCr depletion and pH drop. At proximal positions functional and metabolic activity was higher than distally, that is, perfusion increase and peak T2* -weighted signal, end-exercise PCr depletion, end-exercise pH, and PCr recovery time constant were significantly different. An NOE-induced SNR increase of approximately 20 % (P < .001), at rest, was found in interleaved 31 P spectra, when comparing to 31 P-only acquisitions. CONCLUSIONS: A technique for fast, simultaneous imaging of muscle functional heterogeneity in ASL, T2* and acquisition of time-resolved 31 P  MRS data is presented. These single exercise recovery experiments can be used to investigate local variations during disease progression in patients suffering from vascular or muscular diseases.


Subject(s)
Leg , Muscle, Skeletal , Exercise , Humans , Leg/diagnostic imaging , Magnetic Resonance Imaging , Muscle, Skeletal/diagnostic imaging , Phosphocreatine
10.
Sensors (Basel) ; 19(15)2019 07 26.
Article in English | MEDLINE | ID: mdl-31357545

ABSTRACT

The goal of this work is to further improve positron emission tomography (PET) attenuation correction and magnetic resonance (MR) sensitivity for head and neck applications of PET/MR. A dedicated 24-channel receive-only array, fully-integrated with a hydraulic system to move a transmission source helically around the patient and radiofrequency (RF) coil array, is designed, implemented, and evaluated. The device enables the calculation of attenuation coefficients from PET measurements at 511 keV including the RF coil and the particular patient. The RF coil design is PET-optimized by minimizing photon attenuation from coil components and housing. The functionality of the presented device is successfully demonstrated by calculating the attenuation map of a water bottle based on PET transmission measurements; results are in excellent agreement with reference values. It is shown that the device itself has marginal influence on the static magnetic field B0 and the radiofrequency transmit field B1 of the 3T PET/MR system. Furthermore, the developed RF array is shown to outperform a standard commercial 16-channel head and neck coil in terms of signal-to-noise ratio (SNR) and parallel imaging performance. In conclusion, the presented hardware enables accurate calculation of attenuation maps for PET/MR systems while improving the SNR of corresponding MR images in a single device without degrading the B0 and B1 homogeneity of the scanner.


Subject(s)
Head/diagnostic imaging , Magnetic Resonance Imaging/methods , Neck/diagnostic imaging , Positron-Emission Tomography/methods , Humans , Image Processing, Computer-Assisted , Multimodal Imaging , Phantoms, Imaging , Radio Waves , Signal-To-Noise Ratio
11.
Transl Psychiatry ; 9(1): 64, 2019 02 04.
Article in English | MEDLINE | ID: mdl-30718459

ABSTRACT

Due to lacking predictors of depression recovery, successful treatment of major depressive disorder (MDD) is frequently only achieved after therapeutic optimization leading to a prolonged suffering of patients. This study aimed to determine neural prognostic predictors identifying non-remitters prior or early after treatment initiation. Moreover, it intended to detect time-sensitive neural mediators indicating depression recovery. This longitudinal, interventional, single-arm, open-label, phase IV, pharmacological functional magnetic resonance imaging (fMRI) study comprised four scans at important stages prior (day 0) and after escitalopram treatment initiation (day 1, 28, and 56). Totally, 22 treatment-free MDD patients (age mean ± SD: 31.5 ± 7.7; females: 50%) suffering from a concurrent major depressive episode without any comorbid DSM-IV axis I diagnosis completed the study protocol. Primary outcome were neural prognostic predictors of depression recovery. Enhanced de-activation of anterior medial prefrontal cortex (amPFC, single neural mediator) indicated depression recovery correlating with MADRS score and working memory improvements. Strong dorsolateral PFC (dlPFC) activation and weak dlPFC-amPFC, dlPFC-posterior cingulate cortex (PCC), dlPFC-parietal lobe (PL) coupling (three prognostic predictors) hinted at depression recovery at day 0 and 1. Preresponse prediction of continuous (dlPFC-PL: R2day1 = 55.9%, 95% CI: 22.6-79%, P < 0.005) and dichotomous (specificity/sensitivity: SP/SNday1 = 0.91/0.82) recovery definitions remained significant after leave-one-out cross-validation. Identified prefrontal neural predictors might propel the future development of fMRI markers for clinical decision making, which could lead to increased response rates and adherence during acute phase treatment periods. Moreover, this study underscores the importance of the amPFC in depression recovery.


Subject(s)
Citalopram/pharmacology , Connectome/standards , Depressive Disorder, Major , Memory, Short-Term , Nerve Net , Outcome Assessment, Health Care/standards , Prefrontal Cortex , Selective Serotonin Reuptake Inhibitors/pharmacology , Adult , Connectome/methods , Depressive Disorder, Major/diagnostic imaging , Depressive Disorder, Major/drug therapy , Depressive Disorder, Major/physiopathology , Female , Gyrus Cinguli/diagnostic imaging , Gyrus Cinguli/drug effects , Gyrus Cinguli/physiopathology , Humans , Longitudinal Studies , Magnetic Resonance Imaging , Male , Memory, Short-Term/drug effects , Memory, Short-Term/physiology , Nerve Net/diagnostic imaging , Nerve Net/drug effects , Nerve Net/physiopathology , Outcome Assessment, Health Care/methods , Parietal Lobe/diagnostic imaging , Parietal Lobe/drug effects , Parietal Lobe/physiopathology , Prefrontal Cortex/diagnostic imaging , Prefrontal Cortex/drug effects , Prefrontal Cortex/physiopathology , Prognosis , Sensitivity and Specificity , Young Adult
12.
Prog Nucl Magn Reson Spectrosc ; 109: 1-50, 2018 12.
Article in English | MEDLINE | ID: mdl-30527132

ABSTRACT

Magnetic resonance imaging and spectroscopic techniques are widely used in humans both for clinical diagnostic applications and in basic research areas such as cognitive neuroimaging. In recent years, new human MR systems have become available operating at static magnetic fields of 7 T or higher (≥300 MHz proton frequency). Imaging human-sized objects at such high frequencies presents several challenges including non-uniform radiofrequency fields, enhanced susceptibility artifacts, and higher radiofrequency energy deposition in the tissue. On the other side of the scale are gains in signal-to-noise or contrast-to-noise ratio that allow finer structures to be visualized and smaller physiological effects to be detected. This review presents an overview of some of the latest methodological developments in human ultra-high field MRI/MRS as well as associated clinical and scientific applications. Emphasis is given to techniques that particularly benefit from the changing physical characteristics at high magnetic fields, including susceptibility-weighted imaging and phase-contrast techniques, imaging with X-nuclei, MR spectroscopy, CEST imaging, as well as functional MRI. In addition, more general methodological developments such as parallel transmission and motion correction will be discussed that are required to leverage the full potential of higher magnetic fields, and an overview of relevant physiological considerations of human high magnetic field exposure is provided.


Subject(s)
Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy/methods , Neuroimaging/methods , Humans
13.
PLoS One ; 13(11): e0206963, 2018.
Article in English | MEDLINE | ID: mdl-30383832

ABSTRACT

PURPOSE: The purpose of this work is the design, implementation and evaluation of a mechanically flexible receive-only coil array for magnetic resonance imaging (MRI) at 3 T that can be applied to various target organs and provides high parallel imaging performance. METHODS: A 23-channel array was designed based on a rigid-flex printed circuit board (PCB). The flexible multi-layer part contains the copper traces forming the coil elements. The rigid part of the PCB houses the solder joints and lumped elements. The coil housing consists of rigid caps mounted above the rigid parts. Adhesive PTFE sheets cover all flexible parts. The developed array was tested on the bench as well as in phantom and in vivo MRI experiments employing parallel imaging acceleration factors up to six. RESULTS: Efficient mutual decoupling between receive elements and detuning between receive array and body coil was achieved. An increased signal-to-noise ratio in comparison to commercial reference coils is demonstrated, especially in regions close to the developed array and for high parallel imaging acceleration factors. Exemplary in vivo images of head, ankle, knee, shoulder and hand are presented. CONCLUSION: Based on high sensitivity close to the array and low g-factors, this flexible coil is well suited for studies of occipital and temporal cortex, as well as musculoskeletal targets like knee, ankle, elbow and wrist.


Subject(s)
Equipment Design , Magnetic Resonance Imaging , Brain/diagnostic imaging , Humans , Joints/diagnostic imaging , Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging/standards , Phantoms, Imaging
14.
J Magn Reson ; 296: 47-59, 2018 11.
Article in English | MEDLINE | ID: mdl-30205313

ABSTRACT

A flexible transceiver array based on transmission line resonators (TLRs) combining the advantages of coil arrays with the possibility of form-fitting targeting cardiac MRI at 7 T is presented. The design contains 12 elements which are fabricated on a flexible substrate with rigid PCBs attached on the center of each element to place the interface components, i.e. transmit/receive (T/R) switch, power splitter, pre-amplifier and capacitive tuning/matching circuitry. The mutual coupling between elements is cancelled using a decoupling ring-based technique. The performance of the developed array is evaluated by 3D electromagnetic simulations, bench tests, and MR measurements using phantoms. Efficient inter-element decoupling is demonstrated in flat configuration on a box-shaped phantom (Sij < -19 dB), and bent on a human torso phantom (Sij < -16 dB). Acceleration factors up to 3 can be employed in bent configuration with reasonable g-factors (<1.7) in an ROI at the position of the heart. The array enables geometrical conformity to bodies within a large range of size and shape and is compatible with parallel imaging and parallel transmission techniques.


Subject(s)
Magnetic Resonance Imaging/instrumentation , Computer Simulation , Electromagnetic Fields , Heart/diagnostic imaging , Humans , Image Enhancement , Phantoms, Imaging , Radio Waves , Signal-To-Noise Ratio , Torso/diagnostic imaging
15.
Nephrol Dial Transplant ; 33(suppl_2): ii41-ii50, 2018 09 01.
Article in English | MEDLINE | ID: mdl-30137583

ABSTRACT

This systematic review, initiated by the European Cooperation in Science and Technology Action Magnetic Resonance Imaging Biomarkers for Chronic Kidney Disease (PARENCHIMA), focuses on potential clinical applications of magnetic resonance imaging in renal non-tumour disease using magnetic resonance relaxometry (MRR), specifically, the measurement of the independent quantitative magnetic resonance relaxation times T1 and T2 at 1.5 and 3Tesla (T), respectively. Healthy subjects show a distinguishable cortico-medullary differentiation (CMD) in T1 and a slight CMD in T2. Increased cortical T1 values, that is, reduced T1 CMD, were reported in acute allograft rejection (AAR) and diminished T1 CMD in chronic allograft rejection. However, ambiguous findings were reported and AAR could not be sufficiently differentiated from acute tubular necrosis and cyclosporine nephrotoxicity. Despite this, one recent quantitative study showed in renal transplants a direct correlation between fibrosis and T1 CMD. Additionally, various renal diseases, including renal transplants, showed a moderate to strong correlation between T1 CMD and renal function. Recent T2 studies observed increased values in renal transplants compared with healthy subjects and in early-stage autosomal dominant polycystic kidney disease (ADPKD), which could improve diagnosis and progression assessment compared with total kidney volume alone in early-stage ADPKD. Renal MRR is suggested to be sensitive to renal perfusion, ischaemia/oxygenation, oedema, fibrosis, hydration and comorbidities, which reduce specificity. Due to the lack of standardization in patient preparation, acquisition protocols and adequate patient selection, no widely accepted reference values are currently available. Therefore this review encourages efforts to optimize and standardize (multi-parametric) protocols to increase specificity and to tap the full potential of renal MRR in future research.


Subject(s)
Biomarkers/analysis , Kidney Diseases/pathology , Kidney/physiopathology , Magnetic Resonance Imaging/methods , Practice Guidelines as Topic/standards , Disease Progression , Humans
16.
NMR Biomed ; 31(6): e3905, 2018 06.
Article in English | MEDLINE | ID: mdl-29578260

ABSTRACT

Exercise studies investigating the metabolic response of calf muscles using 31 P MRS are usually performed with a single knee angle. However, during natural movement, the distribution of workload between the main contributors to force, gastrocnemius and soleus is influenced by the knee angle. Hence, it is of interest to measure the respective metabolic response of these muscles to exercise as a function of knee angle using localized spectroscopy. Time-resolved multivoxel 31 P MRS at 7 T was performed simultaneously in gastrocnemius medialis and soleus during rest, plantar flexion exercise and recovery in 12 healthy volunteers. This experiment was conducted with four different knee angles. PCr depletions correlated negatively with knee angle in gastrocnemius medialis, decreasing from 79±14 % (extended leg) to 35±23 %(∼40°), and positively in soleus, increasing from 20±21 % to 36±25 %; differences were significant. Linear correlations were found between knee angle and end-exercise PCr depletions in gastrocnemius medialis (R2 =0.8) and soleus (R2 =0.53). PCr recovery times and end-exercise pH changes that correlated with PCr depletion were consistent with the literature in gastrocnemius medialis and differences between knee angles were significant. These effects were less pronounced in soleus and not significant for comparable PCr depletions. Maximum oxidative capacity calculated for all knee angles was in excellent agreement with the literature and showed no significant changes between different knee angles. In conclusion, these findings confirm that plantar flexion exercise with a straight leg is a suitable paradigm, when data are acquired from gastrocnemius only (using either localized MRS or small surface coils), and that activation of soleus requires the knee to be flexed. The present study comprises a systematic investigation of the effects of the knee angle on metabolic parameters, measured with dynamic multivoxel 31 P MRS during muscle exercise and recovery, and the findings should be used in future study design.


Subject(s)
Exercise/physiology , Knee Joint/physiology , Magnetic Resonance Spectroscopy , Phosphorus/chemistry , Range of Motion, Articular/physiology , Adult , Female , Humans , Hydrogen-Ion Concentration , Linear Models , Male , Oxidation-Reduction , Phosphocreatine/metabolism
17.
Magn Reson Med ; 79(1): 588-592, 2018 Jan.
Article in English | MEDLINE | ID: mdl-28295563

ABSTRACT

PURPOSE: To demonstrate a dedicated setup for ultrahigh resolution MR imaging of the human finger in vivo. METHODS: A radiofrequency coil was designed for optimized signal homogeneity and sensitivity in the finger at ultrahigh magnetic field strength (7 T), providing high measurement sensitivity. Imaging sequences (2D turbo-spin echo (TSE) and 3D magnetization-prepared rapid acquisition gradient echo (MPRAGE)) were adapted for high spatial resolution and good contrast of different tissues in the finger, while keeping acquisition time below 10 minutes. Data was postprocessed to display finger structures in three dimensions. RESULTS: 3D MPRAGE data with isotropic resolution of 200 µm, along with 2D TSE images with in-plane resolutions of 58 × 78 µm2 and 100 × 97 µm2 , allowed clear identification of various anatomical features such as bone and bone marrow, tendons and annular ligaments, cartilage, arteries and veins, nerves, and Pacinian corpuscles. CONCLUSION: Using this dedicated finger coil at 7 T, together with adapted acquisition sequences, it is possible to depict the internal structures of the human finger in vivo within patient-compatible measurement time. It may serve as a tool for diagnosis and treatment monitoring in pathologies ranging from inflammatory or erosive joint diseases to injuries of tendons and ligaments to nervous or vascular disorders in the finger. Magn Reson Med 79:588-592, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Subject(s)
Fingers/diagnostic imaging , Magnetic Resonance Imaging , Computer Simulation , Humans , Imaging, Three-Dimensional , Magnetic Resonance Spectroscopy , Models, Anatomic , Phantoms, Imaging , Radio Waves , Signal-To-Noise Ratio
18.
Front Physiol ; 9: 1945, 2018.
Article in English | MEDLINE | ID: mdl-30697166

ABSTRACT

Purpose: Perfusion magnetic resonance imaging (P-MRI) is part of the mismatch concept employed for therapy decisions in acute ischemic stroke. Using dynamic susceptibility contrast (DSC) MRI the time-to-maximum (Tmax) parameter is quite popular, but its inconsistently defined computation, arterial input function (AIF) selection, and the applied deconvolution method may introduce bias into the assessment. Alternatively, parameter free methods, namely, standardized time-to-peak (stdTTP), zf-score, and standardized-zf (stdZ) are also available, offering consistent calculation procedures without the need of an AIF or deconvolution. Methods: Tmax was compared to stdTTP, zf-, and stdZ to evaluate robustness of infarct volume estimation in 66 patients, using data from two different sites and MR systems (i.e., 1.5T vs. 3T; short TR (= 689 ms) vs. medium TR (= 1,390 ms); bolus dose 0.1 or 0.2 ml/kgBW, respectively). Results: Quality factors (QF) for Tmax were 0.54 ± 0.18 (sensitivity), 0.90 ± 0.06 (specificity), and 0.87 ± 0.05 (accuracy). Though not significantly different, best specificity (0.93 ± 0.05) and accuracy (0.90 ± 0.04) were found for stdTTP with a sensitivity of 0.56 ± 0.17. Other tested parameters performed not significantly worse than Tmax and stdTTP, but absolute values of QFs were slightly lower, except for zf showing the highest sensitivity (0.72 ± 0.16). Accordingly, in ROC-analysis testing the parameter performance to predict the final infarct volume, stdTTP and zf showed the best performance. The odds for stdTTP to obtain the best prediction of the final infarct size, was 6.42 times higher compared to all other parameters (odds-ratio test; p = 2.2*10-16). Conclusion: Based on our results, we suggest to reanalyze data from large cohort studies using the parameters presented here, particularly stdTTP and zf-score, to further increase consistency of perfusion assessment in acute ischemic stroke.

20.
Nat Biomed Eng ; 2(9): 706, 2018 Sep.
Article in English | MEDLINE | ID: mdl-31015676

ABSTRACT

In the version of this News and Views article originally published, the author name, title and year were incorrect in ref. 14 and should have read "Yang, X. et al. Coaxial cable magnetic resonance image (MRI) coil. US patent US9678180B2 (2017)." This error has now been corrected.

SELECTION OF CITATIONS
SEARCH DETAIL
...