Health Phys ; 84(5): 616-25, 2003 May.
Article in English | MEDLINE | ID: mdl-12747481

ABSTRACT

Accurate quantification of radionuclides detected during a scanning survey relies on an appropriately determined scan efficiency calibration factor (SECF). Traditionally, instrument efficiency is determined with a stationary instrument and a fixed source geometry. However, as is often the case, the instrument is used in a scanning mode where the source to instrument geometry is dynamic during the observation interval. Procedures were developed to determine the SECF for a point source ("hot particle") and a 10 x 10 cm source passing under the centerline of a 12.7 x 7.62 cm NaI(Tl) detector. The procedures were first tested to determine the SECF from a series of static point source measurements using Monte Carlo N-Particle code. These point static efficiency values were then used to predict the SECF for scan speeds ranging from 10 cm s(-1) to 80 cm s(-1) with a simulated instrument set to collect integrated counts for 1 s. The Monte Carlo N-Particle code was then used to directly determine the SECF by simulating a scan of a point source and 10 x 10 cm area source for scan speeds ranging from 10 cm s(-1) to 80 cm s(-1). Comparison with Monte Carlo N-Particle scan simulation showed the accuracy of the SECF prediction procedures to be within +/-5% for both point and area sources. Experimental results further showed the procedures developed to predict the actual SECF for a point and 10 x 10 cm source to be accurate to within +/-10%. Besides the obvious application to determine an SECF for a given scan speed, this method can be used to determine the maximum detector or source velocity for a desired minimum detectable activity. These procedures are effective and can likely be extended to determine an instrument specific SECF for a range of source sizes, scan speeds, and instrument observation intervals.


Subject(s)
Calibration , Equipment Failure Analysis/methods , Models, Statistical , Radiometry/instrumentation , Radiometry/methods , Environmental Monitoring/instrumentation , Environmental Monitoring/methods , Equipment Failure Analysis/instrumentation , Equipment Failure Analysis/standards , Monte Carlo Method , Radiation Dosage , Radioisotopes/analysis , Radiometry/standards , Reproducibility of Results , Scintillation Counting/instrumentation , Scintillation Counting/methods , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...