Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Methods ; 15(36): 4718-4727, 2023 Sep 21.
Article in English | MEDLINE | ID: mdl-37681579

ABSTRACT

Microplastics (MPs) are a size-based category of plastic pollutants between 1 µm to 5 mm in particle size that are ubiquitous in land and water resources due to anthropogenic activity. Current methodologies for MPs identification and characterization require laboratory instruments and specialized training. In the present study, a miniaturized microfluidic triboelectric sensor (M-TES) is proposed for the rapid detection of MPs from water samples. The viability and versatility of this device is illustrated for in situ measurement of the size and concentration of polystyrene (PS) micro-particles in water. The M-TES sensor relies on inducing and measuring electrical charges generated by microplastic flow within water droplets passing through a microfluidic channel. The experimental samples encompass pure polystyrene (PS) microparticles ranging from 500 nm to 10 µm, as well as actual samples collected from a coffee machine. The results reveal that the sensor's response exhibits a linear correlation with the increase in both microplastic size and concentration. The proposed sensing system could distinguish between microplastics of different sizes and concentrations. The results demonstrate the applicability of the M-TES in the field of sensors for environmental monitoring.

2.
Front Public Health ; 9: 594953, 2021.
Article in English | MEDLINE | ID: mdl-33968872

ABSTRACT

Prospective Memory (PM) is a cognitive function affected by aging. PM is the memory of future intentions and is significantly involved in everyday life, especially among older adults. Nevertheless, there are a few studies focused on PM training among healthy older adults and these studies did not report the optimal duration of training regarding improving PM performance among older adults. The present study aimed to determine the effective duration for training PM performance among healthy older adults. The current study was a randomized, controlled, single-blind, within-participants crossover trial including a training program with a duration of 12 h. The sample of 25 older adults aged 55 to 74 years recruited from the active members of the University of the Third Age (U3A), Kuala Lumpur/Selangor, their family members, and friends. The study design ensured some participants would receive the training after baseline while others would wait for 6 weeks after the baseline before receiving the training. All participants were evaluated five times: at baseline, 6, 12, 16, and at 24 weeks post-baseline. Moreover, the training program ensured all participants were assessed after each training session. The minimum number of hours to achieve training effects for this multi-component training program was eight. Results supported the efficacy of the training program in improving PM performance among healthy older adults. Also, the optimal duration for the multicomponent training program on PM performance among healthy older adults was obtained. This trial is registered at isrctn.com (#ISRCTN57600070).


Subject(s)
Memory, Episodic , Aged , Aging , Cognition , Humans , Learning , Middle Aged , Single-Blind Method
3.
Anal Biochem ; 603: 113777, 2020 08 15.
Article in English | MEDLINE | ID: mdl-32445635

ABSTRACT

A cheap/rapid technique for the fabrication of µPADs is presented for point of care analysis. Hydrophobic channels were formed across the width of the paper by spraying hot pure wax. This biocompatible novel process yielded uniform 300 ± 5 µm hydrophilic microchannels on paper, without the use of the cleanroom, UV lamp, or organic solvents and was completed in a single step without the need for a hotplate. Hot wax is properly impregnated across paper thickness by spraying under optimized temperature and pressure. Our method is advantageous in the cost and ease of fabrication, process time (<1 min), the feasibility of mass-fabrication, readout, environmental considerations and multiplexing due to the embossed structure of remnant wax. The performance of the resulting µPAD was assessed on a multiplexed Uric acid and Nitride assay, bearing 95% of confidence level in the readout against standardized tests. A novel RGB processing app was developed for smart-phones to quantify colorimetric read-outs through a heuristic normalization equation that converts RGB to integer systems. This combinatorial sensor demonstrates a good linear range (up to 800 µM for Uric acid and 1250 µM for Nitride), low detection limit (100 µM for uric acid and 156 µM for nitride).


Subject(s)
Biomarkers/analysis , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Waxes/chemistry , Colorimetry , Equipment Design , Paper , Smartphone
4.
RSC Adv ; 8(48): 27091-27100, 2018 Jul 30.
Article in English | MEDLINE | ID: mdl-35540017

ABSTRACT

A smartphone-based microfluidic platform was developed for point-of-care (POC) detection using surface plasmon resonance (SPR) of gold nanoparticles (GNPs). The simultaneous colorimetric detection of trace arsenic and mercury ions (As3+ and Hg2+) was performed using a new image processing application (app). To achieve this goal, a microfluidic kit was fabricated using a polydimethylsiloxane (PDMS) substrate with the configuration of two separated sensing regions for the quantitative measurement of the color changes in GNPs to blue/gray. To fabricate the microfluidic kit, a Plexiglas mold was cut using a laser based on the model obtained from AutoCAD and Comsol outputs. The colorimetric signals originated from the formation of nanoparticle aggregates through the interaction of GNPs with dithiothreitol - 10,12-pentacosadiynoic acid (DTT-PCDA) and lysine (Lys) in the presence of As3+ and Hg2+ ions. This assembly exhibited the advantages of simplicity, low cost, and high portability along with a low volume of reagents and multiplex detection. Heavy Metals Detector (HMD), as a new app for the RGB reader, was programmed for an Android smartphone to quantify colorimetric analyses. Compared with traditional image processing, this app provided significant improvements in sensitivity, time of analysis, and simplicity because the color intensity is measured through a new normalization equation by converting RGB to an Integer system. As a simple, real-time, and portable analytical kit, the fabricated sensor could detect low concentrations of As3+ (710 to 1278 µg L-1) and Hg2+ (10.77 to 53.86 µg L-1) ions in water samples at ambient conditions.

5.
Appl Bionics Biomech ; 2016: 8985690, 2016.
Article in English | MEDLINE | ID: mdl-27843284

ABSTRACT

The insole shape and the resulting plantar stress distribution have a pivotal impact on overall health. In this paper, by Finite Element Method, maximum stress value and stress distribution of plantar were studied for different insoles designs, which are the flat surface and the custom-molded (conformal) surface. Moreover, insole thickness, heel's height, and different materials were used to minimize the maximum stress and achieve the most uniform stress distribution. The foot shape and its details used in this paper were imported from online CT-Scan images. Results show that the custom-molded insole reduced maximum stress 40% more than the flat surface insole. Upon increase of thickness in both insole types, stress distribution becomes more uniform and maximum stress value decreases up to 10%; however, increase of thickness becomes ineffective above a threshold of 1 cm. By increasing heel height (degree of insole), maximum stress moves from heel to toes and becomes more uniform. Therefore, this scenario is very helpful for control of stress in 0.2° to 0.4° degrees for custom-molded insole and over 1° for flat insole. By changing the material of the insole, the value of maximum stress remains nearly constant. The custom-molded (conformal) insole which has 0.5 to 1 cm thickness and 0.2° to 0.4° degrees is found to be the most compatible form for foot.

SELECTION OF CITATIONS
SEARCH DETAIL
...