Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Publication year range
1.
Catheter Cardiovasc Interv ; 101(4): 764-772, 2023 03.
Article in English | MEDLINE | ID: mdl-36786488

ABSTRACT

OBJECTIVES: This study aimed to determine whether drug-coated balloon (DCB) angioplasty following intraplaque wiring and the use of modified balloons is safe and effective in the percutaneous treatment of coronary chronic total occlusions (CTOs). BACKGROUND: DCB is an alternative therapeutic option without the limitations of permanent vascular implants. However, its efficacy in CTOs has yet to be confirmed. The combination of modified balloons and DCB can be effectively applied when the intraplaque passage of the guidewire is achieved in CTOs. METHODS: Data from 124 consecutive CTO lesions (105 patients) treated at our hospital between February 2016 and December 2020 were screened for inclusion and retrospectively analyzed. Among the 118 lesions successfully recanalized, intraplaque wiring was achieved in 108, and 85 were treated by the DCB-only approach following cutting/scoring balloon dilatation. RESULTS: Follow-up data were available for 82 lesions (71 patients). The median occlusion length was 18.5 mm, and the J-CTO score was 1.7 ± 0.9. No in-hospital major adverse cardiac events occurred, including abrupt vessel closure. During the median 29-month follow-up period, target lesion revascularization was performed for 10 lesions. Follow-up coronary angiography (8.7 ± 3.9 months after the index procedure) was performed for 64 lesions, demonstrating late lumen loss of -0.15 mm (interquartile range -0.4 to 0.23 mm), binary restenosis (diameter stenosis ≥50%) in 12 lesions (18.8%), and late lumen enlargement in 37 (57.8%). CONCLUSION: The DCB-only approach following the use of modified balloons is a promising strategy for coronary CTOs when intraplaque wiring is achieved.


Subject(s)
Coronary Occlusion , Coronary Restenosis , Percutaneous Coronary Intervention , Humans , Coronary Occlusion/therapy , Coronary Vessels , Retrospective Studies , Percutaneous Coronary Intervention/adverse effects , Treatment Outcome , Coronary Angiography , Coated Materials, Biocompatible , Coronary Restenosis/etiology
2.
Gen Thorac Cardiovasc Surg ; 71(6): 331-338, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36255653

ABSTRACT

OBJECTIVE: Total arch replacement is commonly used for acute aortic dissection type A at some facilities, especially since open stent grafting became commercially available in Japan. Left subclavian artery (LSCA) reconstruction involves deep view manipulation, is difficult to expose and anastomose, and involves the risk of complications and surrounding vascular injury. METHODS: We evaluated 137 patients (mean age 73.8 ± 15.6 years) who underwent total arch replacement for acute aortic dissection type A, at our hospital between September 2014 and March 2022, and divided them into two groups: 70 patients for total arch replacement with fenestrated open stent technique (FeneOS), and 67 for conventional total arch replacement with the reconstruction of three-branch cerebral vessels. We performed FeneOS by deploying the graft from the entry of the left subclavian artery into the descending aorta and fenestrating the LSCA side of the stenting portion. The four-branched artificial vessel was then anastomosed between the left common carotid artery and LSCA. RESULTS: The surgical results of FeneOS were satisfactory and enabled significant reductions in operative time, selective cerebral perfusion time, cardiopulmonary bypass time, and lower body circulatory arrest time. Long-term observation (mean follow-up = 5.5 years) showed no left recurrent laryngeal nerve palsy or postoperative problems with left subclavian artery blood flow. CONCLUSIONS: FeneOS can minimize LSCA exposure because there is no need for LSCA reconstruction, reducing operation time and avoiding the risk of left recurrent laryngeal nerve injury and bleeding problems associated with LSCA exposure and anastomosis during left subclavian artery exposure.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Humans , Middle Aged , Aged , Aged, 80 and over , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Treatment Outcome , Stents , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Aorta, Thoracic/surgery , Blood Vessel Prosthesis
3.
J Cardiothorac Surg ; 17(1): 262, 2022 Oct 08.
Article in English | MEDLINE | ID: mdl-36209105

ABSTRACT

BACKGROUND: Open repair is the most promising curative treatment option for patients with chronic type B aortic dissection. However, based on our experience, following the accidental detection of intra-pleural adhesions during open surgery for chronic type B aortic dissection, complete replacement of the diseased aorta cannot be accomplished. To overcome this problem, we switched the procedure to create a distal landing zone for subsequent endovascular repair by replacing the distal aorta with a vascular graft. CASE PRESENTATION: We report two cases in which open repair was attempted; however, the proximal descending thoracic aorta could not be exposed due to the presence of severe adhesion in the pleural cavity. In these patients, we accessed the lower descending thoracic aorta or thoracoabdominal aorta and created a distal landing zone for subsequent endovascular repair by replacing the aorta with a vascular graft. Thereafter, endovascular repair was performed with good outcomes. CONCLUSIONS: Replacement of the distal aorta, which is typically easy to access despite the presence of intra-pleural adhesions, with a vascular graft serves as a reliable distal landing zone for subsequent endovascular repair. This method may be a viable option for the management of severe adhesions accidentally detected in the pleural cavity during open repair for chronic type B aortic dissection.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Dissection/diagnosis , Aortic Dissection/surgery , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/surgery , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Humans , Retrospective Studies , Stents , Treatment Outcome
4.
Kyobu Geka ; 73(9): 695-699, 2020 Sep.
Article in Japanese | MEDLINE | ID: mdl-32879275

ABSTRACT

In recent years, re-rupture due to endoleaks after thoracic endovascular aortic repair (TEVAR) for ruptured thoracic aortic aneurysms has become a problem. Hemoptysis has been reported in patients after pneumocentesis. We report a patient who developed delayed hemoptysis not related to endoleak after TEVAR. An 80-year-old male underwent emergent TEVAR due to a ruptured thoracic aortic aneurysm accompanying sudden hemoptysis. Eleven days after the operation, recurrent hemoptysis was noted, but contrast-enhanced computed tomography (CT) revealed no endoleak or re-rupture. Bronchoscopy demonstrated hemorrhage from the left upper lobe. As hemostasis was difficult by conservative treatment, left upper lobectomy was performed. The aortic rupture hole exhibited thrombus, and there was no hemorrhage. On histopathological examination of the resected lung, formation accompanied by severe intra-alveolar fibrosis and cholesterin clefts, and marked foreign body reactions in the interstitium and small blood vessels of the lung were observed. Cholesterol embolism is associated with not only organ ischemia due to microembolism, but also immunological mechanisms. Thus, cholesterol embolism due to aorta-derived cholesterin may have led to the delayed pulmonary hemorrhage. Differentiation from re-rupture due to endoleaks is important.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Rupture/surgery , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aged, 80 and over , Aortography , Hemoptysis , Humans , Male , Retrospective Studies , Stents , Time Factors , Treatment Outcome
6.
Gen Thorac Cardiovasc Surg ; 66(3): 145-149, 2018 03.
Article in English | MEDLINE | ID: mdl-29124558

ABSTRACT

OBJECTIVES: The Blalock-Taussig shunt (BTS) operation is a cornerstone as initial palliative surgery for congenital heart disease with severely reduced pulmonary blood flow (PBF). The ideal PBF provided by BTS is crucial for an uneventful postoperative course, since excess PBF results in acute distress of the systemic circulation and insufficient PBF requires another BTS surgery. Therefore, the goal of this study was to develop a simple device to control the shunt graft flow percutaneously using a constrictor balloon connected to a subcutaneous port. METHODS: The device consists of a cylindrical balloon and an anti-bending structure extension connected to the balloon center. A PTFE vascular graft wrapped by the device was connected to a simulated closed circuit to measure the relationship between pressure and blood flow while changing the inner volume of the balloon. In a beagle model of replacement of the right carotid artery, blood flow velocity was measured in the carotid artery after saline injection into the balloon. The blood flow velocity before and after balloon inflation was compared immediately after implantation of the device and at 3 months after implantation. RESULTS: The device provided good flow control by inflating and deflating the balloon ex vivo and in vivo for up to 3 months in a canine model with a small graft wrapped with the device. CONCLUSIONS: The simple device developed in this study may enable regulation of PBF through a small vascular graft and help to prevent severe morbidity and mortality in the clinical setting of BTS.


Subject(s)
Blalock-Taussig Procedure , Blood Vessel Prosthesis Implantation , Cardiac Surgical Procedures , Heart Defects, Congenital/surgery , Pulmonary Artery/surgery , Pulmonary Circulation/physiology , Animals , Carotid Artery, Common/surgery , Dogs , Heart Defects, Congenital/physiopathology , Hemodynamics , Male , Models, Animal , Palliative Care , Vascular Surgical Procedures
7.
Kyobu Geka ; 70(10): 811-815, 2017 Sep.
Article in Japanese | MEDLINE | ID: mdl-28894052

ABSTRACT

Quadricuspid aortic valve is a rare congenital disease. We experienced 3 surgical cases of quadricuspid aortic valve. Patient 1 was a 72-year-old man who was noted to have a quadricuspid aortic valve associated with aortic regurgitation and an ascending aortic aneurysm(51 mm in diameter). He underwent replacement of the aortic valve and the ascending aorta. Patient 2 was a 71-year-old man with severe aortic stenosis, regurgitation, and coronary triple vessel disease. He underwent aortic valve replacement and coronary artery bypass grafting. Preoperative echocardiography revealed no abnormalities in the number of valve leaflets, but quadricuspid aortic valve was identified during surgery. Patient 3 was a 79-year-old man with severe aortic regurgitation, who underwent aortic valve replacement. In all patients, the 4 valve cusps were approximately of the same size. Multi-detector computed tomography is useful for evaluation of valve morphology. Indication of prophylactic ascending aorta replacement in patients with aortic dilatation requires further study.


Subject(s)
Aortic Valve Insufficiency/surgery , Aortic Valve/surgery , Aged , Aortic Valve/diagnostic imaging , Aortic Valve Insufficiency/diagnostic imaging , Cardiac Catheters , Heart Valve Prosthesis Implantation , Humans , Male
8.
Kyobu Geka ; 70(9): 791-793, 2017 Aug.
Article in Japanese | MEDLINE | ID: mdl-28790248

ABSTRACT

A 77-year-old man, who had been under medical treatment for myasthenia gravis without thymoma, was diagnosed with aortic arch aneurysm. He underwent total aortic arch replacement and total resection of the thymus through median sternotomy. His symptoms relating to myasthenia gravis dramatically disappeared after the surgery. The serum anti-acetyl chorine receptor antibody decreased from 2.7 to 0.7 nmol/l (N<0.2) with the reduction of oral predonisolone from 12.5 to 5 mg/day at 4 years after the surgery. The concomitant operations significantly improved his quality of life.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Myasthenia Gravis/surgery , Aged , Aortic Aneurysm, Thoracic/diagnostic imaging , Humans , Male , Myasthenia Gravis/diagnostic imaging , Tomography, X-Ray Computed
9.
Kyobu Geka ; 65(10): 872-5, 2012 Sep.
Article in Japanese | MEDLINE | ID: mdl-22940657

ABSTRACT

We report a successful arterial switch operation for complete transposition of great arteries with atrial and visceral situs inversus totalis and mirror image dextrocardia in a 12-day-old infant girl. The aorta was located left side-by-side to the pulmonary trunk with a single coronary artery (mirror image of 1RLCx). After French maneuver, the posterior circumference of the neo-aorta was reconstructed. Then the coronary button was transplanted into the neo-aorta with a trap door technique carefully avoiding any twist and over-stretch. The neo-pulmonary trunk was reconstructed with an autologous pericardial patch and sutured to the longitudinal incision made into the left central pulmonary artery. The baby was discharged from hospital and has been doing well without any morbidity relating myocardial ischemia.


Subject(s)
Dextrocardia/complications , Situs Inversus/complications , Transposition of Great Vessels/surgery , Cardiovascular Surgical Procedures/methods , Female , Humans , Infant, Newborn
SELECTION OF CITATIONS
SEARCH DETAIL
...