Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
AJNR Am J Neuroradiol ; 44(2): 165-170, 2023 02.
Article in English | MEDLINE | ID: mdl-36635056

ABSTRACT

BACKGROUND: The Woven EndoBridge device was originally approved to treat intracranial wide-neck saccular bifurcation aneurysms. Recent studies have suggested its use for the treatment of sidewall intracranial aneurysms with variable success. PURPOSE: Our aim was to evaluate the safety and efficacy of the Woven EndoBridge device for sidewall aneurysms using a meta-analysis of the literature. DATA SOURCES: We performed a systematic review of all studies including patients treated with the Woven EndoBridge device for sidewall aneurysms from inception until May 2022 on Scopus, EMBASE, MEDLINE, the Web of Science, and the Cochrane Central Register of Controlled Trials. STUDY SELECTION: Ten studies were selected, and 285 patients with 288 sidewall aneurysms were included. DATA ANALYSIS: A random-effects meta-analysis of proportions using a generalized linear mixed model was performed as appropriate. Statistical heterogeneity across studies was assessed with I2 statistics. DATA SYNTHESIS: The adequate occlusion rate at last follow-up was 89% (95% CI, 81%-94%; I2, = 0%), the composite safety outcome was 8% (95% CI, 3%-17%; I2 = 34%), and the mortality rate was 2% (95% CI, 1%-7%; I2 = 0%). Aneurysm width (OR = 0.5; P = .03) was the only significant predictor of complete occlusion. LIMITATIONS: Given the level of evidence, our results should be interpreted cautiously until confirmation from larger prospective studies is obtained. CONCLUSIONS: The initial evidence evaluating the use of the Woven EndoBridge device for the treatment of wide-neck sidewall intracranial aneurysms has demonstrated high rates of adequate occlusion with low procedural complications. Our findings favor the consideration of the Woven EndoBridge device as an option for the treatment of sidewall aneurysms.


Subject(s)
Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/therapy , Treatment Outcome , Prospective Studies , Embolization, Therapeutic/methods , Endovascular Procedures/methods , Retrospective Studies
2.
J Clin Neurosci ; 58: 20-24, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30454690

ABSTRACT

BACKGROUND AND PURPOSE: Flow-diversion therapy (FDT) for large and complex intracranial aneurysms is effective and considered superior to primary coil embolization. Data evaluating common treatment with both FDT and coiling continues to emerge, but information on outcomes remains scarce. This study aims to examine further the efficiency and outcomes correlated with joint FDT using pipeline embolization device (PED) and coiling compared to PED-alone in treating intracranial aneurysms. MATERIALS AND METHODS: Comparative review and analysis of aneurysm treatment with PED in 416 subjects were conducted. Joint modality, PED, and coiling were compared to PED-alone for aneurysm occlusion, recurrence, retreatment, thromboembolic or hemorrhagic events, and functional outcome using the modified Rankin Scale. Data on patient demographics, aneurysm characteristics, clinical and angiographic follow up, were also collected. Both univariate analysis and multivariate logistic regression modeling using mixed-effects were performed. RESULTS: Total of 437 aneurysms were treated using PED of which 74 were managed with both PED and coiling. Average patient-age was 56 years, the majority were men (85%), an average aneurysm size was 9 mm, and the majority were saccular aneurysms (84%). Larger aneurysm size was associated with a poor outcome in patients with unruptured aneurysms (OR = 1.06). Adjusted regression analyses revealed no differences between treatment groups in thromboembolic or hemorrhagic events, aneurysm occlusion rate, residual flow on follow up angiography, or functional outcome. CONCLUSIONS: Treatment of intracranial aneurysms with joint PED and coiling was safe with no increase in complications when compared to PED alone. Aneurysm occlusion rates and functional outcome with PED and coiling stays comparable to treatment with PED-alone.


Subject(s)
Embolization, Therapeutic/methods , Endovascular Procedures/methods , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/therapy , Self Expandable Metallic Stents , Adult , Aged , Angiography, Digital Subtraction/instrumentation , Angiography, Digital Subtraction/methods , Blood Vessel Prosthesis , Embolization, Therapeutic/instrumentation , Endovascular Procedures/instrumentation , Female , Follow-Up Studies , Humans , Longitudinal Studies , Male , Middle Aged , Platelet Aggregation Inhibitors/administration & dosage , Retreatment/instrumentation , Retreatment/methods , Retrospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...