1.
Radiat Prot Dosimetry ; 110(1-4): 333-6, 2004.
Article in English | MEDLINE | ID: mdl-15353669

ABSTRACT

Imaging plate (IP) radiation detectors are widely used in industrial radiography, medical imagery and autoradiography. When an IP is exposed to ionising radiation, some of the energy is absorbed to form a latent image. The energy stored, which is proportional to the dose received, can be liberated by a selective optical stimulation and collected to reconstitute the distribution of the ionising radiation on the IP. In this work, IPs for use in fast-neutron measurements are characterised. The response of our IP dosemeters in conjunction with their reading system was found to be linear in dose between 75 microSv and 10 mSv. This performance is compared with those of dosemeters based on the plastic track detectors PN3 and CR-39.


Subject(s)
Fast Neutrons , Film Dosimetry/instrumentation , Linear Energy Transfer , Occupational Exposure/analysis , Radiation Protection/instrumentation , Radioisotopes/analysis , Body Burden , Environmental Exposure/analysis , Equipment Design , Equipment Failure Analysis/methods , Film Dosimetry/methods , Radiation Dosage , Radiation Protection/methods , Relative Biological Effectiveness , Reproducibility of Results , Scattering, Radiation , Sensitivity and Specificity
2.
Radiat Prot Dosimetry ; 110(1-4): 701-4, 2004.
Article in English | MEDLINE | ID: mdl-15353734

ABSTRACT

Measurement of the personal dose equivalent rates for neutrons is a difficult task because available dosemeters do not provide the required energy response and sensitivity. Furthermore, the available wide calibration spectra recommended by the International Standard Organisation does not reproduce adequately the spectra encountered in practical situations of the nuclear industry. There is a real necessity to characterise the radiation field, in which workers can be exposed, and to calibrate personal dosemeters in order to determine the dose equivalent in these installations. For this reason, we measure the neutron spectrum with our Bonner sphere system and we fold this spectrum with energy-dependent fluence-to-dose conversion coefficients to obtain the reference dose equivalent rate. This reference value is then compared with the personal dosemeter reading to determine a field-specific correction factor. In this paper, we present the values of this field-specific correction factor for etched track and albedo thermoluminescence dosemeters at three measurement locations inside the containment building of the Vandellòs II nuclear power plant. We have found that assigning to each personal dosemeter the mean value of the field-specific correction factors of the three measurement locations, allows the evaluation of neutron personal dose equivalent rate with a relative uncertainty of approximately 25 and 15% for the PADC and albedo dosemeters, respectively.


Subject(s)
Neutrons , Occupational Exposure/analysis , Power Plants , Radiation Protection/instrumentation , Radioactive Hazard Release , Risk Assessment/methods , Thermoluminescent Dosimetry/instrumentation , Body Burden , Equipment Failure Analysis/instrumentation , Humans , Quality Assurance, Health Care/methods , Radiation Dosage , Radiation Protection/methods , Relative Biological Effectiveness , Reproducibility of Results , Risk Factors , Safety Management/methods , Sensitivity and Specificity , Thermoluminescent Dosimetry/methods