Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Cardiovasc Magn Reson ; 24(1): 3, 2022 01 03.
Article in English | MEDLINE | ID: mdl-34980165

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is a progressive condition, which is characterized by inflammation/fibrosis of left atrial (LA) wall, an increase in the LA size/volumes, and decrease in LA function. We sought to investigate the relationship of anatomical and functional parameters obtained by cardiovascular magnetic resonance (CMR), with AF recurrence in paroxysmal AF (pAF) patients after catheter ablation. METHODS: We studied 80 consecutive pAF patients referred for ablation, between January 2014 and December 2019, who underwent pre- and post-ablation CMR while in sinus rhythm. LA volumes were measured using the area-length method and included maximum, minimum, and pre-atrial-contraction volumes. CMR-derived LA reservoir strain (ℇR), conduit strain (ℇCD), and contractile strain (ℇCT) were measured by computer assisted manual planimetry. We used a multivariate logistical regression to estimate the independent predictors of AF recurrence after ablation. RESULTS: Mean age was 58.6 ± 9.4 years, 75% men, mean CHA2DS2-VASc score was 1.7, 36% had prior cardioversion and 51% were taking antiarrhythmic drugs. Patients were followed for a median of 4 years (Q1-Q3 = 2.5-6.2 years). Of the 80 patients, 21 (26.3%) patients had AF recurrence after ablation. There were no significant differences between AF recurrence vs. no recurrence groups in age, gender, CHA2DS2-VASc score, or baseline comorbidities. At baseline, patients with AF recurrence compared to without recurrence had lower LV end systolic volume index (32 ± 7 vs 37 ± 11 mL/m2; p = 0.045) and lower ℇCT (7.1 ± 4.6 vs 9.1 ± 3.7; p = 0.05). Post-ablation, patients with AF recurrence had higher LA minimum volume (68 ± 32 vs 55 ± 23; p = 0.05), right atrial volume index (62 ± 20 vs 52 ± 19 mL/m2; p = 0.04) and lower LA active ejection fraction (24 ± 8 vs 29 ± 11; p = 0.05), LA total ejection fraction (39 ± 14 vs 46 ± 12; p = 0.02), LA expansion index (73.6 ± 37.5 vs 94.7 ± 37.1; p = 0.03) and ℇCT (6.2 ± 2.9 vs 7.3 ± 1.7; p = 0.04). Adjusting for clinical variables in the multivariate logistic regression model, post-ablation minimum LA volume (OR 1.09; CI 1.02-1.16), LA expansion index (OR 0.98; CI 0.96-0.99), and baseline ℇR (OR 0.92; CI 0.85-0.99) were independently associated with AF recurrence. CONCLUSION: Significant changes in LA volumes and strain parameters occur after AF ablation. CMR derived baseline ℇR, post-ablation minimum LAV, and expansion index are independently associated with AF recurrence.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Aged , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Female , Heart Atria/diagnostic imaging , Heart Atria/surgery , Humans , Magnetic Resonance Spectroscopy , Male , Middle Aged , Predictive Value of Tests , Recurrence , Treatment Outcome
2.
J Interv Card Electrophysiol ; 52(3): 335-341, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29907894

ABSTRACT

PURPOSE: Bifascicular block and prolonged PR interval on the electrocardiogram (ECG) have been associated with complete heart block and sudden cardiac death. We sought to determine if cardiac implantable electronic devices (CIED) improve survival in these patients. METHODS: We assessed survival in relation to CIED status among 636 consecutive patients with bifascicular block and prolonged PR interval on the ECG. In survival analyses, CIED was considered as a time-varying covariate. RESULTS: Average age was 76 ± 9 years, and 99% of the patients were men. A total of 167 (26%) underwent CIED (127 pacemaker only) implantation at baseline (n = 23) or during follow-up (n = 144). During 5.4 ± 3.8 years of follow-up, 83 (13%) patients developed complete or high-degree atrioventricular block and 375 (59%) died. Patients with a CIED had a longer survival compared to those without a CIED in the traditional, static analysis (log-rank p < 0.0001) but not when CIED was considered as a time-varying covariate (log-rank p = 0.76). In the multivariable model, patients with a CIED had a 34% lower risk of death (hazard ratio 0.66, 95% confidence interval 0.52-0.83; p = 0.001) than those without CIED in the traditional analysis but not in the time-varying covariate analysis (hazard ratio 1.05, 95% confidence interval 0.79-1.38; p = 0.76). Results did not change in the subgroup with a pacemaker only. CONCLUSIONS: Bifascicular block and prolonged PR interval on ECG are associated with a high incidence of complete atrioventricular block and mortality. However, CIED implantation does not have a significant influence on survival when time-varying nature of CIED implantation is considered.


Subject(s)
Atrioventricular Block/therapy , Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy/mortality , Death, Sudden, Cardiac , Defibrillators, Implantable , Aged , Aged, 80 and over , Atrioventricular Block/diagnostic imaging , Atrioventricular Block/mortality , Atrioventricular Block/physiopathology , Bundle-Branch Block/diagnostic imaging , Bundle-Branch Block/mortality , Bundle-Branch Block/physiopathology , Cardiac Resynchronization Therapy/methods , Cohort Studies , Electrocardiography/methods , Female , Humans , Kaplan-Meier Estimate , Male , Prognosis , Proportional Hazards Models , Retrospective Studies , Risk Assessment , Severity of Illness Index , Statistics, Nonparametric , Survival Analysis , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...