Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 54
Filter
1.
Open Forum Infect Dis ; 11(3): ofae048, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38434615

ABSTRACT

Background: Bacillus cereus is a ubiquitous gram-positive rod-shaped bacterium that can cause sepsis and neuroinvasive disease in patients with acute leukemia or neutropenia. Methods: A single-center retrospective review was conducted to evaluate patients with acute leukemia, positive blood or cerebrospinal fluid test results for B cereus, and abnormal neuroradiographic findings between January 2018 and October 2022. Infection control practices were observed, environmental samples obtained, a dietary case-control study completed, and whole genome sequencing performed on environmental and clinical Bacillus isolates. Results: Five patients with B cereus neuroinvasive disease were identified. All patients had acute myeloid leukemia (AML), were receiving induction chemotherapy, and were neutropenic. Neurologic involvement included subarachnoid or intraparenchymal hemorrhage or brain abscess. All patients were treated with ciprofloxacin and survived with limited or no neurologic sequelae. B cereus was identified in 7 of 61 environmental samples and 1 of 19 dietary protein samples-these were unrelated to clinical isolates via sequencing. No point source was identified. Ciprofloxacin was added to the empiric antimicrobial regimen for patients with AML and prolonged or recurrent neutropenic fevers; no new cases were identified in the ensuing year. Conclusions: B cereus is ubiquitous in the hospital environment, at times leading to clusters with unrelated isolates. Fastidious infection control practices addressing a range of possible exposures are warranted, but their efficacy is unknown and they may not be sufficient to prevent all infections. Thus, including B cereus coverage in empiric regimens for patients with AML and persistent neutropenic fever may limit the morbidity of this pathogen.

2.
Infect Control Hosp Epidemiol ; 45(3): 292-301, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38196201

ABSTRACT

OBJECTIVE: We investigated concurrent outbreaks of Pseudomonas aeruginosa carrying blaVIM (VIM-CRPA) and Enterobacterales carrying blaKPC (KPC-CRE) at a long-term acute-care hospital (LTACH A). METHODS: We defined an incident case as the first detection of blaKPC or blaVIM from a patient's clinical cultures or colonization screening test. We reviewed medical records and performed infection control assessments, colonization screening, environmental sampling, and molecular characterization of carbapenemase-producing organisms from clinical and environmental sources by pulsed-field gel electrophoresis (PFGE) and whole-genome sequencing. RESULTS: From July 2017 to December 2018, 76 incident cases were identified from 69 case patients: 51 had blaKPC, 11 had blaVIM, and 7 had blaVIM and blaKPC. Also, blaKPC were identified from 7 Enterobacterales, and all blaVIM were P. aeruginosa. We observed gaps in hand hygiene, and we recovered KPC-CRE and VIM-CRPA from drains and toilets. We identified 4 KPC alleles and 2 VIM alleles; 2 KPC alleles were located on plasmids that were identified across multiple Enterobacterales and in both clinical and environmental isolates. CONCLUSIONS: Our response to a single patient colonized with VIM-CRPA and KPC-CRE identified concurrent CPO outbreaks at LTACH A. Epidemiologic and genomic investigations indicated that the observed diversity was due to a combination of multiple introductions of VIM-CRPA and KPC-CRE and to the transfer of carbapenemase genes across different bacteria species and strains. Improved infection control, including interventions that minimized potential spread from wastewater premise plumbing, stopped transmission.


Subject(s)
Bacterial Proteins , beta-Lactamases , Humans , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/therapeutic use , Bacterial Proteins/genetics , beta-Lactamases/genetics , Hospitals , Klebsiella pneumoniae , Microbial Sensitivity Tests , Plasmids
3.
Infect Control Hosp Epidemiol ; 44(12): 2052-2055, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37929567

ABSTRACT

In this summary of US Centers for Disease Control and Prevention (CDC) consultations with state and local health departments concerning their bronchoscope-associated investigations from 2014 through 2022, bronchoscope reprocessing gaps and exposure to nonsterile water sources appeared to be the major routes of transmission of infectious pathogens, which were primarily water-associated bacteria.


Subject(s)
Bronchoscopes , Communicable Diseases , United States , Humans , Centers for Disease Control and Prevention, U.S. , Referral and Consultation , Water
4.
Open Forum Infect Dis ; 10(5): ofad194, 2023 May.
Article in English | MEDLINE | ID: mdl-37180588

ABSTRACT

Background: Contaminated healthcare facility wastewater plumbing is recognized as a source of carbapenemase-producing organism transmission. In August 2019, the Tennessee Department of Health (TDH) identified a patient colonized with Verona integron-encoded metallo-beta-lactamase-producing carbapenem-resistant Pseudomonas aeruginosa (VIM-CRPA). A record review revealed that 33% (4 of 12) of all reported patients in Tennessee with VIM had history of prior admission to acute care hospital (ACH) A intensive care unit (ICU) Room X, prompting further investigation. Methods: A case was defined as polymerase chain reaction detection of blaVIM in a patient with prior admission to ACH A from November 2017 to November 2020. The TDH performed point prevalence surveys, discharge screening, onsite observations, and environmental testing at ACH A. The VIM-CRPA isolates underwent whole-genome sequencing (WGS). Results: In a screening of 44% (n = 11) of 25 patients admitted to Room X between January and June 2020, we identified 36% (n = 4) colonized with VIM-CRPA, resulting in 8 cases associated with Room X from March 2018 to June 2020. No additional cases were identified in 2 point-prevalence surveys of the ACH A ICU. Samples from the bathroom and handwashing sink drains in Room X grew VIM-CRPA; all available case and environmental isolates were found to be ST253 harboring blaVIM-1 and to be closely related by WGS. Transmission ended after implementation of intensive water management and infection control interventions. Conclusions: A single ICU room's contaminated drains were associated with 8 VIM-CRPA cases over a 2-year period. This outbreak highlights the need to include wastewater plumbing in hospital water management plans to mitigate the risk of transmission of antibiotic-resistant organisms to patients.

5.
Am J Infect Control ; 51(4): 454-460, 2023 04.
Article in English | MEDLINE | ID: mdl-35732255

ABSTRACT

BACKGROUND: We describe the investigation of a nosocomial outbreak of rapidly growing mycobacteria (RGM) infections and the results of mitigation efforts after 8 years. METHODS: A cluster of RGM cases in a Kentucky hospital in 2013 prompted an investigation into RGM surgical site infections following joint replacement surgery. A case-control study was conducted to identify risk factors. RESULTS: Eight cases were identified, 5 caused by M. wolinskyi and 3 by M. goodii. The case-control study showed the presence of a particular nurse in the operating room was significantly associated with infection. Environmental sampling at the nurse's home identified an outdoor hot tub as the likely source of M. wolinskyi, confirmed by pulsed-field gel electrophoresis and whole genome sequencing. The hot tub reservoir was eliminated, and hospital policies were revised to correct infection control lapses. No new cases of RGM infections have been identified as of 2021. DISCUSSION: Breaches in infection control practices at multiple levels may have led to a chain of infection from a nurse's hot tub to surgical sites via indirect person-to-person transmission from a colonized health care worker (HCW). CONCLUSIONS: The multifactorial nature of the outbreak's cause highlights the importance of overlapping or redundant layers of protection preventing patient harm. Future investigations of RGM outbreaks should consider the potential role of colonized HCWs as a transmission vector.


Subject(s)
Arthroplasty, Replacement , Mycobacterium Infections, Nontuberculous , Humans , Mycobacterium Infections, Nontuberculous/epidemiology , Mycobacterium Infections, Nontuberculous/microbiology , Nontuberculous Mycobacteria , Case-Control Studies , Follow-Up Studies , Kentucky/epidemiology , Hospitals , Disease Outbreaks
6.
Am J Infect Control ; 51(6): 638-643, 2023 06.
Article in English | MEDLINE | ID: mdl-35970421

ABSTRACT

BACKGROUND: Maintenance hemodialysis (HD) patients are at increased risk of bloodstream infections (BSI). We investigated a cluster of Delftia acidovorans infections among patients undergoing HD at an outpatient unit (Facility A). METHODS: A case was defined as a Facility A HD patient with ≥1 culture positive for D acidovorans between February 1 and April 30, 2018. An investigation included review of patient records, facility policies, practice observations, and environmental cultures. RESULTS: The cluster included 2 patients with confirmed D acidovorans BSI. Both patients had recently been dialyzed at Station #2, where a wall box culture yielded D acidovorans. One patient also had a BSI due to Enterobacter asburiae, which was recovered from several other wall boxes and saline prime buckets (SPB). Observations revealed leakage of wastewater from wall boxes onto the floor, and that SPBs were not always disinfected and dried appropriately before reuse. Multiple deficiencies in hand hygiene and station disinfection were observed. No deficiencies in water treatment practices were identified, and water cultures were negative for the observed pathogens. CONCLUSIONS: The cluster of D acidovorans infections was most likely due to indirect exposures to contaminated wall boxes and possibly SPBs due to poor hand hygiene and station disinfection.


Subject(s)
Bacteremia , Gram-Negative Bacterial Infections , Sepsis , Humans , Connecticut , Bacteremia/epidemiology , Bacteremia/etiology , Renal Dialysis/adverse effects , Sepsis/etiology , Disinfection , Gram-Negative Bacterial Infections/epidemiology
7.
MMWR Morb Mortal Wkly Rep ; 71(48): 1517-1521, 2022 Dec 02.
Article in English | MEDLINE | ID: mdl-36454695

ABSTRACT

In July 2021, the Virginia Department of Health notified CDC of a cluster of eight invasive infections with Burkholderia stabilis, a bacterium in the Burkholderia cepacia complex (BCC), among hospitalized patients at hospital A. Most patients had undergone ultrasound-guided procedures during their admission. Culture of MediChoice M500812 nonsterile ultrasound gel used in hospital A revealed contamination of unopened product with B. stabilis that matched the whole genome sequencing (WGS) of B. stabilis strains found among patients. CDC and hospital A, in collaboration with partner health care facilities, state and local health departments, and the Food and Drug Administration (FDA), identified 119 B. stabilis infections in 10 U.S. states, leading to the national recall of all ultrasound gel products produced by Eco-Med Pharmaceutical (Eco-Med), the manufacturer of MediChoice M500812. Additional investigation of health care facility practices revealed frequent use of nonsterile ultrasound gel to assist with visualization in preparation for or during invasive, percutaneous procedures (e.g., intravenous catheter insertion). This practice could have allowed introduction of contaminated ultrasound gel into sterile body sites when gel and associated viable bacteria were not completely removed from skin, leading to invasive infections. This outbreak highlights the importance of appropriate use of ultrasound gel within health care settings to help prevent patient infections, including the use of only sterile, single-use ultrasound gel for ultrasonography when subsequent percutaneous procedures might be performed.


Subject(s)
Burkholderia Infections , Disease Outbreaks , Equipment Contamination , Health Facilities , Humans , Drug Contamination , Ultrasonography , United States/epidemiology , Gels , Burkholderia Infections/epidemiology , Burkholderia Infections/etiology
9.
Epidemiol Infect ; 150: e154, 2022 08 04.
Article in English | MEDLINE | ID: mdl-35923078

ABSTRACT

In March 2018, the US Food and Drug Administration (FDA), US Centers for Disease Control and Prevention, California Department of Public Health, Los Angeles County Department of Public Health and Pennsylvania Department of Health initiated an investigation of an outbreak of Burkholderia cepacia complex (Bcc) infections. Sixty infections were identified in California, New Jersey, Pennsylvania, Maine, Nevada and Ohio. The infections were linked to a no-rinse cleansing foam product (NRCFP), produced by Manufacturer A, used for skin care of patients in healthcare settings. FDA inspected Manufacturer A's production facility (manufacturing site of over-the-counter drugs and cosmetics), reviewed production records and collected product and environmental samples for analysis. FDA's inspection found poor manufacturing practices. Analysis by pulsed-field gel electrophoresis confirmed a match between NRCFP samples and clinical isolates. Manufacturer A conducted extensive recalls, FDA issued a warning letter citing the manufacturer's inadequate manufacturing practices, and federal, state and local partners issued public communications to advise patients, pharmacies, other healthcare providers and healthcare facilities to stop using the recalled NRCFP. This investigation highlighted the importance of following appropriate manufacturing practices to minimize microbial contamination of cosmetic products, especially if intended for use in healthcare settings.


Subject(s)
Burkholderia Infections , Burkholderia cepacia complex , Cross Infection , Aerosols , Burkholderia Infections/epidemiology , Cross Infection/epidemiology , Disease Outbreaks , Electrophoresis, Gel, Pulsed-Field , Humans , United States/epidemiology
10.
Pathogens ; 11(8)2022 07 23.
Article in English | MEDLINE | ID: mdl-35894048

ABSTRACT

Abstract Bacillus cereus group bacteria containing the anthrax toxin genes can cause fatal anthrax pneumonia in welders. Two welder's anthrax cases identified in 2020 were investigated to determine the source of each patient's exposure. Environmental sampling was performed at locations where each patient had recent exposure to soil and dust. Samples were tested for the anthrax toxin genes by real-time PCR, and culture was performed on positive samples to identify whether any environmental isolates matched the patient's clinical isolate. A total of 185 environmental samples were collected in investigation A for patient A and 108 samples in investigation B for patient B. All samples from investigation B were real-time PCR-negative, but 14 (8%) samples from investigation A were positive, including 10 from patient A's worksite and 4 from his work-related clothing and gear. An isolate genetically matching the one recovered from patient A was successfully cultured from a worksite soil sample. All welder's anthrax cases should be investigated to determine the source of exposure, which may be linked to their worksite. Welding and metalworking employers should consider conducting a workplace hazard assessment and implementing controls to reduce the risk of occupationally associated illnesses including welder's anthrax.

11.
Infect Control Hosp Epidemiol ; 43(10): 1333-1338, 2022 10.
Article in English | MEDLINE | ID: mdl-34612179

ABSTRACT

BACKGROUND: In 2015, an international outbreak of Mycobacterium chimaera infections among patients undergoing cardiothoracic surgeries was associated with exposure to contaminated LivaNova 3T heater-cooler devices (HCDs). From June 2017 to October 2020, the Centers for Disease Control and Prevention was notified of 18 patients with M. chimaera infections who had undergone cardiothoracic surgeries at 2 hospitals in Kansas (14 patients) and California (4 patients); 17 had exposure to 3T HCDs. Whole-genome sequencing of the clinical and environmental isolates matched the global outbreak strain identified in 2015. METHODS: Investigations were conducted at each hospital to determine the cause of ongoing infections. Investigative methods included query of microbiologic records to identify additional cases, medical chart review, observations of operating room setup, HCD use and maintenance practices, and collection of HCD and environmental samples. RESULTS: Onsite observations identified deviations in the positioning and maintenance of the 3T HCDs from the US Food and Drug Administration (FDA) recommendations and the manufacturer's updated cleaning and disinfection protocols. Additionally, most 3T HCDs had not undergone the recommended vacuum and sealing upgrades by the manufacturer to decrease the dispersal of M. chimaera-containing aerosols into the operating room, despite hospital requests to the manufacturer. CONCLUSIONS: These findings highlight the need for continued awareness of the risk of M. chimaera infections associated with 3T HCDs, even if the devices are newly manufactured. Hospitals should maintain vigilance in adhering to FDA recommendations and the manufacturer's protocols and in identifying patients with potential M. chimaera infections with exposure to these devices.


Subject(s)
Mycobacterium Infections, Nontuberculous , Mycobacterium Infections , Humans , Equipment Contamination , Kansas , Chimera , Mycobacterium Infections/epidemiology , Mycobacterium Infections/etiology , Mycobacterium avium Complex , Aerosols , Mycobacterium Infections, Nontuberculous/epidemiology , Mycobacterium Infections, Nontuberculous/etiology , Mycobacterium Infections, Nontuberculous/prevention & control
12.
MMWR Morb Mortal Wkly Rep ; 70(42): 1472-1477, 2021 Oct 22.
Article in English | MEDLINE | ID: mdl-34673748

ABSTRACT

During December 2018-February 2019, a multistate investigation identified 101 patients with vaccination-associated adverse events among an estimated 940 persons in Kentucky, Indiana, and Ohio who had received influenza; hepatitis A; pneumococcal; or tetanus toxoid, reduced diphtheria toxoid, and acellular pertussis (Tdap) vaccines at the workplace during September 11-November 28, 2018. These vaccines had been administered by staff members of a third-party health care company contracted by 24 businesses. Company A provided multiple vaccine types during workplace vaccination events across 54 locations in these adjoining states. Injection-site wound isolates from patients yielded Mycobacterium porcinum, a nontuberculous mycobacteria (NTM) species in the Mycobacterium fortuitum group; subtyping using pulsed-field gel electrophoresis of all 28 available isolates identified two closely related clusters. Site visits to company A and interviews with staff members identified inadequate hand hygiene, improper vaccine storage and handling, lack of appropriate medical record documentation, and lack of reporting to the Vaccine Adverse Event Reporting System (VAERS). Vaccination-associated adverse events can be prevented by training health care workers responsible for handling or administering vaccines in safe vaccine handling, administration, and storage practices, timely reporting of any suspected vaccination-associated adverse events to VAERS, and notifying public health authorities of any adverse event clusters.


Subject(s)
Mycobacteriaceae/isolation & purification , Skin Diseases, Bacterial/epidemiology , Soft Tissue Infections/epidemiology , Vaccination/adverse effects , Adult , Aged , Female , Humans , Indiana/epidemiology , Kentucky/epidemiology , Male , Middle Aged , Ohio/epidemiology , Skin Diseases, Bacterial/microbiology , Soft Tissue Infections/microbiology , Young Adult
13.
Clin Infect Dis ; 72(3): 414-420, 2021 02 01.
Article in English | MEDLINE | ID: mdl-32255490

ABSTRACT

BACKGROUND: Antibiotic resistance is often spread through bacterial populations via conjugative plasmids. However, plasmid transfer is not well recognized in clinical settings because of technical limitations, and health care-associated infections are usually caused by clonal transmission of a single pathogen. In 2015, multiple species of carbapenem-resistant Enterobacteriaceae (CRE), all producing a rare carbapenemase, were identified among patients in an intensive care unit. This observation suggested a large, previously unrecognized plasmid transmission chain and prompted our investigation. METHODS: Electronic medical record reviews, infection control observations, and environmental sampling completed the epidemiologic outbreak investigation. A laboratory analysis, conducted on patient and environmental isolates, included long-read whole-genome sequencing to fully elucidate plasmid DNA structures. Bioinformatics analyses were applied to infer plasmid transmission chains and results were subsequently confirmed using plasmid conjugation experiments. RESULTS: We identified 14 Verona integron-encoded metallo-ß-lactamase (VIM)-producing CRE in 12 patients, and 1 additional isolate was obtained from a patient room sink drain. Whole-genome sequencing identified the horizontal transfer of blaVIM-1, a rare carbapenem resistance mechanism in the United States, via a promiscuous incompatibility group A/C2 plasmid that spread among 5 bacterial species isolated from patients and the environment. CONCLUSIONS: This investigation represents the largest known outbreak of VIM-producing CRE in the United States to date, which comprises numerous bacterial species and strains. We present evidence of in-hospital plasmid transmission, as well as environmental contamination. Our findings demonstrate the potential for 2 types of hospital-acquired infection outbreaks: those due to clonal expansion and those due to the spread of conjugative plasmids encoding antibiotic resistance across species.


Subject(s)
Cross Infection , Integrons , Anti-Bacterial Agents/pharmacology , Bacterial Proteins/genetics , Cross Infection/epidemiology , Disease Outbreaks , Drug Resistance, Multiple, Bacterial/genetics , Humans , Microbial Sensitivity Tests , Plasmids/genetics , beta-Lactamases/genetics , beta-Lactamases/metabolism
14.
Gastrointest Endosc Clin N Am ; 30(4): 723-733, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32891228

ABSTRACT

Flexible endoscopes require cleaning, high-level disinfection, and sterilization between each patient use to reduce risk of transmitting pathogens. Public health investigations have identified concerns, including endoscope damage, mishandling, and reprocessing deficiencies, placing patients at risk for transmission of bacterial, viral, and other pathogens. Findings from outbreak investigations and other studies have led to innovations in endoscope design, use, and reprocessing, yet infection risks related to contaminated or damaged endoscopes remain. Strict adherence to infection control guidelines and manufacturer instructions for use, utilization of supplemental guidance, and training and oversight of reprocessing personnel, reduce risk of pathogen transmission by flexible endoscopes.


Subject(s)
Centers for Disease Control and Prevention, U.S. , Cross Infection/prevention & control , Endoscopes, Gastrointestinal , Infection Control , Cross Infection/etiology , Disease Outbreaks/prevention & control , Endoscopes, Gastrointestinal/adverse effects , Endoscopes, Gastrointestinal/standards , Guideline Adherence , Guidelines as Topic , Humans , Infection Control/methods , Infection Control/standards , United States
15.
Infect Control Hosp Epidemiol ; 41(11): 1341-1343, 2020 11.
Article in English | MEDLINE | ID: mdl-32594923

ABSTRACT

We describe transmission of Klebsiella pneumoniae carbapenemase-producing Escherichia coli sequence type (ST) 1193 in a group home. E. coli ST1193 is an emerging multidrug-resistant clone not previously shown to carry carbapenemases in the United States. Our investigation illustrates the potential of residential group homes to amplify rare combinations of pathogens and resistance mechanisms.


Subject(s)
Bacterial Proteins , Klebsiella Infections , Klebsiella pneumoniae , beta-Lactamases , Anti-Bacterial Agents , Caregivers , Escherichia coli , Escherichia coli Infections , Humans , Klebsiella Infections/genetics , Klebsiella Infections/transmission , Klebsiella pneumoniae/genetics , Microbial Sensitivity Tests , Nevada
16.
J Clin Microbiol ; 58(9)2020 08 24.
Article in English | MEDLINE | ID: mdl-32493782

ABSTRACT

Pseudomonas aeruginosa is an opportunistic human pathogen that frequently causes health care-associated infections (HAIs). Due to its metabolic diversity and ability to form biofilms, this Gram-negative nonfermenting bacterium can persist in the health care environment, which can lead to prolonged HAI outbreaks. We describe the creation of a core genome multilocus sequence typing (cgMLST) scheme to provide a stable platform for the rapid comparison of P. aeruginosa isolates using whole-genome sequencing (WGS) data. We used a diverse set of 58 complete P. aeruginosa genomes to curate a set of 4,440 core genes found in each isolate, representing ∼64% of the average genome size. We then expanded the alleles for each gene using 1,991 contig-level genome sequences. The scheme was used to analyze genomes from four historical HAI outbreaks to compare the phylogenies generated using cgMLST to those of other means (traditional MLST, pulsed-field gel electrophoresis [PFGE], and single-nucleotide variant [SNV] analysis). The cgMLST scheme provides sufficient resolution for analyzing individual outbreaks, as well as the stability for comparisons across a variety of isolates encountered in surveillance studies, making it a valuable tool for the rapid analysis of P. aeruginosa genomes.


Subject(s)
Genome, Bacterial , Pseudomonas aeruginosa , Delivery of Health Care , Disease Outbreaks , Genome, Bacterial/genetics , Humans , Molecular Epidemiology , Multilocus Sequence Typing , Pseudomonas aeruginosa/genetics
17.
Clin Infect Dis ; 71(11): e718-e725, 2020 12 31.
Article in English | MEDLINE | ID: mdl-32291441

ABSTRACT

BACKGROUND: Since the identification of the first 2 Candida auris cases in Chicago, Illinois, in 2016, ongoing spread has been documented in the Chicago area. We describe C. auris emergence in high-acuity, long-term healthcare facilities and present a case study of public health response to C. auris and carbapenemase-producing organisms (CPOs) at one ventilator-capable skilled nursing facility (vSNF-A). METHODS: We performed point prevalence surveys (PPSs) to identify patients colonized with C. auris and infection-control (IC) assessments and provided ongoing support for IC improvements in Illinois acute- and long-term care facilities during August 2016-December 2018. During 2018, we initiated a focused effort at vSNF-A and conducted 7 C. auris PPSs; during 4 PPSs, we also performed CPO screening and environmental sampling. RESULTS: During August 2016-December 2018 in Illinois, 490 individuals were found to be colonized or infected with C. auris. PPSs identified the highest prevalence of C. auris colonization in vSNF settings (prevalence, 23-71%). IC assessments in multiple vSNFs identified common challenges in core IC practices. Repeat PPSs at vSNF-A in 2018 identified increasing C. auris prevalence from 43% to 71%. Most residents screened during multiple PPSs remained persistently colonized with C. auris. Among 191 environmental samples collected, 39% were positive for C. auris, including samples from bedrails, windowsills, and shared patient-care items. CONCLUSIONS: High burden in vSNFs along with persistent colonization of residents and environmental contamination point to the need for prioritizing IC interventions to control the spread of C. auris and CPOs.


Subject(s)
Candida , Skilled Nursing Facilities , Chicago/epidemiology , Follow-Up Studies , Humans , Illinois/epidemiology , Ventilators, Mechanical
18.
Infect Control Hosp Epidemiol ; 41(2): 226-228, 2020 02.
Article in English | MEDLINE | ID: mdl-31813410

ABSTRACT

Standardizing healthcare surface sampling requires the evaluation of sampling tools for organism adherence. Here, 7 sampling tools were evaluated to assess their elution efficiencies in the presence of 5 pathogens. Foam sponges (80.6%), microfiber wipes (80.5%), foam swabs (77.9%), and cellulose sponges (66.5%) yielded the highest median elution efficiencies.


Subject(s)
Bacteria/isolation & purification , Environmental Microbiology , Environmental Monitoring/instrumentation , Specimen Handling/instrumentation , Specimen Handling/methods
19.
Clin Infect Dis ; 71(7): e178-e185, 2020 10 23.
Article in English | MEDLINE | ID: mdl-31872853

ABSTRACT

BACKGROUND: In July 2018, the Arkansas Department of Health (ADH) was notified by hospital A of 3 patients with bloodstream infections (BSIs) with a rapidly growing nontuberculous Mycobacterium (NTM) species; on 5 September 2018, 6 additional BSIs were reported. All were among oncology patients at clinic A. We investigated to identify sources and to prevent further infections. METHODS: ADH performed an onsite investigation at clinic A on 7 September 2018 and reviewed patient charts, obtained environmental samples, and cultured isolates. The isolates were sequenced (whole genome, 16S, rpoB) by the Centers for Disease Control and Prevention to determine species identity and relatedness. RESULTS: By 31 December 2018, 52 of 151 (34%) oncology patients with chemotherapy ports accessed at clinic A during 22 March-12 September 2018 had NTM BSIs. Infected patients received significantly more saline flushes than uninfected patients (P < .001) during the risk period. NTM grew from 6 unused saline flushes compounded by clinic A. The identified species was novel and designated Mycobacterium FVL 201832. Isolates from patients and saline flushes were highly related by whole-genome sequencing, indicating a common source. Clinic A changed to prefilled saline flushes on 12 September as recommended. CONCLUSIONS: Mycobacterium FVL 201832 caused BSIs in oncology clinic patients. Laboratory data allowed investigators to rapidly link infections to contaminated saline flushes; cooperation between multiple institutions resulted in timely outbreak resolution. New state policies being considered because of this outbreak include adding extrapulmonary NTM to ADH's reportable disease list and providing more oversight to outpatient oncology clinics.


Subject(s)
Mycobacterium Infections, Nontuberculous , Neoplasms , Sepsis , Arkansas , Humans , Mycobacterium Infections, Nontuberculous/epidemiology , Neoplasms/complications , Nontuberculous Mycobacteria , Outpatients
20.
Am J Kidney Dis ; 74(5): 610-619, 2019 11.
Article in English | MEDLINE | ID: mdl-31375298

ABSTRACT

RATIONALE & OBJECTIVE: Contaminated water and other fluids are increasingly recognized to be associated with health care-associated infections. We investigated an outbreak of Gram-negative bloodstream infections at 3 outpatient hemodialysis facilities. STUDY DESIGN: Matched case-control investigations. SETTING & PARTICIPANTS: Patients who received hemodialysis at Facility A, B, or C from July 2015 to November 2016. EXPOSURES: Infection control practices, sources of water, dialyzer reuse, injection medication handling, dialysis circuit priming, water and dialysate test findings, environmental reservoirs such as wall boxes, vascular access care practices, pulsed-field gel electrophoresis, and whole-genome sequencing of bacterial isolates. OUTCOMES: Cases were defined by a positive blood culture for any Gram-negative bacteria drawn July 1, 2015 to November 30, 2016 from a patient who had received hemodialysis at Facility A, B, or C. ANALYTICAL APPROACH: Exposures in cases and controls were compared using matched univariate conditional logistic regression. RESULTS: 58 cases of Gram-negative bloodstream infection occurred; 48 (83%) required hospitalization. The predominant organisms were Serratia marcescens (n=21) and Pseudomonas aeruginosa (n=12). Compared with controls, cases had higher odds of using a central venous catheter for dialysis (matched odds ratio, 54.32; lower bound of the 95% CI, 12.19). Facility staff reported pooling and regurgitation of waste fluid at recessed wall boxes that house connections for dialysate components and the effluent drain within dialysis treatment stations. Environmental samples yielded S marcescens and P aeruginosa from wall boxes. S marcescens isolated from wall boxes and case-patients from the same facilities were closely related by pulsed-field gel electrophoresis and whole-genome sequencing. We identified opportunities for health care workers' hands to contaminate central venous catheters with contaminated fluid from the wall boxes. LIMITATIONS: Limited patient isolates for testing, on-site investigation occurred after peak of infections. CONCLUSIONS: This large outbreak was linked to wall boxes, a previously undescribed source of contaminated fluid and biofilms in the immediate patient care environment.


Subject(s)
Bacteremia/epidemiology , Cross Infection/epidemiology , Disease Outbreaks/statistics & numerical data , Gram-Negative Bacteria/isolation & purification , Gram-Negative Bacterial Infections/epidemiology , Renal Dialysis/adverse effects , Aged , Bacteremia/microbiology , Female , Follow-Up Studies , Gram-Negative Bacterial Infections/microbiology , Humans , Male , Middle Aged , Outpatients , Retrospective Studies , United States/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...