1.
Membranes (Basel) ; 12(12)2022 Dec 02.
Article in English | MEDLINE | ID: mdl-36557127

ABSTRACT

In this work, a novel and versatile experimental setup for coulometric signal transduction of ion-selective electrodes (ISEs) is introduced and studied. It is based on a constant potential coulometric measurement carried out using a one-compartment three-electrode electrochemical cell. In the setup, a potassium ion-selective electrode (K+- ISE) is connected as the reference electrode (RE). A poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate (PEDOT:PSS)-based electrode with a dummy membrane (DM) and a glassy carbon (GC) rod are connected as the working electrode (WE) and counter electrode (CE), respectively. Adding a non-selective dummy membrane to the structure of the WE facilitates the regulation of the measured signal and response time. The results from electrochemical impedance spectroscopy measurements carried out on the WE showed that the time constant is profoundly influenced by the dummy membrane thickness. In addition, the redox capacitance of the PEDOT:PSS film shows a better correlation with the electrode area than the film thickness. Sequential addition/dilution experiments showed the improvement of current and cumulated charge signals in the new setup studied in this work compared to the setup used in the original coulometric signal transduction method. Both conventional ISEs and solid-contact ISEs (SCISEs) were used in this work. The results showed that the coulometric response was independent of the type of ISE used as RE, confirming the versatility of the novel set-up.

2.
Membranes (Basel) ; 12(6)2022 May 30.
Article in English | MEDLINE | ID: mdl-35736276

ABSTRACT

In this study, the performance and long-time evaluation of solid-state composite (SSC) reference electrodes were investigated. The stability of all the SSC reference electrodes was continuously monitored by using potentiometry and electrochemical impedance spectroscopy methods over a period of several months. A multi-solution protocol was used to study the influence of the ionic strength of the sample solution, ion charge, and mobility, and the sample pH values on the performance of the reference electrodes. The SSC reference electrodes were used in the calibration of commercial indicator electrodes for different ions at different temperatures. The concentrations of K+, Na+, Ca2+, and Cl- ions and pH values were measured in river water samples at different temperatures using the SSC reference electrodes. The obtained results for the same samples were compared with the results given by an independent laboratory specialized in routine water analyses. The agreement between the results was very good and even better than the case where commercial reference electrodes were used. Our study showed that the SSC reference electrodes exhibit good long-term stability and excellent performance, both in the calibrations and analyses of environmental samples.

3.
Anal Chem ; 90(15): 9644-9649, 2018 08 07.
Article in English | MEDLINE | ID: mdl-29932635

ABSTRACT

The Nernst-Planck-Poisson model is used for modeling the sensitivity and selectivity of ion-selective electrodes (ISEs) with plastic membranes. Two pivotal parameters characterizing ISE response are in focus: sensitivity and selectivity. An interpretation of sensitivity, which considers the concurrent influence of anions and cations on the ISE slope, is presented. The interpretation of selectivity shows the validity and limits of approaches hitherto taken to measure the true (unbiased) selectivity coefficient. The validity of more idealized interpretations by the diffusion-layer model is conceived.

4.
Analyst ; 138(18): 5216-20, 2013 Sep 21.
Article in English | MEDLINE | ID: mdl-23846152

ABSTRACT

A new type of all-solid-state reference electrode was designed and characterized. The electrodes are based on a polymer/inorganic salt composite and a silver/silver chloride reference element. A rigorous testing procedure was used to reveal the possible influence of pH, solution composition, as well as the concentration and mobility of ions. The tests demonstrated the insensitivity of the electrodes to the matrix effects, excellent stability of the potential readings, and significantly reduced leakage of inorganic salt. In the performed tests the composite reference electrodes were on a par with or better than the high-quality commercial reference electrodes. The reference electrodes described here are of analytical quality allowing for continuous, prolonged, and intensive usage.