Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Dent Res J (Isfahan) ; 15(1): 25-32, 2018.
Article in English | MEDLINE | ID: mdl-29497444

ABSTRACT

Background: The aim of this study was to assess for the first time the effects of different amounts of ethanol solvent on the microtensile bond strength of composite bonded to dentin using a polyhedral oligomeric silsesquioxane (POSS)-incorporated adhesive. Materials and Methods: This experimental study was performed on 120 specimens divided into six groups (in accordance with the ISO TR11405 standard requiring at least 15 specimens per group). Occlusal dentin of thirty human molar teeth was exposed by removing its enamel. Five teeth were assigned to each of six groups and were converted to 20 microtensile rods (with square cross-sections of 1 mm × 1 mm) per group. The "Prime and Bond NT" (as a common commercial adhesive) was used as the control group. Experimental acrylate-based bonding agents containing 10 wt% POSS were produced with five concentrations of ethanol as solvent (0, 20, 31, 39, and 46 wt%). After application of adhesives on dentin surface, composite cylinders (height = 6 mm) were bonded to dentin surface. The microtensile bond strength of composite to dentin was measured. The fractured surfaces of specimens were evaluated under a scanning electron microscope to assess the morphology of hybrid layer. Data were analyzed using one-sample t-test, one-way analysis of variance (ANOVA), and Tukey tests (α = 0.05). Results: the mean bond strength in the groups: "control, ethanol-free, and 20%, 31%, 39%, and 46% ethanol" was, respectively, 46.5 ± 5.6, 29.4 ± 5.7, 33.6 ± 4.1, 59.0 ± 5.5, 41.9 ± 6.2, and 18.7 ± 4.6 MPa. Overall difference was significant (ANOVA, P < 0.0001). Pairwise differences were all significant (Tukey P < 0.05) except those of "ethanol 0% versus 20%" and "20% versus 31%." All groups except "0% and 46% ethanol" had bond strengths above 30 MPa (t-test P < 0.05). Conclusion: Incorporation of 31% ethanol as solvent into a 10 wt% POSS-incorporated experimental dental adhesive might increase the bond strength of composite to dentin and improve the quality and morphology of the hybrid layer. However, higher concentrations of the solvent might not improve the bond strength or quality of the hybrid layer.

2.
Dent Res J (Isfahan) ; 12(2): 150-6, 2015.
Article in English | MEDLINE | ID: mdl-25878680

ABSTRACT

BACKGROUND: Despite the growing tendency toward tooth-colored restorations in dentistry, polymerization shrinkage and subsequent marginal microleakage remains a problem. The aim of this in vitro study was to compare microleakage between silorane-based and methacrylate-based composite resins at different time intervals and with different restorative techniques. MATERIALS AND METHODS: In this in vitro study, 108 sound extracted human molar teeth were used. Mesial and distal proximal class II boxes with dimensions of 1.5 mm depth and 4 mm width were prepared. The gingival margins of all cavities were 1 mm below the cement enamel junction. The teeth were randomly divided into three groups based on test materials. In the first group, the teeth were restored by a nanocomposite (Filtek Z350XT, 3MESPE) and SE Bond adhesive (Kuraray, Japan), in the second group, the teeth were restored with a silorane-based (Filtek P90, 3MESPE) and Filtek P90 Adhesive (3M ESPE, USA) and in the third group, the teeth were restored with a microhybrid posterior composite resin (Filtek P60, 3MESPE) and SE Bond adhesive (Kuraray, Japan). Half of the proximal cavities in each of these three groups were restored in two horizontal layers and the other half in four horizontal layers. After a period of aging (24-h, 3-month and 6-month) in water and then application of 500 thermal cycles, the teeth were immersed for 24-h in 0.5% fuchsin and evaluated under a stereomicroscope at ×36 magnification to evaluate leakage in gingival margin. Data was statistically analyzed using Kruskal-Wallis and Mann-Whitney U-tests. P ≤ 0.05 was considered as significant. RESULTS: In Z350XT statistically significant differences were observed in microleakage in comparison of 24-h and 6-month intervals (P = 0.01) that was higher in 6-month. Comparison of microleakage in P90 and P60 composite resins was also statistically significant and was less in P90. Microleakage was not significantly different between P90 and Z350XT at 24-h. However, this difference was significant at 3-month and 6-month intervals. Differences in microleakage of P60 and Z-350XT composite resins were not statistically significant in all intervals (P = 0.38). P90 showed the lowest microleakage during storage in water. Z350XT had microleakage similar to P90 within 24-h, but after 6-month of storage in water, it showed the highest microleakage among all the groups. The number of layers (2 layers vs. 4 layers) did not result in any differences in microleakage scores of the composite resins (P = 0.42). CONCLUSION: Water storage times did not result in any significant effect on microleakage of P90 and P60.

3.
Open Dent J ; 8: 144-7, 2014.
Article in English | MEDLINE | ID: mdl-25228939

ABSTRACT

INTRODUCTION: Hardness is one of the basic properties of dental materials, specially composite resins which is relevant to their polymerization. The aim of this study was to evaluate the effect of light curing distance and the color of clear Mylar strips on surface hardness of Silorane-based (SCR) and Methacrylate-based composite resins (MCR). MATERIALS AND METHODS: 40 samples of MCRs (Filtek Z250) and SCRs (Filtek P90) were prepared in size of 5 mm×2 mm (80 samples in total). The samples divided into 8 groups (10 samples in each one) based on the color of clear Mylar strips (white or blue) and distance from light curing source (0 mm or 2 mm). All the samples cured for 40 second and stored in incubator for 24 hours in 37°C temperature. Surface hardness test was done by Vickers test machine and the collected data were analyzed by one-way ANOVA and paired T-test by using SPSS software version 13 at significant level of 0.05. RESULTS: MCRs cured with blue Mylar strips from 0 mm distance had the highest (114.5 kg/mm(2)) and SCRs cured with white Mylar strips from 2 mm distance had the lowest (42.2 kg/mm(2)) mean of surface hardness. Also, the results of comparison among SCRs and MCRs showed significant differences among all groups (all P values <0.01). CONCLUSION: The hardness decreased as the distance increased and the blue Mylar strips provided higher hardness than clear ones. Also, Filtek Z250 showed higher hardness compared to Filtek P90.

4.
Open Dent J ; 5: 52-7, 2011 Mar 29.
Article in English | MEDLINE | ID: mdl-21566692

ABSTRACT

OBJECTIVES: To compare the microleakage among experimental adhesives containing nanoclay fillers after the storages of 24 hours and 6 months. MATERIALS AND METHODS: Class V cavities were prepared on extracted human molars with the occlusal margins located in enamel and the cervical margins in cementum. Phosphoric acid was applied to the enamel and dentin margins.Subsequently, the cavities were treated using four groups of experimental adhesive systems and restored with a resin composite. Adper Single Bond® was used as control group. After 24- hour and 6- month storages, the samples were subjected to thermocycling shocks and then immersed in silver nitrate as well as developer solution and finally evaluated for leakage. The data were analyzed using SPSS software. RESULTS: Based on Kruskal -Wallis test, significant differences were found between groups regarding microleakage. The Mann- Whitney test showed that Leakage was significantly lower in Adper Single Bond® compared to the other groups in dentinal margins after 24 hours and 6 months and in enamel margins after 6 months. The Wilcoxon Signed Ranks test showed that the enamel leakage in experimental adhesives was significantly lower than dentinal leakage after 24 hours as well as enamel leakage in Adper Single Bond and adhesive with 0.5% PMAA-g-nanoclay was significantly lower than dentinal margins after storage period of 6 months. CONCLUSION: All the experimental adhesives were effective in reducing enamel leakage after 24 hours, but were not effective in reducing dentinal leakage after 24 hours as well as in enamel and dentinal leakage after a 6-month storage. No improvement was observed in the microleakage in dentin in both short (24 hrs) and long times (6 months). The high microleakage in the adhesives is probably attributed to the high concentration of HEMA in the recipe of the bonding agent.

5.
Article in English | MEDLINE | ID: mdl-23230474

ABSTRACT

BACKGROUND AND AIMS: The aim of the present study was to compare the efficacy of quartz tungsten halogen (QTH) and light emitting diode (LED) curing lights on polymerization of resin composite. MATERIALS AND METHODS: A hybrid resin composite was used to prepare samples which were cured using two QTH and ten LED light curing sources. Twelve groups, each containing ten samples, were prepared using each light source. The cured depth of the resin was determined using ISO 4049 method and Vickers hardness values were determined at 1.0 mm intervals. Data was analyzed by ANOVA and Tukey test. RESULTS: Data analysis demonstrated a significant difference between light sources for depth of cure. At 1.0 mm below the surface all the tested light sources and at 2.0-mm intervals all light sources except two (Optilux 501 and LEDemetron I) and at 3.0-mm intervals only two light sources (PenCure and LEDemetron II) could produce hardness values higher than 80% of superficial layer values. CONCLUSION: This study showed that a variety of LED light sources used in the present study are as effective as the high-intensity QTH lights in polymerization of resin composite.

6.
Dent Res J (Isfahan) ; 6(1): 29-37, 2009.
Article in English | MEDLINE | ID: mdl-21528027

ABSTRACT

BACKGROUND: Along with development of different dental adhesives, concerns about hydrolytic deg-radation of the adhesive components have arisen. The purpose of this study was to evaluate the in vitro influence of thermocycling, water storage and resin coating on the microshear bond strength of total etch and self etch adhesive systems to dentin. METHODS: The superficial coronal dentin of eighty intact third molars were exposed and divided into 5 equal groups. Dental adhesives including Scotch Bond Multi Purpose (SBMP), Single Bond (SB), Clearfil SE Bond (CSE), Prompt L-Pop (PLP), and Prompt L-Pop plus Margin bond (PLPM) were applied according to the manufacturers' instructions on prepared surfaces in the study groups, respectively. Then composite cylinders were bonded and specimens were divided into two subgroups. One subgroup was stored in water for 24 hours. The second subgroup was subjected to 3000 thermocycle shocks and then was stored in 37°C water for 3 months. Finally, all teeth were subjected to the microshear bond strength test. Data were analyzed using two-way ANOVA and Tukey HSD tests. One specimen similar to each subgroup was also prepared for SEM evaluation. RESULTS: After one-day storage, the SBMP showed the highest bond strength followed by CSE, PLPM, SB and PLP. After three months storage, the highest bond strength was observed in SBMP followed by PLPM, CSE, SB, and PLP. CONCLUSION: SBMP showed the best bond strength while CSE represented acceptable bond durability. Resin coating on PLP improved bond strength and durability.

SELECTION OF CITATIONS
SEARCH DETAIL
...