Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Orthop Res ; 42(7): 1501-1508, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38414362

ABSTRACT

Widely varying prevalence of vitamin D deficiency has been reported in patients presenting for total knee arthroplasty (TKA). The primary aim of this study was to determine vitamin D levels in TKA patients and to compare to patients already routinely evaluated for vitamin D levels, patients with fragility fractures of the distal radius (DRF). There is significant overlap between patients presenting for TKA and with DRF, both in terms of medical comorbidities and overall health status, making these populations suitable comparative cohorts. Wefound that all patients presenting for TKA consultation had vitamin D insufficiency and 33% had vitamin D deficiency, compared to only 37% and 14% in the DRF cohort, a patient population routinely evaluated for vitamin D due to the high risk of deficiency. Furthermore, patients with DRF had higher levels of vitamin D before (38 ± 16 vs. 23 ± 5) and after vitamin D supplementation (39 ± 17 vs. 33 ± 10), suggesting that patients presenting for TKA are at even higher risk of vitamin D insufficiency than patients presenting with DRF. Reassuringly, supplementation successfully corrected 39.0% and 55.8% of patients in the DRF and TKA cohorts, respectively.


Subject(s)
Arthroplasty, Replacement, Knee , Vitamin D Deficiency , Humans , Vitamin D Deficiency/complications , Vitamin D Deficiency/epidemiology , Arthroplasty, Replacement, Knee/adverse effects , Aged , Female , Male , Middle Aged , Vitamin D/blood , Aged, 80 and over
2.
Hand (N Y) ; : 15589447231164746, 2023 Apr 19.
Article in English | MEDLINE | ID: mdl-37077124

ABSTRACT

BACKGROUND: De Quervain tenosynovitis of the wrist is a common pathology. The primary aim of this study is to determine the prevalence of extensor pollicis brevis and abductor pollicis longus (APL) anatomical variations in association with de Quervain tenosynovitis. The secondary aim was to compare additional patient-specific factors associated with de Quervain tenosynovitis. METHODS: This retrospective study included 172 patients with de Quervain tenosynovitis who underwent first dorsal compartment release and 179 patients with thumb carpometacarpal (CMC) arthritis who underwent thumb CMC arthroplasty between August 1, 2007, and May 1, 2022. The CMC group was chosen as the control group because the study surgeons perform APL suspensionplasty as the primary procedure for thumb CMC arthritis, allowing for a comparison group without de Quervain tenosynovitis. Exclusion criteria included patients undergoing revision surgery, patients undergoing thumb CMC procedure other than APL suspensionplasty, and patients with both CMC and first dorsal compartment diagnoses. Demographics, clinical variables, and intraoperative findings were collected through retrospective chart reviews. RESULTS: Patients in the de Quervain tenosynovitis group tended to be younger (51 years, range: 23-92 years vs 63 years, range: 28-85 years), women (86.1% vs 77.1%), and more commonly of African American or black race (15.7% vs 3.9%) and Asian race (5.2% vs 0%). There was a higher prevalence of tendon subcompartments (79.1% vs 64.2%), but fewer number of APL slips (38.3% vs 20.7% 2 or fewer slips) seen in the de Quervain tenosynovitis group. CONCLUSION: Anatomical variation exists between patients with and without de Quervain tenosynovitis. The presence of tendon subcompartments but not an increased number of tendon slips is associated with de Quervain tenosynovitis.

3.
Ann Biomed Eng ; 51(8): 1738-1746, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36966247

ABSTRACT

Single ventricle physiology (SVP) is used to describe any congenital heart lesion that is unable to support independent pulmonary and systemic circulations. Current treatment strategies rely on a series of palliation surgeries that culminate in the Fontan physiology, which relies on the single functioning ventricle to provide systemic circulation while passively routing venous return through the pulmonary circulation. Despite significant reductions in early mortality, the presence of atrioventricular valve (AVV) regurgitation is a key predictor of heart failure in these patients. We sought to evaluate the biomechanical changes associated with the AVV in SVP physiologies. Left and right ventricles were sutured onto patient-derived 3D-printed mounts and mounted into an ex vivo systemic heart simulator capable of reproducing Norwood, Glenn, Fontan and Late Fontan physiologies. We found that the tricuspid anterior leaflet experienced elevated maximum force, average force, and maximum yank compared to the posterior and septal leaflets. Between physiologies, maximum yank was greatest in the Norwood physiology relative to the Glenn, Fontan, and Late Fontan physiologies. These contrasting trends suggest that long- and short-term mechanics of AVV failure in single ventricle differ and that AVV interventions should account for asymmetries in force profiles between leaflets and physiologies.


Subject(s)
Fontan Procedure , Heart Defects, Congenital , Humans , Treatment Outcome , Retrospective Studies , Heart Valves , Heart Ventricles
4.
Article in English | MEDLINE | ID: mdl-36455710

ABSTRACT

We sought to understand how leaflet forces change in response to annular dilation and leaflet tethering (LT) in single ventricle physiology. Explanted fetal bovine tricuspid valves were sutured onto image-derived annuli and ventricular mounts. Control valves (CON) were secured to a size-matched hypoplastic left heart syndrome (HLHS)-type annulus and compared to: (1) normal tricuspid valves secured to a size-matched saddle-shaped annulus, (2) HLHS-type annulus with LT, (3) HLHS-type annulus with annular dilation (dilation valves), or (4) a combined disease model with both dilation and tethering (disease valves). The specimens were tested in a systemic heart simulator at various single ventricle physiologies. Leaflet forces were measured using optical strain sensors sutured to each leaflet edge. Average force in the anterior leaflet was 43.2% lower in CON compared to normal tricuspid valves (P < 0.001). LT resulted in a 6.6% increase in average forces on the anterior leaflet (P = 0.04), 10.7% increase on the posterior leaflet (P = 0.03), and 14.1% increase on the septal leaflet (P < 0.001). In dilation valves, average septal leaflet forces increased relative to the CON by 42.2% (P = 0.01). In disease valves, average leaflet forces increased by 54.8% in the anterior leaflet (P < 0.001), 37.6% in the posterior leaflet (P = 0.03), and 79.9% in the septal leaflet (P < 0.001). The anterior leaflet experiences the highest forces in the normal tricuspid annulus under single ventricle physiology conditions. Annular dilation resulted in an increase in forces on the septal leaflet and LT resulted in an increase in forces across all 3 leaflets. Annular dilation and LT combined resulted in the largest increase in leaflet forces across all 3 leaflets.

5.
World J Pediatr Congenit Heart Surg ; 13(2): 166-174, 2022 03.
Article in English | MEDLINE | ID: mdl-35238706

ABSTRACT

BACKGROUND: Neo-aortic pulmonary autografts often experience root dilation and valve regurgitation over time. This study seeks to understand the biomechanical differences between aortic and neo-aortic pulmonary roots using a heart simulator. METHODS: Porcine aortic, neo-aortic pulmonary, and pulmonary roots (n = 6) were mounted in a heart simulator (parameters: 100 mm Hg, 37 °C, 70 cycles per minute, 5.0 L/min cardiac output). Echocardiography was used to study root distensibility (percentage change in luminal diameter between systole and diastole) and valve function. Leaflet motion was tracked with high-speed videography. After 30 min in the simulator, leaflet thickness (via cryosectioning), and multiaxial modulus (via lenticular hydrostatic deformation testing) were obtained. RESULTS: There were no significant differences between aortic and neo-aortic pulmonary leaflet motion, including mean opening velocity (218 vs 248 mm/s, P = .27) or mean closing velocity (116 vs 157 mm/s, P = .12). Distensibility was similar between aortic (8.5%, 1.56 mm) and neo-aortic pulmonary (7.8%, 1.12 mm) roots (P = .59). Compared to virgin controls, native pulmonic roots exposed to systemic pressure for 30 min had reduced leaflet thickness (630 vs 385 µm, P = .049) and a reduced Young's modulus (3,125 vs 1,089 kPa, P = .077). In contrast, the aortic roots exposed to pressure displayed no significant difference in aortic leaflet thickness (1,317 vs 1,256 µm, P = .27) or modulus (5,931 vs 3,631 kPa, P = .56). CONCLUSIONS: Neo-aortic pulmonary roots demonstrated equivalence in valve function and distensibility but did experience changes in biomechanical properties and morphology. These changes may contribute to long-term complications associated with the Ross procedure.


Subject(s)
Aortic Valve Insufficiency , Heart Valve Diseases , Pulmonary Valve , Animals , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Autografts , Heart Valve Diseases/surgery , Humans , Pulmonary Valve/transplantation , Swine , Transplantation, Autologous/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...