1.
Rev Sci Instrum ; 93(11): 113533, 2022 Nov 01.
Article in English | MEDLINE | ID: mdl-36461464

ABSTRACT

A 2D imaging instrument has been designed and deployed on C-2W ("Norman") [H. Gota et al., Nucl. Fusion 61, 106039 (2021)] to study the plasma in the expander divertor by simultaneously measuring three neutral helium spectral lines. Ratios of these images, in conjunction with a collisional-radiative model, yield 2D maps of electron temperature and density. Almost the entire radial plasma cross-section (∼60 cm) can be mapped with a spatial resolution ≲1 cm. These data can, in principle, be acquired at 3 kHz. The neutral helium target is provided by a custom-built supersonic gas injector located inside the divertor vessel, which injects helium toward the magnetic axis and perpendicular to the camera sight-cone. Images of helium emission and reconstructed electron density and temperature profiles of the plasma produced from an end gun are presented. Voltages applied to concentric annular electrodes located in the divertors are used to stabilize beam-driven field reversed configuration plasmas. Magnetic field expansion is also employed to thermally isolate electrons from the end electrodes. Measurements of electron temperature and density in the divertor are important in order to study the effects of both the electrostatic biasing and the divertor magnetic field on electron confinement, neutral gas transport, and the overall machine performance.

2.
Rev Sci Instrum ; 89(10): 10D102, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399953

ABSTRACT

The thermal helium beam edge diagnostic has recently been upgraded at the ASDEX Upgrade (AUG) tokamak experiment. Line ratio spectroscopy on neutral helium is a valuable tool for simultaneous determination of the electron temperature and density of plasmas. The diagnostic now offers a temporal resolution of 900 kHz with a spatial resolution of up to 3 mm at 32 lines of sight (LOS) simultaneously. The LOS covers a radial region of 8.5 cm, starting at the limiter radius and reaching into the confined region beyond the separatrix. Two components are of particular importance for the aforementioned hardware improvements. The first is the optical head, which collects the light from the experiment. Equipped with an innovative clamping system for optical fiber ends, an arbitrary distribution pattern of LOS can be achieved to gain radial and poloidal profiles. The second major development is a new polychromator system that measures the intensity of the 587 nm, 667 nm, 706 nm, and 728 nm helium lines simultaneously for 32 channels with filter-photomultiplier tube arrays. Thus, the thermal helium beam diagnostic supplements the AUG edge diagnostics, offering fast and spatially highly resolved electron temperature and density profile measurements that cover the plasma edge and scrape-off layer region. Plasma fluctuations, edge localized modes, filaments, and other turbulent structures are resolved, allowing analysis of their frequency and localization or their propagation velocity.

3.
Rev Sci Instrum ; 87(11): 11E554, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910613

ABSTRACT

A beam emission spectroscopy system on thermal helium (He) and neon (Ne) has been set up at Wendelstein 7-X to measure edge electron temperature and density profiles utilizing the line-ratio technique or its extension by the analysis of absolutely calibrated line emissions. The setup for a first systematic test of these techniques of quantitative atomic spectroscopy in the limiter startup phase (OP1.1) is reported together with first measured profiles. This setup and the first results are an important test for developing the technique for the upcoming high density, low temperature island divertor regime.

4.
Rev Sci Instrum ; 87(11): 11E502, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910657

ABSTRACT

Helium line-ratios for electron temperature (Te) and density (ne) plasma diagnostic in the Scrape-Off-Layer (SOL) and edge regions of tokamaks are widely used. Due to their intensities and proximity of wavelengths, the singlet, 667.8 and 728.1 nm, and triplet, 706.5 nm, visible lines have been typically preferred. Time-dependency of the triplet line (706.5 nm) has been previously analyzed in detail by including transient effects on line-ratios during gas-puff diagnostic applications. In this work, several line-ratio combinations within each of the two spin systems are analyzed with the purpose of eliminating transient effects to extend the application of this powerful diagnostic to high temporal resolution characterization of plasmas. The analysis is done using synthetic emission modeling and diagnostic for low electron density NSTX SOL plasma conditions by several visible lines. Quasi-static equilibrium and time-dependent models are employed to evaluate transient effects of the atomic population levels that may affect the derived electron temperatures and densities as the helium gas-puff penetrates the plasma. The analysis of a wider range of spectral lines will help to extend this powerful diagnostic to experiments where the wavelength range of the measured spectra may be constrained either by limitations of the spectrometer or by other conflicting lines from different ions.

5.
Rev Sci Instrum ; 83(10): 10D508, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126851

ABSTRACT

Four collisional radiative models (CRMs) for reconstruction of the edge electron density profile from the measured Li I (2s-2p) emission profile of an accelerated lithium beam are compared using experimental data from DIII-D. It is shown for both L- and H-mode plasmas that edge density profiles reconstructed with the CRMs DDD2, ABSOLUT, [Sasaki et al. Rev. Sci. Instrum. 64, 1699 (1993)] and a new model developed at DIII-D agree in a density scan from n(e) (ped) = (2.0-6.5) × 10(19) m(-3) within 20%, 20%, <5%, and 40%, respectively, of the pedestal density measured with Thomson scattering. Profile shape and absolute density vary in a scan of the effective ion charge Z(eff) = 1-6 up to a factor of two but agree with Thomson data for Z(eff) = 1-2 within the error bars.

6.
Rev Sci Instrum ; 83(10): 10D518, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126859

ABSTRACT

Neutral beams based on positive ion source technology are a key component of contemporary fusion research. An accurate assessment of the injected beam species mix is important for determining the actual plasma heating and momentum input as well as proper interpretation of beam-based diagnostics. On DIII-D, the main ion charge-exchange spectroscopy system is used to extract well-resolved intensity ratios of the Doppler-shifted D(α) emission from the full, half, and third energy beam components for a variety of beam operational parameters. In conjunction with accurate collisional-radiative modeling, these measurements indicate the assumed species mix and power fractions can vary significantly and should be regularly monitored and updated for the most accurate interpretation of plasma performance. In addition, if stable active control of the power fractions can be achieved through appropriate source tuning, the resulting control over the deposition profile can serve as an additional experimental knob for advanced tokamak studies, e.g., varying the off axis beam current drive without altering the beam trajectory.

7.
Rev Sci Instrum ; 83(10): 10D529, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126869

ABSTRACT

The neutral-beam induced D(α) emission spectrum contains a wealth of information such as deuterium ion temperature, toroidal rotation, density, beam emission intensity, beam neutral density, and local magnetic field strength magnitude |B| from the Stark-split beam emission spectrum, and fast-ion D(α) emission (FIDA) proportional to the beam-injected fast ion density. A comprehensive spectral fitting routine which accounts for all photoemission processes is employed for the spectral analysis. Interpretation of the measurements to determine physically relevant plasma parameters is assisted by the use of an optimized viewing geometry and forward modeling of the emission spectra using a Monte-Carlo 3D simulation code.

8.
Rev Sci Instrum ; 83(10): 10D722, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126896

ABSTRACT

Radial profiles of electron temperature and density are measured at high spatial (∼1 mm) and temporal (≥10 µs) resolution using a thermal supersonic helium jet. A highly accurate detection system is applied to well-developed collisional-radiative model codes to produce the profiles. Agreement between this measurement and an edge Thomson scattering measurement is found to be within the error bars (≲20%). The diagnostic is being used to give profiles near the ion cyclotron resonant heating antenna on TEXTOR to better understand RF coupling to the core.