Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Radiat Oncol ; 15(1): 28, 2020 Jan 31.
Article in English | MEDLINE | ID: mdl-32005123

ABSTRACT

INTRODUCTION: Colorectal cancer treatment requires a complex, multidisciplinary approach. Because of the potential variability, monitoring through clinical audits is advisable. This study assesses the effects of a quality improvement action plan in patients with locally advanced rectal cancer and treated with radiotherapy. METHODS: Comparative, multicentre study in two cohorts of 120 patients each, selected randomly from patients diagnosed with rectal cancer who had initiated radiotherapy with a curative intent. Based on the results from a baseline clinical audit in 2013, a quality improvement action plan was designed and implemented; a second audit in 2017 evaluated its impact. RESULTS: Standardised information was present on 77.5% of the magnetic resonance imaging (MRI) staging reports. Treatment strategies were similar in all three study centres. Of the patients whose treatment was interrupted, just 9.7% received a compensation dose. There was an increase in MRI re-staging from 32.5 to 61.5%, and a significant decrease in unreported circumferential resection margins following neoadjuvant therapy (ypCRM), from 34.5 to 5.6% (p <  0.001). CONCLUSIONS: The comparison between two clinical audits showed improvements in neoadjuvant radiotherapy in rectal cancer patients. Some indicators reveal areas in need of additional efforts, for example to reduce the overall treatment time.


Subject(s)
Adenocarcinoma/radiotherapy , Carcinoma, Squamous Cell/radiotherapy , Delivery of Health Care/standards , Neoadjuvant Therapy/mortality , Quality Improvement , Radiotherapy, Adjuvant/mortality , Rectal Neoplasms/radiotherapy , Adenocarcinoma/pathology , Aged , Aged, 80 and over , Carcinoma, Squamous Cell/pathology , Female , Humans , Male , Middle Aged , Prognosis , Rectal Neoplasms/pathology , Survival Rate
2.
Transl Oncol ; 11(3): 794-799, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29704788

ABSTRACT

BACKGROUND: The therapeutic approach to cancer is complex and multidisciplinary. Radiotherapy is among the essential treatments, whether used alone or in conjunction with other therapies. This study reports a clinical audit of the radiotherapy process to assess the process of care, evaluate adherence to agreed protocols and measure the variability to improve therapeutic quality for rectal cancer. METHODS: Multicentre retrospective cohort study in a representative sample of patients diagnosed with rectal cancer in the Institut Català d'Oncologia, a comprehensive cancer centre with three different settings. We developed a set of indicators to assess the key areas of the radiotherapy process. The clinical audit consisted of a review of a random sample of 40 clinical histories for each centre. RESULTS: The demographic profile, histology and staging of patients were similar between centres. The MRI reports did not include the distance from tumour to mesorectal fascia (rCRM) in 38.3% of the cases. 96.7% of patients received the planned dose, and 57.4% received it at the planned time. Surgery followed neoadjuvant treatment in 96.7% of the patients. Among this group, postoperative CRM was recorded in 65.5% of the cases and was negative in 93.4% of these. With regard to the 34.5% (n = 40) of cases where no CRM value was stated, there were differences between the centres. Mean follow-up was 3.4 (SD 0.6) years, and overall survival at four years was 81.7%. CONCLUSIONS: The audit revealed a suboptimal degree of adherence to clinical practice guidelines. Significant variability between centres exists from a clinical perspective but especially with regard to organization and process.

3.
Med Phys ; 41(8): 081710, 2014 Aug.
Article in English | MEDLINE | ID: mdl-25086520

ABSTRACT

PURPOSE: The aim of this study was to evaluate the suitability of several detectors for the determination of absorbed dose in bone. METHODS: Three types of ultrathin LiF-based thermoluminescent dosimeters (TLDs)-two LiF:Mg,Cu,P-based (MCP-Ns and TLD-2000F) and a (7)Li-enriched LiF:Mg,Ti-based (MTS-7s)-as well as EBT2 Gafchromic films were used to measure percentage depth-dose distributions (PDDs) in a water-equivalent phantom with a bone-equivalent heterogeneity for 6 and 18 MV and a set of field sizes ranging from 5 x 5 cm2 to 20 x 20 cm2. MCP-Ns, TLD-2000F, MTS-7s, and EBT2 have active layers of 50, 20, 50, and 30 µm, respectively. Monte Carlo (MC) dose calculations (PENELOPE code) were used as the reference and helped to understand the experimental results and to evaluate the potential perturbation of the fluence in bone caused by the presence of the detectors. The energy dependence and linearity of the TLDs' response was evaluated. RESULTS: TLDs exhibited flat energy responses (within 2.5%) and linearity with dose (within 1.1%) within the range of interest for the selected beams. The results revealed that all considered detectors perturb the electron fluence with respect to the energy inside the bone-equivalent material. MCP-Ns and MTS-7s underestimated the absorbed dose in bone by 4%-5%. EBT2 exhibited comparable accuracy to MTS-7s and MCP-Ns. TLD-2000F was able to determine the dose within 2% accuracy. No dependence on the beam energy or field size was observed. The MC calculations showed that a[Formula: see text] thick detector can provide reliable dose estimations in bone regardless of whether it is made of LiF, water or EBT's active layer material. CONCLUSIONS: TLD-2000F was found to be suitable for providing reliable absorbed dose measurements in the presence of bone for high-energy x-ray beams.


Subject(s)
Bone and Bones/radiation effects , Radiometry/instrumentation , Biomimetic Materials/radiation effects , Calibration , Computer Simulation , Dose-Response Relationship, Drug , Electrons , Equipment Design , Fluorides , Linear Models , Lithium Compounds , Models, Biological , Monte Carlo Method , Phantoms, Imaging , Radiometry/methods , Water , X-Rays
SELECTION OF CITATIONS