Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Osteoporos Int ; 2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38900165

ABSTRACT

Our study investigates vertebral fractures in individuals with distal radius fractures. Among 512 patients, 41.21% had vertebral fractures, predominantly in the lumbar spine. These findings highlight the importance of screening for vertebral fractures in this population, informing early intervention strategies to mitigate risks associated with osteoporosis. PURPOSE: This study's main goal was to look into the frequency, location, kind, and severity of asymptomatic vertebral fragility fractures (VFF) in people who had fractures of the fragility of the distal radius. Although VFF is frequently misdiagnosed, it is linked to higher mortality, morbidity, and hip fracture risk. The study also attempted to investigate the relationship between VFF and certain demographic and lifestyle factors, as well as FRAX data, in this patient population. METHODS: Between January, 2021, and January, 2022, individuals with low-energy distal radial fractures who presented to the emergency room of tertiary care hospital of Karachi, Pakistan, were the subject of a cross-sectional study and were 45 years of age or older except those who fitted the exclusion criteria (n = 208). The thoracic and/or lumbar spine was imaged using radiology, and information on demographics, way of life, and FRAX (Fracture Risk Assessment Tool) was gathered. Using the Genant semiquantitative approach, an impartial and blinded orthopaedist identified VF in the images and determined their severity. SPSS version 20 was used to analyse the data. RESULTS: Two hundred eleven (41.21%) of them were found to have radiographic VFF and only 12 (2.34%) of the 512 patients who were tested were getting osteoporotic therapy. The thoracic spine (32.7%), followed by the lumbar spine (43.12%), was the area most frequently afflicted. In 24.17% of the patients, multiple fractures of the thoracolumbar spine were found. The wedge form (54.5%), followed by biconcave (30.81%) and crush (14.7%), was the most prevalent VFF type. The majority of detected VFF were rated as having a 25-40% height loss (64.9%) then severe (> 40%) fractures (35.1%), according to the Genant grading method. Notably, there were no variations in smoking, drinking, BMI, or FRAX score between patients with and without VFF that were statistically significant. CONCLUSION: Based on our study's findings, it is clear that osteoporotic vertebral fragility fractures occur in almost half of individuals with distal radius fractures. The lumbar spine is notably the most affected region, predominantly with wedge fractures. Given the high prevalence of asymptomatic vertebral fragility fractures (VFF), proactive measures are necessary to mitigate associated risks. Prioritising comprehensive fall risk assessments for these patients and interventions to enhance bone mineral density and strength are crucial. Early identification of asymptomatic VFF enables timely intervention, optimising patient care and minimising the risk of complications in this vulnerable population.

2.
Cureus ; 15(8): e44314, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37779743

ABSTRACT

Our study assessed the efficacy and safety of the three primary tirzepatide (TZP) doses, 5 mg, 10 mg, and 15 mg using network meta-analysis to assess their relative impact on type 2 diabetes mellitus (T2DM) treatment. This study adhered to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guidelines. Two authors independently screened online databases, including PubMed, Cochrane Library, and Embase. We employed the keywords "Type 2 diabetes OR T2DM or diabetes" AND "Tirzepatide OR LY3298176 OR twincretin OR dual glucose-dependent insulinotropic polypeptide and glucagon-like peptide-1 receptor agonist" AND "randomized controlled trial". The outcomes evaluated in this study comprised changes in hemoglobin (Hb)A1c levels from baseline (%), changes in weight from baseline (Kg), changes in fasting serum glucose from baseline (mg/dL), and occurrences of serious adverse events (SAE), adverse events (AE) and major adverse cardiovascular events (MACE). A total of eight studies met the inclusion criteria and were included in this meta-analysis. Our findings suggest that among the evaluated doses, TZP at 15 mg demonstrated superior effectiveness in reducing HbA1c, weight, and fasting serum glucose compared to doses of 10 mg and 5 mg. Notably, the reduction in HbA1c and weight showed a dose-dependent trend, with the 15 mg dose achieving the most substantial benefits. The safety analysis indicated that while serious adverse events and major adverse cardiovascular events (MACE) did not significantly differ among the three doses, the risk of overall adverse events was notably higher in the 10 mg and 15 mg TZP groups compared to the 5 mg group.

3.
Polymers (Basel) ; 15(1)2022 Dec 21.
Article in English | MEDLINE | ID: mdl-36616375

ABSTRACT

The current energy crisis and waste management problems have compelled people to find alternatives to conventional non-renewable fuels and utilize waste to recover energy. Pyrolysis of plastics, which make up a considerable portion of municipal and industrial waste, has emerged as a feasible resolution to both satisfy our energy needs and mitigate the issue of plastic waste. This study was therefore conducted to find a solution for plastic waste management problems, as well as to find an alternative to mitigate the current energy crisis. Pyrolysis of five of the most commonly used plastics, polyethylene terephthalate (PET), high- and low-density polyethylene (HDPE, LDPE), polypropylene (PP), and polystyrene (PS), was executed in a pyrolytic reactor designed utilizing a cylindrical shaped stainless steel container with pressure and temperature gauges and a condenser to cool down the hydrocarbons produced. The liquid products collected were highly flammable and their chemical properties revealed them as fuel alternatives. Among them, the highest yield of fuel conversion (82%) was observed for HDPE followed by PP, PS, LDPE, PS, and PET (61.8%, 58.0%, 50.0%, and 11.0%, respectively). The calorific values of the products, 46.2, 46.2, 45.9, 42.8 and 42.4 MJ/kg for LPDE, PP, HPDE, PS, and PET, respectively, were comparable to those of diesel and gasoline. Spectroscopic and chromatographic analysis proved the presence of alkanes and alkenes with carbon number ranges of C9-C15, C9-C24, C10-C21, C10-C28, and C9-C17 for PP, PET, HDPE, LDPE, and PS, respectively. If implemented, the study will prove to be beneficial and contribute to mitigating the major energy and environmental issues of developing countries, as well as enhance entrepreneurship opportunities by replicating the process at small-scale and industrial levels.

4.
Plast Reconstr Surg Glob Open ; 9(5): e3568, 2021 May.
Article in English | MEDLINE | ID: mdl-34881144

ABSTRACT

Various modalities to facilitate nerve regeneration have been described in the literature with limited success. We hypothesized that negative pressure applied to a sectioned peripheral nerve would enhance nerve regeneration by promoting angiogenesis and axonal lengthening. METHODS: Wistar rats' sciatic nerves were cut (creating ~7 mm nerve gap) and placed into a silicone T-tube, to which negative pressure was applied. The rats were divided into 4 groups: control (no pressure), group A (low pressure: 10 mm Hg), group B (medium pressure: 20/30 mm Hg) and group C (high pressure: 50/70 mm Hg). The nerve segments were retrieved after 7 days for gross and histological analysis. RESULTS: In total, 22 rats completed the study. The control group showed insignificant nerve growth, whereas the 3 negative pressure groups showed nerve growth and nerve gap reduction. The true nerve growth was highest in group A (median: 3.54 mm) compared to group B, C, and control (medians: 1.19 mm, 1.3 mm, and 0.35 mm); however, only group A was found to be significantly different to the control group (**P < 0.01). Similarly, angiogenesis was observed to be significantly greater in group A (**P < 0.01) in comparison to the control. CONCLUSIONS: Negative pressure stimulated nerve lengthening and angiogenesis within an in vivo rat model. Low negative pressure (10 mm Hg) provided superior results over the higher negative pressure groups and the control, favoring axonal growth. Further studies are required with greater number of rats and longer recovery time to assess the functional outcome.

5.
Cureus ; 12(11): e11480, 2020 Nov 14.
Article in English | MEDLINE | ID: mdl-33329976

ABSTRACT

Background Chorionic bump is a rare condition defined as a bulge or protrusion from the choriodecidual surface into the gestational sac. The limited literature on this infrequent entity suggests that the pregnancies with multiple chorionic bumps mostly result in fetal demise. Aims To review the available literature and the patients from our institute having sonographic findings of chorionic bump and making the sonographers and radiologists aware of this known cause of first-trimester pregnancy loss. Study design A retrospective review of the cases diagnosed at our institute during the last four years. Methods and materials Single-center institutional data for four years (January 2016-December 2019) was accessed using ICD codes. IRB approval was waived owing to the anonymized use of patient data. Results Six female patients diagnosed with chorionic bump were included, with a mean age of 29.83±12 years. The average gestational age at the time of diagnosis was 8.16±3 weeks. The most common sonographic findings were a protrusion from the chorionic wall into the gestational sac cavity, having a central hypoechoic region with peripheral hyperechoic rim (isoechoic to the chorion) and having no vascularity (n=5), and the less common finding was a hyperechoic protrusion with no vascularity (n=1). n=5 had a single lesion, and n=1 had two lesions. The average diameter of the lesion in the largest dimension was 18±11 mm. n=3 pregnancies resulted in a first-trimester miscarriage, and n=3 pregnancies delivered healthy babies at term.  Conclusions A chorionic bump significantly increases the risk of a first-trimester miscarriage.

6.
HardwareX ; 7: e00093, 2020 Apr.
Article in English | MEDLINE | ID: mdl-35495205

ABSTRACT

The potential of peripheral nerves to regenerate under the effect of axial tensile forces was not previously extensively explored due to the lack of capabilities of translating ex vivo axonal stretch-growth to in vivo studies, until the development of a nerve stretcher. The nerve stretcher, which we have designed and manufactured recently, is a device that uses a controlled amount of axial tensile force (vacuum/negative gauge pressure) applied directly to a sectioned peripheral nerve in vivo to expedite nerve regrowth rate. Using this platform, a series of experiments was carried out to observe the effect of in vivo axial stretch on axonal lengthening. During these experiments, a few challenges necessitated redesigning the device like a sudden loss of stretching force due to vacuum leakage, erroneous feedback from vacuum sensor due to sensor drift, and inability to control and operate the device remotely. Here we present an improved design of the nerve stretcher along with its integration with a state-of-the-art online vacuum monitoring facility to control, collect, process, and visualize negative gauge pressure data in real-time.

7.
Neural Regen Res ; 14(7): 1109-1115, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30804232

ABSTRACT

Peripheral nerve injuries are relatively common and can be caused by a variety of traumatic events such as motor vehicle accidents. They can lead to long-term disability, pain, and financial burden, and contribute to poor quality of life. In this review, we systematically analyze the contemporary literature on peripheral nerve gap management using nerve prostheses in conjunction with physical therapeutic agents. The use of nerve prostheses to assist nerve regeneration across large gaps (> 30 mm) has revolutionized neural surgery. The materials used for nerve prostheses have been greatly refined, making them suitable for repairing large nerve gaps. However, research on peripheral nerve gap management using nerve prostheses reports inconsistent functional outcomes, especially when prostheses are integrated with physical therapeutic agents, and thus warrants careful investigation. This review explores the effectiveness of nerve prostheses for bridging large nerve gaps and then addresses their use in combination with physical therapeutic agents.

SELECTION OF CITATIONS
SEARCH DETAIL
...