Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Am Soc Mass Spectrom ; 17(2): 168-79, 2006 Feb.
Article in English | MEDLINE | ID: mdl-16406561

ABSTRACT

Combining source collision-induced dissociation (CID) and tandem mass spectral acquisition in a pseudo-MS(3) experiment using a linear ion trap results in a highly selective and sensitive approach to identifying glycopeptide elution from a protein digest. The increased sensitivity is partially attributed to the nonselective nature of source CID, which allows simultaneous activation of all charge states and coeluting glycoforms generating greater ion abundance for the mass-to-charge (m/z) 204 and/or 366 oxonium ions. Unlike source CID alone, a pseudo-MS(3) approach adds selectivity while improving sensitivity by eliminating chemical noise during the tandem mass spectral acquisition of the oxonium ions in the linear ion trap. Performing the experiments in the hybrid linear ion trap/Fourier transform-ion cyclotron resonance (FT-ICR) enables subsequent high-resolution/high-mass accuracy full-scan mass spectra (MS) and parallel acquisition of MS/MS in the linear ion trap to be completed in 2 s directly following the pseudo-MS(3) scan to collate identification and characterization of glycopeptides in one experimental scan cycle. Analysis of bovine fetuin digest using the combined pseudo-MS(3), high-resolution MS, and data-dependent MS/MS events resulted in identification of four N-linked and two O-linked glycopeptides without enzymatic cleavage of the sugar moiety or release of the sialic acids before analysis. In addition, over 95% of the total protein sequence was identified in one analytical run.


Subject(s)
Glycoproteins/chemistry , Amino Acid Sequence , Animals , Carbohydrate Sequence , Cattle , Chromatography, High Pressure Liquid , Indicators and Reagents , Mass Spectrometry , Molecular Sequence Data , Oligosaccharides/chemistry , Spectroscopy, Fourier Transform Infrared , alpha-Fetoproteins/chemistry
2.
Anal Chem ; 74(2): 402-12, 2002 Jan 15.
Article in English | MEDLINE | ID: mdl-11811415

ABSTRACT

In the quadrupole ion trap, it has been noted that factors other than an ion's mass and charge may affect its measured m/z, resulting in compound-dependent, or "chemical", mass shifts. We propose that ions can exhibit a chemical mass shift because they are "fragile" and may fragment during the application of resonance ejection during mass analysis; these effects were studied using ions that include protonated, deprotonated, and adduct ions of explosives, acylcarnitines, and macrolide antibiotics. Fragile ions affect mass resolution by causing broader peaks than nonfragile ions, especially at slower scan speeds, as the result of the application of resonance ejection. Fragile ions may also be fragmented by the application of the isolation waveform during selection of the parent ion for tandem mass spectrometry experiments, making it impossible to achieve unit isolation of a fragile ion. To obtain adequate isolation intensity, the isolation waveform notch width must be increased and the time period of isolation must be decreased. Fragile ions also require lower optimum collision energy to achieve efficient collision-induced dissociation. We have developed criteria for the determination of the degree of ion fragility based upon experimental results.


Subject(s)
Anti-Bacterial Agents/analysis , Ions/pharmacology , Macrolides , Mass Spectrometry/instrumentation , Mass Spectrometry/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...