Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 22(11)2022 Jun 06.
Article in English | MEDLINE | ID: mdl-35684929

ABSTRACT

Recent backscattering interferometry studies utilise a single channel microfluidic system, typically approximately semicircular in cross-section. Here, we present a complete ray tracing model for on-chip backscattering interferometry with a semicircular cross-section, including the dependence upon polarisation and angle of incidence. The full model is validated and utilised to calculate the expected fringe patterns and sensitivities observed under both normal and oblique angles of incidence. Comparison with experimental data from approximately semicircular channels using the parameters stated shows that they cannot be explained using a semicircular geometry. The disagreement does not impact on the validity of the experimental data, but highlights that the optical mechanisms behind the various modalities of backscattering interferometry would benefit from clarification. From the analysis presented here, we conclude that for reasons of ease of analysis, data quality, and sensitivity for a given radius, capillary-based backscattering interferometry affords numerous benefits over on-chip backscattering interferometry.


Subject(s)
Interferometry , Microfluidics
2.
Phys Chem Chem Phys ; 24(21): 13040-13048, 2022 Jun 01.
Article in English | MEDLINE | ID: mdl-35583236

ABSTRACT

Control over nanorod dimensions is critical to their application, requiring fast, robust characterisation of their volume and aspect ratio whilst in their working medium. Here, we present an extension of Nanoparticle Tracking Analysis which determines the aspect ratio of nanoparticles from the polarisation state of scattered light in addition to a hydrodynamic diameter from Brownian motion. These data, in principle, permit the determination of nanorod dimensions of any composition using Nanoparticle Tracking Analysis. The results are compared with transmission electron microscopy and show that this technique can additionally determine the aggregation state of the nanorod dispersion if single nanorod dimensions are determined with a complementary technique. We also show it is possible to differentiate nanoparticles of similar hydrodynamic diameter by their depolarised scattering. Finally, we assess the ability of the technique to output nanorod dimensions and suggest ways to further improve the approach. This technique will enable rapid characterisation of nanorods in suspension, which are important tools for nanotechnology.

3.
Nanoscale ; 14(22): 8145-8152, 2022 Jun 09.
Article in English | MEDLINE | ID: mdl-35616244

ABSTRACT

Direct measurements to determine the degree of surface coverage of nanoparticles by functional moieties are rare, with current strategies requiring a high level of expertise and expensive equipment. Here, a practical method to determine the ratio of the volume of the functionalisation layer to the particle volume based on measuring the refractive index of nanoparticles in suspension is proposed. As a proof of concept, this technique is applied to poly(methyl methacrylate) (PMMA) nanoparticles and semicrystalline carbon dots functionalised with different surface moieties, yielding refractive indices that are commensurate to those from previous literature and Mie theory. In doing so, it is demonstrated that this technique is able to optically detect differences in surface functionalisation or composition of nanometre-sized particles. This non-destructive and rapid method is well-suited for in situ industrial particle characterisation and biological applications.

4.
Sensors (Basel) ; 22(6)2022 Mar 10.
Article in English | MEDLINE | ID: mdl-35336326

ABSTRACT

Capillary-based backscattering interferometry has been used extensively as a tool to measure molecular binding via interferometric refractive index sensing. Previous studies have analysed the fringe patterns created in the backscatter direction. However, polarisation effects, spatial chirps in the fringe pattern and the practical impact of various approximations, and assumptions in existing models are yet to be fully explored. Here, two independent ray tracing approaches are applied, analysed, contrasted, compared to experimental data, and improved upon by introducing explicit polarisation dependence. In doing so, the significance of the inner diameter, outer diameter, and material of the capillary to the resulting fringe pattern and subsequent analysis are elucidated for the first time. The inner diameter is shown to dictate the fringe pattern seen, and therefore, the effectiveness of any dechirping algorithm, demonstrating that current dechirping methods are only valid for a subset of capillary dimensions. Potential improvements are suggested in order to guide further research, increase sensitivity, and promote wider applicability.


Subject(s)
Interferometry , Refractometry , Algorithms , Interferometry/methods , Refractometry/methods
5.
Nanoscale Adv ; 3(19): 5694-5702, 2021 Sep 28.
Article in English | MEDLINE | ID: mdl-34604699

ABSTRACT

This work discusses the effects of increasing laser power on the size data derived from NTA for particles of known size and scatterers in solutions of flufenamic acid in ethanol. We find that whilst a higher laser power reveals more particles as expected, their residence time changes due to laser-induced convection. This reduced residence time decreases the number of tracks available for individual particle size determination, shifting the size distribution to smaller values. This problem is overcome by using a shutter to inhibit the development of convection currents, increasing particle residence time and reducing the error on the size distribution. The detailed understanding of laser-induced convection permits more robust size characterisation of mesoscopic organic clusters, which play a key role in two-step nucleation theory.

SELECTION OF CITATIONS
SEARCH DETAIL
...