Muscle Nerve ; 56(3): 458-462, 2017 09.
Article in English | MEDLINE | ID: mdl-28029686

ABSTRACT

INTRODUCTION: There are many different nerve conduction study (NCS) techniques to study the superficial fibular sensory nerve (SFSN). We present reference distal latency values and comparative data regarding 4 different NCS for the SFSN. METHODS: Four different NCS techniques, Spartan technique, Izzo techniques (medial and intermediate dorsal cutaneous branches), and Daube technique, were performed on (114) healthy volunteers. A total of 108 subjects with 164 legs were included. RESULTS: The mean latency of the Spartan technique was longest (3.9 ± 0.3 ms) while the Daube technique was the shortest (3.6 ± 0.7 ms). The mean amplitude of the Daube technique displayed the highest (15.2 ± 8.2 µV) with the Spartan technique having the lowest (8.7 ± 4.2 µV). Among the absent sensory nerve action potentials (SNAPs), the Spartan technique was absent only twice (1.2%) and the Izzo Medial technique was absent more than the other techniques (2.9%). CONCLUSIONS: All 4 techniques were reliable methods for obtaining the superficial fibular nerve SNAP, present in 95% of individuals. Muscle Nerve 56: 458-462, 2017.


Subject(s)
Electrodiagnosis/methods , Neural Conduction/physiology , Peroneal Nerve/physiology , Sensory Receptor Cells/physiology , Action Potentials/physiology , Adult , Aged , Electrodiagnosis/instrumentation , Electrodiagnosis/standards , Female , Humans , Male , Middle Aged , Young Adult