Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Microsc Microanal ; 21(4): 1017-1025, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26223550

ABSTRACT

We describe a system for rapidly screening hundreds of nanoparticle samples using transmission electron microscopy (TEM). The system uses a liquid handling robot to place up to 96 individual samples onto a single standard TEM grid at separate locations. The grid is then transferred into the TEM and automated software is used to acquire multiscale images of each sample. The images are then analyzed to extract metrics on the size, shape, and morphology of the nanoparticles. The system has been used to characterize plasmonically active nanomaterials.


Subject(s)
High-Throughput Screening Assays/methods , Microscopy, Electron, Transmission/methods , Nanoparticles/analysis , Robotics/methods , Specimen Handling/methods
2.
J Pharm Sci ; 104(2): 750-9, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25231267

ABSTRACT

Aggregation of protein-based therapeutics is a challenging problem in the biopharmaceutical industry. Of particular concern are implications for product efficacy and clinical safety because of potentially increased immunogenicity of the aggregates. We used transmission electron microscopy (TEM) to characterize biophysical and morphological features of antibody aggregates formed upon controlled environmental stresses. TEM results were contrasted with results obtained in parallel by independent methods, including size-exclusion chromatography, dynamic light scattering, microflow imaging, and nanoparticle tracking. For TEM, stressed samples were imaged by negative staining and in the frozen-hydrated state. In both cases, aggregates appeared amorphous but differed in fine structural detail. Specifically, negatively stained aggregates were compact and consisted of smaller globular structures that had a notable three-dimensional character. Elements of the native IgG structure were retained, suggesting that the aggregates were not assembled from denatured protein. In contrast, aggregates in frozen-hydrated samples appeared as extended, branched protein networks with large surface area. Using multiple scales of magnification, a wide range of particle sizes was observed and semiquantitatively characterized. The detailed information provided by TEM extended observations obtained with the independent methods, demonstrating the suitability of TEM as a complementary approach to submicron particle analysis.


Subject(s)
Immunoglobulins, Intravenous/chemistry , Immunoglobulins, Intravenous/ultrastructure , Microscopy, Electron, Transmission/methods , Protein Aggregates , Particle Size , Protein Aggregates/physiology
3.
Int J Nanomedicine ; 9: 1367-77, 2014.
Article in English | MEDLINE | ID: mdl-24648734

ABSTRACT

Development of lipid-based adjuvant formulations to enhance the immunogenicity of recombinant vaccine antigens is a focus of modern vaccine research. Characterizing interactions between vaccine antigens and formulation excipients is important for establishing compatibility between the different components and optimizing vaccine stability and potency. Cryogenic transmission electron microscopy (TEM) is a highly informative analytical technique that may elucidate various aspects of protein- and lipid-based structures, including morphology, size, shape, and phase structure, while avoiding artifacts associated with staining-based TEM. In this work, cryogenic TEM is employed to characterize a recombinant tuberculosis vaccine antigen, an anionic liposome formulation, and antigen-liposome interactions. By performing three-dimensional tomographic reconstruction analysis, the formation of a population of protein-containing flattened liposomes, not present in the control samples, was detected. It is shown that cryogenic TEM provides unique information regarding antigen-liposome interactions not detectable by light-scattering-based methods. Employing a suite of complementary analytical techniques is important to fully characterize interactions between vaccine components.


Subject(s)
Antigens, Bacterial/chemistry , Tuberculosis Vaccines/immunology , Adjuvants, Immunologic/administration & dosage , Animals , Antigens, Bacterial/ultrastructure , Cryoelectron Microscopy , Humans , Imaging, Three-Dimensional , Liposomes/administration & dosage , Liposomes/chemistry , Nanomedicine , Nanoparticles/administration & dosage , Nanoparticles/chemistry , Particle Size , Tuberculosis Vaccines/administration & dosage , Tuberculosis Vaccines/chemistry , Vaccines, Synthetic/administration & dosage , Vaccines, Synthetic/chemistry , Vaccines, Synthetic/immunology
SELECTION OF CITATIONS
SEARCH DETAIL
...