Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 58
Filter
1.
JACC Cardiovasc Interv ; 17(8): 979-988, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38658126

ABSTRACT

BACKGROUND: Symptomatic patients with severe aortic stenosis (AS) at high risk for surgical aortic valve replacement (SAVR) sustain comparable improvements in health status over 5 years after transcatheter aortic valve replacement (TAVR) or SAVR. Whether a similar long-term benefit is observed among intermediate-risk AS patients is unknown. OBJECTIVES: The purpose of this study was to assess health status outcomes through 5 years in intermediate risk patients treated with a self-expanding TAVR prosthesis or SAVR using data from the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial. METHODS: Intermediate-risk patients randomized to transfemoral TAVR or SAVR in the SURTAVI trial had disease-specific health status assessed at baseline, 30 days, and annually to 5 years using the Kansas City Cardiomyopathy Questionnaire (KCCQ). Health status was compared between groups using fixed effects repeated measures modelling. RESULTS: Of the 1,584 patients (TAVR, n = 805; SAVR, n = 779) included in the analysis, health status improved more rapidly after TAVR compared with SAVR. However, by 1 year, both groups experienced large health status benefits (mean change in KCCQ-Overall Summary Score (KCCQ-OS) from baseline: TAVR: 20.5 ± 22.4; SAVR: 20.5 ± 22.2). This benefit was sustained, albeit modestly attenuated, at 5 years (mean change in KCCQ-OS from baseline: TAVR: 15.4 ± 25.1; SAVR: 14.3 ± 24.2). There were no significant differences in health status between the cohorts at 1 year or beyond. Similar findings were observed in the KCCQ subscales, although a substantial attenuation of benefit was noted in the physical limitation subscale over time in both groups. CONCLUSIONS: In intermediate-risk AS patients, both transfemoral TAVR and SAVR resulted in comparable and durable health status benefits to 5 years. Further research is necessary to elucidate the mechanisms for the small decline in health status noted at 5 years compared with 1 year in both groups. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910).


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Femoral Artery , Health Status , Heart Valve Prosthesis , Quality of Life , Recovery of Function , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Female , Male , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Aged , Aged, 80 and over , Risk Factors , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Risk Assessment , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Catheterization, Peripheral/adverse effects , Punctures , Prosthesis Design
2.
JTCVS Open ; 17: 55-63, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38420551

ABSTRACT

Background: The use of rapid-deployment valves (RDVs) has been shown to reduce the operative time for surgical aortic valve replacement (AVR). Long-term core laboratory-adjudicated data are scarce, however. Here we report final 7-year data on RDV use. Methods: TRANSFORM was a prospective, nonrandomized, multicenter, single-arm trial implanting a stented bovine pericardial valve with an incorporated balloon-expandable sealing frame. A prior published 1-year analysis included 839 patients from 29 centers. An additional 46 patients were enrolled and implanted, for a total of 885 patients. Annual clinical and core laboratory-adjudicated echocardiographic outcomes were collected through 8 years. Primary endpoints were structural valve deterioration (SVD), all-cause reintervention, all-cause valve explantation, and all-cause mortality. Secondary endpoints included hemodynamic performance assessed by echocardiography. The mean duration of follow-up was 5.0 ± 2.0 years. Results: The mean patient age was 73.3 ± 8.2 years. Isolated AVR was performed in 62.1% of the patients, and AVR with concomitant procedures was performed in 37.9%. Freedom from all-cause mortality at 7 years was 76.0% for isolated AVR and 68.2% for concomitant AVR. Freedom from SVD, all-cause reintervention, and valve explantation at 7 years was 97.5%, 95.7%, and 97.8%, respectively. The mean gradient and effective orifice area at 7 years were 11.1 ± 5.3 mm Hg and 1.6 ± 0.3 cm2, respectively. Paravalvular leak at 7 years was none/trace in 88.6% and mild in 11.4%. In patients undergoing isolated AVR, the cumulative probability of pacemaker implantation was 13.9% at 30 days, 15.5% at 1 year, and 21.8% at 7 years. Conclusions: AVR for aortic stenosis using an RDV is associated with low rates of late adverse events. This surgical pericardial tissue platform provides excellent and stable hemodynamic performance through 7 years.

3.
Ann Thorac Surg ; 2023 Dec 21.
Article in English | MEDLINE | ID: mdl-38135262

ABSTRACT

BACKGROUND: This study investigated the safety and effectiveness of surgical aortic valve replacement with RESILIA tissue (Edwards Lifesciences) through 5 years in patients with native bicuspid aortic valves. Outcomes were compared with those for patients with tricuspid aortic valves. METHODS: Of 689 patients from the COMMENCE (ProspeCtive, nOn-randoMized, MulticENter) trial who received the study valve, 645 had documented native valve morphology and core laboratory-evaluable echocardiograms from any postoperative visit, which were used to model hemodynamic outcomes over 5 years. Linear mixed-effects models were used to estimate longitudinal changes in mean gradient and effective orifice area. RESULTS: Patients with native bicuspid aortic valves (n = 214) were more than a decade younger than those with tricuspid aortic valves (n = 458; 59.8 ± 12.4 years vs 70.2 ± 9.5 years; P < .001). The bicuspid aortic valve cohort exhibited no structural valve deterioration over 5 years, and rates of paravalvular leak and transvalvular regurgitation were low (0.7% and 2.9%, respectively [all mild] at 5 years). These outcomes mirrored those in patients with native tricuspid aortic valves. The model-estimated postoperative mean gradient and effective orifice area, as well as the rate of change of these outcomes, adjusted for age, body surface area, and bioprosthesis size, did not differ between the 2 cohorts. CONCLUSIONS: Among patients with bicuspid aortic valves, RESILIA tissue valves demonstrated excellent outcomes to 5 years, including no structural valve deterioration and very low rates of paravalvular and transvalvular regurgitation. These results are encouraging for RESILIA tissue durability in young patients.

4.
Article in English | MEDLINE | ID: mdl-37962288

ABSTRACT

BACKGROUND: The CLASP IID (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical) trial is the first randomized controlled trial comparing the PASCAL system and the MitraClip system in prohibitive risk patients with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: The study sought to report primary and secondary endpoints and 1-year outcomes for the full cohort of the CLASP IID trial. METHODS: Prohibitive-risk patients with 3+/4+ DMR were randomized 2:1 (PASCAL:MitraClip). One-year assessments included secondary effectiveness endpoints (mitral regurgitation [MR] ≤2+ and MR ≤1+), and clinical, echocardiographic, functional, and quality-of-life outcomes. Primary safety (30-day composite major adverse events [MAE]) and effectiveness (6-month MR ≤2+) endpoints were assessed for the full cohort. RESULTS: Three hundred patients were randomized (PASCAL: n = 204; MitraClip: n = 96). At 1 year, differences in survival, freedom from heart failure hospitalization, and MAE were nonsignificant (P > 0.05 for all). Noninferiority of the PASCAL system compared with the MitraClip system persisted for the primary endpoints in the full cohort (For PASCAL vs MitraClip, the 30-day MAE rates were 4.6% vs 5.4% with a rate difference of -0.8% and 95% upper confidence bound of 4.6%. The 6-month MR≤2+ rates were 97.9% vs 95.7% with a rate difference of 2.2% and 95% lower confidence bound (LCB) of -2.5%, for, respectively). Noninferiority was met for the secondary effectiveness endpoints at 1 year (MR≤2+ rates for PASCAL vs MitraClip were 95.8% vs 93.8% with a rate difference of 2.1% and 95% LCB of -4.1%. The MR≤1+ rates were 77.1% vs 71.3% with a rate difference of 5.8% and 95% LCB of -5.3%, respectively). Significant improvements in functional classification and quality of life were sustained in both groups (P <0.05 for all vs baseline). CONCLUSIONS: The CLASP IID trial full cohort met primary and secondary noninferiority endpoints, and at 1 year, the PASCAL system demonstrated high survival, significant MR reduction, and sustained improvements in functional and quality-of-life outcomes. Results affirm the PASCAL system as a beneficial therapy for prohibitive-surgical-risk patients with significant symptomatic DMR.

5.
JACC Cardiovasc Interv ; 16(23): 2868-2879, 2023 Dec 11.
Article in English | MEDLINE | ID: mdl-37902145

ABSTRACT

BACKGROUND: High surgical risk may preclude mitral valve replacement in many patients. Transcatheter mitral valve replacement (TMVR) using transfemoral transseptal access is a novel technology for the treatment of mitral regurgitation (MR) in high-risk surgical patients. OBJECTIVES: This analysis evaluates 30-day and 1-year outcomes of the Intrepid TMVR Early Feasibility Study in patients with ≥moderate-severe MR. METHODS: The Intrepid TMVR Early Feasibility Study is a multicenter, prospective, single-arm study. Clinical events were adjudicated by a clinical events committee; endpoints were defined according to Mitral Valve Academic Research Consortium criteria. RESULTS: A total of 33 patients, enrolled at 9 U.S. sites between February 2020 and August 2022, were included. The median age was 80 years, 63.6% of patients were men, and mean Society of Thoracic Surgeons Predicted Risk of Mortality for mitral valve replacement was 5.3%. Thirty-one (93.9%) patients were successfully implanted. Median postprocedural hospitalization length of stay was 5 days, and 87.9% of patients were discharged to home. At 30 days, there were no deaths or strokes, 8 (24.2%) patients had major vascular complications and none required surgical intervention, there were 4 cases of venous thromboembolism all successfully treated without sequelae, and 1 patient had mitral valve reintervention for severe left ventricular outflow tract obstruction. At 1 year, the Kaplan-Meier all-cause mortality rate was 6.7%, echocardiography showed ≤mild valvular MR, there was no/trace paravalvular leak in all patients, median mitral valve mean gradient was 4.6 mm Hg (Q1-Q3: 3.9-5.3 mm Hg), and 91.7% of survivors were in NYHA functional class I/II with a median 11.4-point improvement in Kansas City Cardiomyopathy Questionnaire overall summary scores. CONCLUSIONS: The early benefits of the Intrepid transfemoral transseptal TMVR system were maintained up to 1 year with low mortality, low reintervention, and near complete elimination of MR, demonstrating a favorable safety profile and durable valve function.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Male , Humans , Aged, 80 and over , Female , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Feasibility Studies , Prospective Studies , Cardiac Catheterization/methods , Treatment Outcome , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology
6.
JTCVS Open ; 15: 151-163, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37808026

ABSTRACT

Objective: Novel tissue leaflets (RESILIA tissue) may improve durability of bioprosthetic heart valves. The COMMENCE trial is an ongoing prospective study to evaluate valve replacement using RESILIA tissue. This report describes mid-term outcomes in the mitral cohort of COMMENCE. Methods: Adult patients requiring mitral valve replacement were enrolled in a prospective, single-arm trial at 17 sites in the United States and Canada. An independent clinical events committee adjudicated safety events using definitions from established guidelines, and hemodynamic performance was evaluated by an independent echocardiographic core laboratory. Results: Eighty-two patients (median age 70 years) successfully underwent mitral valve replacement with the study valve. Five-year event-free probabilities for all-cause mortality, structural valve deterioration, and reoperation were 79.9%, 98.7%, and 97.1%, respectively. Hemodynamic valve function measurements were stable through the 5-year follow-up period; valvular leaks were infrequently observed and primarily clinically insignificant/mild. Conclusions: Mitral valve replacement patients implanted with a RESILIA tissue bioprosthesis had a good safety profile and clinically stable hemodynamic performance.

8.
JTCVS Open ; 14: 134-144, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37425449

ABSTRACT

Objective: A kaolin-based nonresorbable hemostatic gauze, QuikClot Control+, has demonstrated effective hemostasis and safety when used for severe/life-threatening (grade 3/4) internal organ space bleeding. We evaluated the efficacy and safety of this gauze for mild to moderate (grade 1-2) bleeding in cardiac surgery compared with control gauze. Methods: This was a randomized, controlled, single-blinded study of patients who underwent cardiac surgery between June 2020 and September 2021 across 7 sites with 231 subjects randomized 2:1 to QuikClot Control+ or control. The primary efficacy end point was hemostasis rate (ie, subjects achieving grade 0 bleed) through up to 10 minutes of bleeding site application, assessed using a semiquantitative validated bleeding severity scale tool. The secondary efficacy end point was the proportion of subjects achieving hemostasis at 5 and 10 minutes. Adverse events, assessed up to 30 days postsurgery, were compared between arms. Results: The predominant procedure was coronary artery bypass grafting, and 69.7% and 29.4% were sternal edge and surgical site (suture line)/other bleeds, respectively. Of the QuikClot Control+ subjects, 121 of 153 (79.1%) achieved hemostasis within 5 minutes, compared with 45 of 78 (58.4%) controls (P < .001). At 10 minutes, 137 of 153 patients (89.8%) achieved hemostasis compared with 52 of 78 controls (68.4%) (P < .001). At 5 and 10 minutes, hemostasis was achieved in 20.7% and 21.4% more QuikClot Control+ subjects, respectively, compared with controls (P < .001). There were no significant differences in safety or adverse events between treatment arms. Conclusions: QuikClot Control+ demonstrated superior performance in achieving hemostasis for mild to moderate cardiac surgery bleeding compared with control gauze. The proportion of subjects achieving hemostasis was more than 20% higher in QuikClot Control+ subjects at both timepoints compared with controls, with no significant difference in safety outcomes.

9.
Open Heart ; 10(1)2023 05.
Article in English | MEDLINE | ID: mdl-37173100

ABSTRACT

OBJECTIVE: To evaluate whether transcatheter or surgical aortic valve replacement (TAVR or SAVR) affects clinical and haemodynamic outcomes in symptomatic patients with moderately-severe aortic stenosis (AS). METHODS: Echocardiographic evidence of severe AS for enrolment in the Evolut Low Risk trial was based on site-reported measurements. For this post hoc analysis, core laboratory measurements identified patients with symptomatic moderately-severe AS (1.0

Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Quality of Life , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Treatment Outcome
10.
J Am Coll Cardiol ; 81(17): 1663-1674, 2023 05 02.
Article in English | MEDLINE | ID: mdl-36882136

ABSTRACT

BACKGROUND: Randomized data comparing outcomes of transcatheter aortic valve replacement (TAVR) with surgery in low-surgical risk patients at time points beyond 2 years is limited. This presents an unknown for physicians striving to educate patients as part of a shared decision-making process. OBJECTIVES: The authors evaluated 3-year clinical and echocardiographic outcomes from the Evolut Low Risk trial. METHODS: Low-risk patients were randomized to TAVR with a self-expanding, supra-annular valve or surgery. The primary endpoint of all-cause mortality or disabling stroke and several secondary endpoints were assessed at 3 years. RESULTS: There were 1,414 attempted implantations (730 TAVR; 684 surgery). Patients had a mean age of 74 years and 35% were women. At 3 years, the primary endpoint occurred in 7.4% of TAVR patients and 10.4% of surgery patients (HR: 0.70; 95% CI: 0.49-1.00; P = 0.051). The difference between treatment arms for all-cause mortality or disabling stroke remained broadly consistent over time: -1.8% at year 1; -2.0% at year 2; and -2.9% at year 3. The incidence of mild paravalvular regurgitation (20.3% TAVR vs 2.5% surgery) and pacemaker placement (23.2% TAVR vs 9.1% surgery; P < 0.001) were lower in the surgery group. Rates of moderate or greater paravalvular regurgitation for both groups were <1% and not significantly different. Patients who underwent TAVR had significantly improved valve hemodynamics (mean gradient 9.1 mm Hg TAVR vs 12.1 mm Hg surgery; P < 0.001) at 3 years. CONCLUSIONS: Within the Evolut Low Risk study, TAVR at 3 years showed durable benefits compared with surgery with respect to all-cause mortality or disabling stroke. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283).


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Male , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Risk Factors , Treatment Outcome , Prospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Heart Valve Prosthesis/adverse effects , Stroke/epidemiology , Stroke/etiology , Stroke/surgery
11.
Cardiovasc Revasc Med ; 47: 48-54, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36266154

ABSTRACT

We evaluated predictors of permanent pacemaker implantation (PPI) following self-expanding transcatheter aortic valve replacement (TAVR), examined site-to-site variability of PPI rates, and explored the relationship of implantation methods on the need for PPI. Despite the benefits of TAVR compared to surgical aortic valve replacement, increased PPI remains a limitation. A total of 699 patients without baseline PPI were included in the study. Clinical, echocardiographic, and procedural characteristics were compared in patient with and without new PPI. Clinical outcomes were assessed at 30 days and 1 year. Funnel plots were constructed to display site-to- site variability and identify outliers in PPI. Clinical outcomes were similar in patients with and without PPI. Predictors of a new PPI within 7 days included a baseline right bundle branch block (p < 0.001) and not using general anesthesia (p = 0.003). There was substantial site to site variability in the rate of PPI. Patients at sites with a lower PPI rate had shallower implantation depth at the non-coronary (p < 0.001) and the left coronary sinus (p < 0.001), and fewer patients with an implantation depth > 5 mm below the annulus (p = 0.004). In low-risk patients undergoing TAVR with Evolut valves, baseline conduction disorders and implant depth were important predictors of PPI. Implantation method may have contributed to this variability in PPI rates across clinical sites.


Subject(s)
Aortic Valve Stenosis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis , Pacemaker, Artificial/statistics & numerical data , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
12.
JAMA Cardiol ; 8(2): 111-119, 2023 02 01.
Article in English | MEDLINE | ID: mdl-36515976

ABSTRACT

Importance: The frequency and clinical importance of structural valve deterioration (SVD) in patients undergoing self-expanding transcatheter aortic valve implantation (TAVI) or surgery is poorly understood. Objective: To evaluate the 5-year incidence, clinical outcomes, and predictors of hemodynamic SVD in patients undergoing self-expanding TAVI or surgery. Design, Setting, and Participants: This post hoc analysis pooled data from the CoreValve US High Risk Pivotal (n = 615) and SURTAVI (n = 1484) randomized clinical trials (RCTs); it was supplemented by the CoreValve Extreme Risk Pivotal trial (n = 485) and CoreValve Continued Access Study (n = 2178). Patients with severe aortic valve stenosis deemed to be at intermediate or increased risk of 30-day surgical mortality were included. Data were collected from December 2010 to June 2016, and data were analyzed from December 2021 to October 2022. Interventions: Patients were randomized to self-expanding TAVI or surgery in the RCTs or underwent self-expanding TAVI for clinical indications in the nonrandomized studies. Main Outcomes and Measures: The primary end point was the incidence of SVD through 5 years (from the RCTs). Factors associated with SVD and its association with clinical outcomes were evaluated for the pooled RCT and non-RCT population. SVD was defined as (1) an increase in mean gradient of 10 mm Hg or greater from discharge or at 30 days to last echocardiography with a final mean gradient of 20 mm Hg or greater or (2) new-onset moderate or severe intraprosthetic aortic regurgitation or an increase of 1 grade or more. Results: Of 4762 included patients, 2605 (54.7%) were male, and the mean (SD) age was 82.1 (7.4) years. A total of 2099 RCT patients, including 1128 who received TAVI and 971 who received surgery, and 2663 non-RCT patients who received TAVI were included. The cumulative incidence of SVD treating death as a competing risk was lower in patients undergoing TAVI than surgery (TAVI, 2.20%; surgery, 4.38%; hazard ratio [HR], 0.46; 95% CI, 0.27-0.78; P = .004). This lower risk was most pronounced in patients with smaller annuli (23 mm diameter or smaller; TAVI, 1.32%; surgery, 5.84%; HR, 0.21; 95% CI, 0.06-0.73; P = .02). SVD was associated with increased 5-year all-cause mortality (HR, 2.03; 95% CI, 1.46-2.82; P < .001), cardiovascular mortality (HR, 1.86; 95% CI, 1.20-2.90; P = .006), and valve disease or worsening heart failure hospitalizations (HR, 2.17; 95% CI, 1.23-3.84; P = .008). Predictors of SVD were developed from multivariate analysis. Conclusions and Relevance: This study found a lower rate of SVD in patients undergoing self-expanding TAVI vs surgery at 5 years. Doppler echocardiography was a valuable tool to detect SVD, which was associated with worse clinical outcomes. Trial Registration: ClinicalTrials.gov Identifiers: NCT01240902, NCT01586910, and NCT01531374.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Male , Humans , Aged, 80 and over , Female , Aortic Valve/surgery , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects
13.
Ann Thorac Surg ; 115(6): 1429-1436, 2023 06.
Article in English | MEDLINE | ID: mdl-35065065

ABSTRACT

BACKGROUND: The COMMENCE trial was conducted to evaluate the safety and effectiveness of aortic valve replacement using a bioprosthesis with novel RESILIA tissue (Edwards Lifesciences). RESILIA tissue is incorporated in the INSPIRIS RESILIA aortic valve (Edwards Lifesciences). METHODS: Patients underwent clinically indicated surgical aortic valve replacement with a bovine pericardial bioprosthesis (model 11000A; Edwards Lifesciences) in a prospective, multinational, multicenter (n = 27), US Food and Drug Administration Investigational Device Exemption trial. Events were adjudicated by an independent clinical events committee, and echocardiograms were analyzed by an independent core laboratory. Outcomes through an observational period of 5 years are reported. RESULTS: Between January 2013 and March 2016, 689 patients received the study valve. Mean patient age was 66.9 ± 11.6 years; Society of Thoracic Surgeons Predicted Risk of Mortality was 2.0% ± 1.8%; and 23.8%, 49.9%, and 24.4% of patients were New York Heart Association functional class I, II, and III at baseline, respectively. Through December 11, 2020 the follow-up duration was 4.3 ± 1.4 years, and the completeness of follow-up over the observational period was 95.5%. Early (<30 days) all-cause mortality was 1.2%, stroke 1.6%, and major paravalvular leak 0.1%. Five-year actuarial freedom from all-cause mortality, structural valve deterioration, and all-cause reintervention were 89.2%, 100%, and 98.7%, respectively. At 5 years the effective orifice area was 1.6 ± 0.5 cm2, mean gradient was 11.5 ± 6.0 mm Hg, 97.8% of patients were class I/II, and 97.8% and 96.3% of patients had none/trace paravalvular and transvalvular regurgitation, respectively. CONCLUSIONS: The safety and hemodynamic performance of this aortic bioprosthesis with RESILIA tissue through 5 years are encouraging, with clinically stable hemodynamics, minimal regurgitation, and no evidence of structural valve deterioration.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Humans , Animals , Cattle , Middle Aged , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Prospective Studies , Treatment Outcome
14.
Innovations (Phila) ; 17(6): 463-470, 2022.
Article in English | MEDLINE | ID: mdl-36373654

ABSTRACT

OBJECTIVE: Patients with elevated CHA2DS2-VASc scores are at high risk for atrial fibrillation (AF) and thromboembolic events (TE) after cardiac surgery. Left atrial appendage exclusion (LAAE) is a permanent, continuous approach to stroke prevention in AF, overcoming limitations of oral anticoagulation (OAC). We report ATLAS trial results focused on LAAE technical success and perioperative safety and TE rates with and without LAAE in cardiac surgery patients who developed postoperative AF (POAF). METHODS: ATLAS (NCT02701062) was a prospective, multicenter, feasibility trial. Patients age ≥18 years, undergoing structural heart procedure, with no preoperative AF, CHA2DS2-VASc ≥2, and HAS-BLED ≥2 were randomized 2:1 to LAAE or no LAAE. Patients who developed POAF and/or received LAAE were followed for 1 year. LAAE was evaluated with intraoperative transesophageal echocardiography. RESULTS: A total of 562 patients were randomized to LAAE (n = 376) or no LAAE (n = 186). Mean CHA2DS2-VASc (3.4 vs 3.4) and HAS-BLED (2.8 vs 2.9) scores were similar for LAAE and no LAAE groups. LAAE success (no flow nor residual stump >10 mm) was 99%. One LAAE-related serious adverse event (0.27%) occurred and was resolved without sequelae. There were 44.3% of patients who developed POAF. Through 1 year, 3.4% of LAAE patients and 5.6% of no LAAE patients had TE. OAC was used by 32.5% of POAF patients. Bleeding was higher with OAC than without (16.1% vs 5.4%, P = 0.008). CONCLUSIONS: ATLAS demonstrated a high rate of successful LAAE with low LAAE-related serious adverse events in cardiac surgery patients. Study results should be considered in future trial design to further evaluate prophylactic LAAE for stroke prevention in cardiac surgery patients with elevated stroke risk.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiac Surgical Procedures , Stroke , Humans , Adolescent , Risk Factors , Risk Assessment/methods , Atrial Appendage/surgery , Prospective Studies , Cardiac Surgical Procedures/adverse effects , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , Hemorrhage/complications , Atrial Fibrillation/surgery
15.
JACC Cardiovasc Interv ; 15(24): 2523-2536, 2022 12 26.
Article in English | MEDLINE | ID: mdl-36121247

ABSTRACT

BACKGROUND: Severe symptomatic degenerative mitral regurgitation (DMR) has a poor prognosis in the absence of treatment, and new transcatheter options are emerging. OBJECTIVES: The CLASP IID (Edwards PASCAL Transcatheter Valve Repair System Pivotal Clinical Trial) randomized trial (NCT03706833) is the first to evaluate the safety and effectiveness of the PASCAL system compared with the MitraClip system in patients with significant symptomatic DMR. This report presents the primary safety and effectiveness endpoints for the trial. METHODS: Patients with 3+ or 4+ DMR at prohibitive surgical risk were assessed by a central screening committee and randomized 2:1 (PASCAL:MitraClip). Study oversight also included an echocardiography core laboratory and a clinical events committee. The primary safety endpoint was the composite major adverse event rate at 30 days. The primary effectiveness endpoint was the proportion of patients with mitral regurgitation (MR) ≤2+ at 6 months. RESULTS: A prespecified interim analysis in 180 patients demonstrated noninferiority of the PASCAL system vs the MitraClip system for the primary safety and effectiveness endpoints of major adverse event rate (3.4% vs 4.8%) and MR ≤2+ (96.5% vs 96.8%), respectively. Functional and quality-of-life outcomes significantly improved in both groups (P < 0.05). The proportion of patients with MR ≤1+ was durable in the PASCAL group from discharge to 6 months (PASCAL, 87.2% and 83.7% [P = 0.317 vs discharge]; MitraClip, 88.5% and 71.2% [P = 0.003 vs discharge]). CONCLUSIONS: The CLASP IID trial demonstrated safety and effectiveness of the PASCAL system and met noninferiority endpoints, expanding transcatheter treatment options for prohibitive surgical risk patients with significant symptomatic DMR.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Cardiac Catheterization/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Quality of Life , Treatment Outcome
16.
JAMA Cardiol ; 7(10): 1000-1008, 2022 10 01.
Article in English | MEDLINE | ID: mdl-36001335

ABSTRACT

Importance: In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective: To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants: SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention: Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures: The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results: A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm2 vs 1.8 [0.6] cm2; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance: Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Aged , Aortic Valve/surgery , Aortic Valve Stenosis/complications , Female , Heart Valve Prosthesis/adverse effects , Humans , Male , Prospective Studies , Stroke/epidemiology , Stroke/etiology
18.
Ann Thorac Surg ; 114(4): 1108-1117, 2022 10.
Article in English | MEDLINE | ID: mdl-35439450

ABSTRACT

BACKGROUND: Aortic valve replacement is the traditional surgical treatment for aortic valve diseases, yet standardized aortic valve neocuspidization (AVNeo) is a promising alternative that is gaining popularity. The purpose of this article is to review the available published literature of AVNeo using glutaraldehyde-treated autologous pericardium, also known as the Ozaki procedure, including indications, outcomes, potential benefits, and modes of failure for the reconstructed valve. METHODS: A comprehensive literature search was performed using keywords related to aortic valve repair, AVNeo, or Ozaki procedure. All articles describing performance of AVNeo were reviewed. RESULTS: Reported early mortality after AVNeo varies from 0% to 5.88%. The largest cohort of patients in the literature includes 850 patients with an inhospital mortality rate of 1.88%. Cumulative incidence of aortic valve reoperation was 4.2% in the largest series. Reoperation was uncommon and mainly due to infective endocarditis or degeneration of the reconstructed valve (most commonly due to aortic valve regurgitation, rather than stenosis). CONCLUSIONS: Aortic valve neocuspidization is a versatile and standardized alternative to aortic valve replacement with a biological prosthesis. Early to midterm outcomes from a number of centers are excellent and demonstrate the safety and durability of the procedure. Long-term outcomes and clinical trial data are necessary to determine which patients benefit the most from this procedure.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Glutaral , Humans , Pericardium/transplantation , Reoperation , Treatment Outcome
19.
JACC Cardiovasc Interv ; 15(5): 511-522, 2022 03 14.
Article in English | MEDLINE | ID: mdl-35272776

ABSTRACT

OBJECTIVES: The aim of this study was to compare 1-year outcomes after transcatheter aortic valve replacement (TAVR) in low surgical risk patients with bicuspid aortic stenosis to patients with tricuspid aortic stenosis. BACKGROUND: The pivotal TAVR trials excluded patients with bicuspid aortic valves. The Low Risk Bicuspid Study 30-day primary endpoint of death or disabling stroke was 1.3%. METHODS: The Low Risk Bicuspid Study is a prospective, single-arm, TAVR trial that enrolled patients from 25 U.S. sites. A screening committee confirmed bicuspid anatomy and valve classification on computed tomography using the Sievers classification. Valve sizing was by annular measurements. An independent clinical events committee adjudicated all serious adverse events, and an independent core laboratory assessed all echocardiograms. The 150 patients from the Low Risk Bicuspid Study were propensity matched to the TAVR patients in the randomized Evolut Low Risk Trial using the 1:1 5- to-1-digit greedy method, resulting in 145 pairs. RESULTS: All-cause mortality or disabling stroke at 1 year was 1.4% in the bicuspid and 2.8% in the tricuspid group (P = 0.413). A pacemaker was implanted in 16.6% of bicuspid and 17.9% of tricuspid patients (P = 0.741). The effective orifice area was similar between groups at 1 year (2.2 ± 0.7 cm2 vs 2.3 ± 0.6 cm2, P = 0.677) as was the mean gradient (8.7 ± 3.9 mm Hg vs 8.5 ± 3.1 mm Hg, P = 0.754). Fewer patients in the bicuspid group had mild or worse paravalvular leak (21.3% vs 42.6%, P < 0.001). CONCLUSIONS: There were no significant differences in clinical or forward flow hemodynamic outcomes between the propensity-matched groups at 1 year.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Humans , Prospective Studies , Risk , Treatment Outcome
20.
J Am Coll Cardiol ; 79(9): 882-896, 2022 03 08.
Article in English | MEDLINE | ID: mdl-35241222

ABSTRACT

BACKGROUND: The Evolut Low Risk Trial (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients) showed that transcatheter aortic valve replacement (TAVR) with a supra-annular, self-expanding valve was noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke at 2 years. This finding was based on a Bayesian analysis performed after 850 patients had reached 1 year of follow-up. OBJECTIVES: The goal of this study was to report the full 2-year clinical and echocardiographic outcomes for patients enrolled in the Evolut Low Risk Trial. METHODS: A total of 1,414 low-surgical risk patients with severe aortic stenosis were randomized to receive TAVR or surgical AVR. An independent clinical events committee adjudicated adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints. RESULTS: An attempted implant was performed in 730 TAVR and 684 surgical patients from March 2016 to May 2019. The Kaplan-Meier rates for the complete 2-year primary endpoint of death or disabling stroke were 4.3% in the TAVR group and 6.3% in the surgery group (P = 0.084). These rates were comparable to the interim Bayesian rates of 5.3% with TAVR and 6.7% with surgery (difference: -1.4%; 95% Bayesian credible interval: -4.9% to 2.1%). All-cause mortality rates were 3.5% vs 4.4% (P = 0.366), and disabling stroke rates were 1.5% vs 2.7% (P = 0.119), respectively. Between years 1 and 2, there was no convergence of the primary outcome curves. CONCLUSIONS: The complete 2-year follow-up from the Evolut Low Risk Trial found that TAVR is noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke, with event rates that were slightly better than those predicted by using the Bayesian analysis. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients [Evolut Low Risk Trial]; NCT02701283).


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Bayes Theorem , Heart Valve Prosthesis/adverse effects , Humans , Prosthesis Design , Risk Factors , Stroke/epidemiology , Stroke/etiology , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...