1.
Micromachines (Basel) ; 9(7)2018 Jul 10.
Article in English | MEDLINE | ID: mdl-30424280

ABSTRACT

This paper proposes a reconfigurable sensor analog front-end using low-noise chopper-stabilized delta-sigma capacitance-to-digital converter (CDC) for capacitive microsensors. The proposed reconfigurable sensor analog front-end can drive both capacitive microsensors and voltage signals by direct conversion without a front-end amplifier. The reconfigurable scheme of the front-end can be implemented in various multi-mode applications, where it is equipped with a fully integrated temperature sensor. A chopper stabilization technique is implemented here to achieve a low-noise characteristic by reducing unexpected low-frequency noises such as offsets and flicker noise. The prototype chip of the proposed sensor analog front-end is fabricated by a standard 0.18-µm 1-poly-6-metal (1P6M) complementary metal-oxide-semiconductor (CMOS) process. It occupies a total active area of 5.37 mm² and achieves an effective resolution of 16.3-bit. The total power consumption is 0.843 mW with a 1.8 V power supply.

2.
Technol Health Care ; 26(1): 3-9, 2018.
Article in English | MEDLINE | ID: mdl-29060948

ABSTRACT

BACKGROUND: Wearable healthcare systems require measurements from electrocardiograms (ECGs) and photoplethysmograms (PPGs), and the blood pressure of the user. The pulse transit time (PTT) can be calculated by measuring the ECG and PPG simultaneously. Continuous-time blood pressure without using an air cuff can be estimated by using the PTT. OBJECTIVE: This paper presents a biosignal acquisition integrated circuit (IC) that can simultaneously measure the ECG and PPG for wearable healthcare applications. METHODS: Included in this biosignal acquisition circuit are a voltage mode instrumentation amplifier (IA) for ECG acquisition and a current mode transimpedance amplifier for PPG acquisition. The analog outputs from the ECG and PPG channels are muxed and converted to digital signals using 12-bit successive approximation register (SAR) analog-to-digital converter (ADC). RESULTS: The proposed IC is fabricated by using a standard 0.18 µm CMOS process with an active area of 14.44 mm2. The total current consumption for the multichannel IC is 327 µA with a 3.3 V supply. The measured input referred noise of ECG readout channel is 1.3 µVRMS with a bandwidth of 0.5 Hz to 100 Hz. And the measured input referred current noise of the PPG readout channel is 0.122 nA/√Hz with a bandwidth of 0.5 Hz to 100 Hz. CONCLUSIONS: The proposed IC, which is implemented using various circuit techniques, can measure ECG and PPG signals simultaneously to calculate the PTT for wearable healthcare applications.


Subject(s)
Clothing , Equipment Design , Monitoring, Ambulatory/methods , Photoplethysmography/methods , Textiles , Electrocardiography, Ambulatory/instrumentation , Electrocardiography, Ambulatory/methods , Humans , Monitoring, Ambulatory/instrumentation , Photoplethysmography/instrumentation , Signal Processing, Computer-Assisted , Telemetry , Wearable Electronic Devices
SELECTION OF CITATIONS
SEARCH DETAIL
...