Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Case Rep ; 12(6): e9039, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38840753

ABSTRACT

The newly-proposed tandem approach, Wire ThRoUgh Snare Twice (Wire TRUST) is effective for grasping a lead with inaccessible ends. This case report shows that Wire TRUST can also enable successful extraction of a left ventricular lead by iteratively grasping and repositioning to the distal portion of the lead.

4.
J Cardiovasc Electrophysiol ; 34(9): 1990-1995, 2023 09.
Article in English | MEDLINE | ID: mdl-37579218

ABSTRACT

INTRODUCTION: Transvenous lead extraction (TLE) is a crucial procedure for managing cardiac implantable electronic devices. The use of a combined superior and femoral approach has been found to enhance the success rate of TLE. This report introduces a novel technique, named "Wire ThRoUgh Snare Twice" (Wire TRUST), for effectively grasping a lead without a free end during TLE. METHOD: The Wire TRUST technique was applied in a case involving a 49-year-old male patient requiring TLE due to electrical artifact on the right ventricular (RV) lead, replacement of the RV lead, and pacemaker generator exchange. The Wire TRUST technique involved the insertion of a 4-Fr pigtail catheter and a 6-Fr snare catheter through the 14-Fr sheath inserted from the right common femoral vein. The 4-Fr pigtail catheter was hooked to the RV lead under multidirectional fluoroscopic guidance in the right atrium. The 0.014-in. guidewire was advanced through the pigtail catheter, crossing the RV lead until reaching the inferior vena cava. Subsequently, the distal end of the 0.014-in. guidewire was captured using a snare and pulled, facilitating externalization of the guidewire. After externalization, both ends of the 0.014-in. guidewire were passed through the snare outside the body and reinserted into the 14-Fr sheath. By simultaneously advancing and closing the snare while applying tension to the 0.014-in. guidewire, a secure grip on the lead without free ends was achieved. RESULTS: The Wire TRUST technique enabled successful lead extraction and replacement without any complications. The technique facilitated the co-axial alignment of the powered sheath with the RV lead, ensuring safe and efficient extraction. CONCLUSION: The Wire TRUST technique presents a novel and effective approach for grasping leads with inaccessible ends during TLE.


Subject(s)
Pacemaker, Artificial , Male , Humans , Middle Aged , Cardiac Catheterization , Heart Ventricles , Device Removal/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...