Article in English | MEDLINE | ID: mdl-15607717

ABSTRACT

The clinical development of a sensitizer for photodynamic therapy (PDT) requires the structural identification of the photoproducts and their quantification in biological fluids and tissues. We describe the LC-MS identification of the most important photoproducts of a cationic phthalocyanine sensitizer (RLP068/Cl) and a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of the main photoproduct (the cationic phthalimide derivative 3-[(1,3-dioxo-2,3-dihydro-1H-isoindol-4-yl)oxy]-N,N,N-trimethylbenzenaminium chloride) in rabbit plasma. The tri-deuterated product was used as co-eluting internal standard. The cationic photoproduct was isolated from plasma samples by protein precipitation with perchloric acid in methanol (7%, v/v). HPLC step was performed on a Phenomenex Synergi Hydro-RP column (20 mm x 2.0 mm, 2 microm particles) with a mobile phase of 0.5% (v/v) aqueous TFA/methanol (85:15, v/v). Flow rate was 0.2 mL/min and 40 microL injection were performed. Run time was 10 min. Detection was achieved by means of a Bruker Esquire 3000+ ion trap mass spectrometer equipped with an ESI source working in positive mode. A multiple reaction monitoring method following the transitions 297.1 --> 282.1 for the analyte and 300.1 --> 282.1+285.1 for the internal standard was used. The analytical method was validated over the concentration range 0.46-91.2 ng/mL and lower limits of detection (LLOD) and quantification (LLOQ) respectively of 0.2 and 0.5 ng/mL were found.


Subject(s)
Bacterial Infections/drug therapy , Chromatography, High Pressure Liquid/methods , Indoles/blood , Organometallic Compounds/blood , Photochemotherapy , Spectrometry, Mass, Electrospray Ionization/methods , Animals , Calibration , Cations , Indoles/therapeutic use , Organometallic Compounds/therapeutic use , Rabbits , Reproducibility of Results , Sensitivity and Specificity
2.
Article in English | MEDLINE | ID: mdl-15282108

ABSTRACT

The development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of the tetracationic zinc(II) phthalocyanine derivative RLP068 in rabbit serum is described. The dodecadeuterated product (RLP068-D12) was used as co-eluting internal standard. RLP068 was isolated from serum samples by solid-phase extraction using weak cationic exchange cartridges (WCX). An oxidative derivatisation was used in order to simplify the peculiar HPLC and MS behaviour of the analyte and thus increasing sensitivity. Liquid Chromatography was carried out on a Polaris C18 Ether column (50 mm x 2.0 mm) with an isocratic run of 0.5% aqueous TFA/methanol. Detection was achieved by means of a Bruker Esquire 3000+ Ion Trap Mass Spectrometer equipped with an ESI source working in positive mode. A Multiple Reaction Monitoring method following the transitions 297.1 --> 282.1 for the analyte and 300.1 --> 282.1 + 285.1 for the internal standard was used. The analytical method was validated over the concentration range 2-65 ng/mL. lower limits of detection (LLOD) and quantification (LLOQ) were respectively 1 and 2 ng/mL. The method is innovative and applicable to pharmacokinetic studies.


Subject(s)
Chromatography, High Pressure Liquid/methods , Indoles/blood , Organometallic Compounds/blood , Spectrometry, Mass, Electrospray Ionization/methods , Zinc/chemistry , Animals , Cations , Rabbits , Reproducibility of Results , Sensitivity and Specificity