Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
2.
J Glaucoma ; 33(1): 15-23, 2024 01 01.
Article in English | MEDLINE | ID: mdl-37647317

ABSTRACT

PRCIS: Monitoring visual fields (VFs) through virtual reality devices proved to have good inter-test and test-retest reliability, as well as easy usability, when self-administered by individuals with and without VF defects in a remote setting. PURPOSE: To assess the reliability of remote, self-administered VF monitoring using a virtual reality VF (VRVF) device in individuals without ocular disease and with stable VF defects. MATERIALS AND METHODS: Individuals without ocular disease and with stable defects were recruited. All participants had a baseline standard automated perimetry (SAP) test. Participants tested remotely on a VRVF device for 4 weeks (examinations V 1 , V 2 , V 3 , and V 4 ), with the last 3 unassisted. The mean sensitivities of VRVF results were compared with each other and to SAP results for reliability. RESULTS: A total of 42 eyes from 21 participants were tested on the VRVF device. Participants tested consistently although external factors impacted outcomes. VRVF results were in reasonable agreement with the baseline SAP. Examinations performed by the cohort with stable defects evinced better agreement with SAP examinations (V2, P = 0.79; V3, P = 0.39; V4, P = 0.35) than those reported by the cohort without ocular disease (V2, P = 0.02; V3, P = 0.15; V4, P = 0.22), where the null hypothesis is that the instruments agree. Fixation losses were high and variable in VRVF examinations compared with those of SAP, particularly in certain test takers. Participants considered the device comfortable and easy to use. CONCLUSIONS: Self-administered, remote VF tests on a VRVF device showed satisfactory test-retest reliability, good inter-test agreement with SAP, and acceptability by its users. External factors may impact at-home testing and age and visual impairment may hinder fixation. Future studies to expand the sample size and understand inconsistencies in fixation losses are recommended.


Subject(s)
Telemedicine , Vision, Low , Humans , Visual Field Tests/methods , Visual Fields , Pilot Projects , Reproducibility of Results , Intraocular Pressure , Prospective Studies , Vision Disorders/diagnosis
3.
Eye (Lond) ; 37(15): 3157-3173, 2023 10.
Article in English | MEDLINE | ID: mdl-36949247

ABSTRACT

We present a novel comprehensive literature review of studies of the psychosocial functioning (PF) and quality of life (QoL) of patients with childhood glaucoma and their caregivers. Our findings demonstrate variable study quality and approach, as well as inconsistent results relating to the association of glaucoma-specific factors and sociodemographic variables with measured PF and QoL. Future studies should focus on the development of culturally cognizant and standardized assessment tools, execution of multi-center longitudinal studies with global representation, evaluation of PF and QoL among siblings and childhood glaucoma providers, and implementation of interventions to improve patient and caregiver PF and QoL.


Subject(s)
Glaucoma , Quality of Life , Humans , Quality of Life/psychology , Psychosocial Functioning , Glaucoma/psychology , Siblings , Caregivers/psychology
4.
Ophthalmic Plast Reconstr Surg ; 39(4): 381-385, 2023.
Article in English | MEDLINE | ID: mdl-36852832

ABSTRACT

PURPOSE: To assess the sensitivity and specificity of superior visual field tests administered in virtual reality (VR) with eye tracking (VR-ET) and without eye tracking (VR 0 ) for the fulfillment of insurance coverage criteria for functional upper eyelid surgery as compared with standard automated perimetry (SAP). METHODS: This prospective cross-sectional study included 78 eyes from 41 patients with ptosis, brow ptosis, and dermatochalasis undergoing functional upper eyelid surgery evaluation. Participants underwent serial superior visual field tests using SAP and VR 0 or VR-ET in randomized order. Fulfillment of insurance coverage criteria for blepharoplasty was defined as a 30% increase in the grid seen from the untaped to the taped state. The main outcome measure was the sensitivity and specificity of VR 0 , VR-ET, and overall VR in meeting insurance coverage criteria as compared with SAP. RESULTS: VR had a sensitivity of 84.1% and specificity of 67.6%, with no significant difference between VR 0 and VR-ET. SAP agreed on insurance coverage criteria fulfillment with VR 0 in 28 (71.8%) eyes and with VR-ET in 32 (82.1%) eyes. Insurance coverage criteria fulfillment rates varied significantly by diagnosis on SAP ( p = 0.012) but not VR ( p = 0.059). CONCLUSIONS: VR may be an alternative to SAP for functional upper eyelid surgery evaluation. Future studies are needed to determine differences in patient satisfaction, testing and waiting time, and test-retest reliability between VR and SAP.


Subject(s)
Visual Field Tests , Visual Fields , Humans , Pilot Projects , Prospective Studies , Reproducibility of Results , Eye-Tracking Technology , Cross-Sectional Studies , Eyelids/surgery
5.
Ophthalmol Glaucoma ; 6(3): 316-321, 2023.
Article in English | MEDLINE | ID: mdl-36126915

ABSTRACT

PURPOSE: Even though physician burnout can negatively impact physical/mental health, ophthalmologists' quality of life (QOL) is understudied. Although managing high-risk diseases like pediatric glaucoma may lead to compassion satisfaction (CS), the responsibility of caring for very sick, demanding patients has been linked to higher burnout. Burnout and secondary traumatic stress (STS) constitute compassion fatigue, the negative effects resulting from helping those who experience stress. We assessed professional QOL, including CS, burnout, and STS, along with associated factors among pediatric glaucoma providers managing potentially blinding disease in children. DESIGN: Cross-sectional survey study. PARTICIPANTS: Pediatric glaucoma providers in the Childhood Glaucoma Research Network, American Glaucoma Society, and Indian Paediatric Glaucoma Society. METHODS: Participants were sent an electronic survey of a validated instrument (Professional Quality of Life-Version 5) designed to measure burnout, STS, and CS, as well as questions related to demographics, lifestyle, training, and practice. Burnout, STS, and CS scores range from 10 to 50 and are classified into low (≤ 22), moderate (23-41), and high (≥ 42) subgroups. MAIN OUTCOME MEASURES: Burnout, STS, and CS. RESULTS: Seventy-six pediatric glaucoma providers completed the survey with resulting burnout (22.6 ± 6.3), STS (22.7 ± 6.1), and CS (42.3 ± 6.7) scores. Most respondents had low burnout (43, 56.6%), low STS (44, 57.9%) and high CS (48, 63.2%), though more than a third reported moderate burnout (33, 43.4%), STS (31, 40.8%), and CS (27, 35.6%). Older age and more years in practice correlated positively with CS, and age correlated negatively with STS (P < 0.05 for all). Frequent workday fatigue correlated positively with burnout and STS and negatively with CS, and frequent caffeine consumption correlated positively with burnout and negatively with CS (P < 0.05 for all). Members of a married or unmarried couple had significantly lower CS scores than single, divorced, or separated respondents (P = 0.022). CONCLUSIONS: Pediatric glaucoma providers derive a high level of professional satisfaction from their work, though many report moderate burnout and STS. To comprehensively address provider QOL, CS, and both components of compassion fatigue must be considered. Initial efforts may be focused on younger, early-career providers as this group had lower professional QOL scores than their older, late-career counterparts. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.


Subject(s)
Burnout, Professional , Compassion Fatigue , Glaucoma , Child , Humans , United States , Compassion Fatigue/psychology , Quality of Life , Cross-Sectional Studies , Burnout, Professional/epidemiology , Burnout, Professional/etiology , Burnout, Professional/psychology
SELECTION OF CITATIONS
SEARCH DETAIL
...