Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Diagnostics (Basel) ; 13(23)2023 Nov 28.
Article in English | MEDLINE | ID: mdl-38066786

ABSTRACT

This study aimed to assess the effectiveness of saline sealing in reducing the incidence of pneumothorax after a CT-guided lung biopsy. This was a retrospective case-control study of patients who underwent CT-guided biopsies for lung tumors using 18 G semiautomatic core needles in conjunction with 17 G coaxial needles. The patients were divided into two consecutive groups: a historical Group A (n = 111), who did not receive saline sealing, and Group B (n = 87), who received saline sealing. In Group B, NaCl 0.9% was injected through the coaxial needle upon its removal. The incidence of pneumothorax and chest tube insertion was compared between the two groups. Multivariate logistic regression was performed to verify the contribution of other pneumothorax risk factors. The study included 198 patients, with 111 in Group A and 87 in Group B. There was a significantly (p = 0.02) higher pneumothorax rate in Group A (35.1%, n = 39) compared to Group B (20.7%, n = 18). The difference regarding chest tube insertion was not significant (p = 0.1), despite a tendency towards more insertions in Group A (5.4%, n = 6), compared to Group B (1.1%, n = 1). Among the risk factors for pneumothorax, only the presence of emphysema (OR = 3.5, p = 0.0007) and belonging to Group A (OR = 2.2, p = 0.02) were significant. Saline sealing of the needle tract after a CT-guided lung biopsy can significantly reduce the incidence of pneumothorax. This technique is safe, readily available, and inexpensive, and should be considered as a routine preventive measure during this procedure.

2.
Cancers (Basel) ; 15(13)2023 Jun 23.
Article in English | MEDLINE | ID: mdl-37444429

ABSTRACT

The aim of this study was to assess the ability of MRI radiomic features to differentiate between benign parotid gland tumors (BPGT) and malignant parotid gland tumors (MPGT). This retrospective study included 93 patients who underwent MRI examinations of the head and neck region (78 patients presenting unique PGT, while 15 patients presented double PGT). A total of 108 PGT with histological confirmation were eligible for the radiomic analysis and were assigned to a training group (n = 83; 58 BPGT; 25 MPGT) and a testing group (n = 25; 16 BPGT; 9 MPGT). The radiomic features were extracted from 3D segmentations of the PGT on the T2-weighted and fat-saturated, contrast-enhanced T1-weighted images. Following feature reduction techniques, including LASSO regression analysis, a radiomic signature (RS) was built with five radiomic features. The RS presented a good diagnostic performance in differentiating between PGT, achieving an area under the curve (AUC) of 0.852 (p < 0.001) in the training set and 0.786 (p = 0.017) in the testing set. In both datasets, the RS proved to have lower values in the BPGT group as compared to MPGT group (p < 0.001 and p = 0.023, respectively). The multivariate analysis revealed that RS was independently associated with PGT malignancy, together with the ill-defined margin pattern (p = 0.031, p = 0.001, respectively). The complex model, using clinical data, MRI features and the RS, presented a higher diagnostic performance (AUC of 0.976) in comparison to the RS alone. MRI-based radiomic features could be considered potential additional imaging biomarkers able to discriminate between benign and malignant parotid gland tumors.

3.
Cancers (Basel) ; 15(5)2023 Feb 22.
Article in English | MEDLINE | ID: mdl-36900173

ABSTRACT

Non-Hodgkin Lymphoma (NHL) represents a severe complication and the main cause of morbidity in patients with primary Sjögren's syndrome (pSS). This study aimed to assess the role of textural analysis (TA) in revealing lymphoma-associated imaging parameters in the parotid gland (PG) parenchyma of patients with pSS. This retrospective study included a total of 36 patients (54.93 ± 13.34 years old; 91.6% females) diagnosed with pSS according to the American College of Rheumatology and the European League Against Rheumatism criteria (24 subjects with pSS and no lymphomatous proliferation; 12 subjects with pSS and NHL development in the PG, confirmed by the histopathological analysis). All subjects underwent MR scanning between January 2018 and October 2022. The coronal STIR PROPELLER sequence was employed to segment PG and perform TA using the MaZda5 software. A total of 65 PGs underwent segmentation and texture feature extraction (48 PGs were included in the pSS control group, and 17 PGs were included in the pSS NHL group). Following parameter reduction techniques, univariate analysis, multivariate regression, and receiver operating characteristics (ROC) analysis, the following TA parameters proved to be independently associated with NHL development in pSS: CH4S6_Sum_Variance and CV4S6_Inverse_Difference_Moment, with an area under ROC of 0.800 and 0.875, respectively. The radiomic model (resulting by combining the two previously independent TA features), presented 94.12% sensitivity and 85.42% specificity in differentiating between the two studied groups, reaching the highest area under ROC of 0.931 for the chosen cutoff value of 1.556. This study suggests the potential role of radiomics in revealing new imaging biomarkers that might serve as useful predictors for lymphoma development in patients with pSS. Further research on multicentric cohorts is warranted to confirm the obtained results and the added benefit of TA in risk stratification for patients with pSS.

4.
Diagnostics (Basel) ; 12(10)2022 Oct 13.
Article in English | MEDLINE | ID: mdl-36292163

ABSTRACT

Viscosity and elasticity represent biomechanical properties of soft tissues that suffer changes during the pathophysiological alterations of the tissue in various conditions. This study aimed to determine average viscosity values for the thyroid gland and to evaluate the potential influences of age, gender and body mass index (BMI), using a recent technique Viscosity Plane-wave UltraSound (Vi PLUS). A total of 85 healthy Caucasian volunteers (56 women and 29 men, median age of 29 years, range 17−81 years) were included in this prospective monocentric study conducted between January 2022 and March 2022. Thyroid viscosity was measured using the SuperSonic MACH 30® Ultrasound system (Aixplorer, SuperSonic Imagine, Aix-en-Provence, France), equipped with a curvilinear C6-IX transducer that allows simultaneous quantification of the viscosity and stiffness. The mean thyroid viscosity measurement value was 2.63 ± 0.47 Pa.s. No statistically significant differences were detected between the left and the right lobes of the thyroid gland. A significant positive correlation was found between thyroid viscosity and elasticity (r = 0.685, p < 0.0001). There was no statistically significant correlation between body mass index (BMI) and thyroid gland viscosity and elasticity values (r = 0.215, p = 0.053; r = 0.106, p = 0.333). No correlation between viscosity and gender was established (p > 0.05). Vi PLUS represents a new and promising ultrasonographic technique that can provide helpful information for evaluating the thyroid parenchyma, similar to elastography. The effect of the potential confounding factors on thyroid viscosity was negligible, except for BMI.

5.
Int J Mol Sci ; 23(17)2022 Sep 02.
Article in English | MEDLINE | ID: mdl-36077442

ABSTRACT

This study aimed to assess the effectiveness of MRI-based texture features of the lacrimal glands (LG) in augmenting the imaging differentiation between primary Sjögren's Syndrome (pSS) affected LG and healthy LG, as well as to emphasize the possible importance of radiomics in pSS early-imaging diagnosis. The MRI examinations of 23 patients diagnosed with pSS and 23 healthy controls were retrospectively included. Texture features of both LG were extracted from a coronal post-contrast T1-weighted sequence, using a dedicated software. The ability of texture features to discriminate between healthy and pSS lacrimal glands was performed through univariate, multivariate, and receiver operating characteristics analysis. Two quantitative textural analysis features, RunLengthNonUniformityNormalized (RLNonUN) and Maximum2DDiameterColumn (Max2DDC), were independent predictors of pSS-affected glands (p < 0.001). Their combined ability was able to identify pSS LG with 91.67% sensitivity and 83.33% specificity. MRI-based texture features have the potential to function as quantitative additional criteria that could increase the diagnostic accuracy of pSS-affected LG.


Subject(s)
Lacrimal Apparatus , Sjogren's Syndrome , Humans , Lacrimal Apparatus/diagnostic imaging , Magnetic Resonance Imaging , ROC Curve , Retrospective Studies , Sjogren's Syndrome/diagnostic imaging
6.
Diagnostics (Basel) ; 12(9)2022 Sep 02.
Article in English | MEDLINE | ID: mdl-36140536

ABSTRACT

Viscosity is a novel parameter, recently introduced in the use of elastographic techniques, correlating to shear-wave dispersion. The purpose of this study was to provide normal reference viscosity values for the peripheral muscles in healthy volunteers. This prospective study included 38 subjects who underwent US examinations between November 2021 and January 2022. Measurements were taken on the calf and the deltoid muscles in both pre- and post-contraction states. The age range was 21-29 years, with a median of 26 years. The SWE and ViPLUS values in the deltoid muscles were significantly higher than in the soleus muscles in both pre- and post-contraction sets (p = 0.002). There were statistically significant differences between the pre- and post-contraction values for both the SWE and ViPLUS values in the subgroup analysis. The ICC estimates and the 95% confidence intervals were based on a mean rating (k = 2), an absolute agreement, and a two-way random-effects model, demonstrating excellent agreement between the measurements taken by the two examiners.

7.
Diagnostics (Basel) ; 12(8)2022 Aug 13.
Article in English | MEDLINE | ID: mdl-36010313

ABSTRACT

Biological soft tissues are characterized by viscoelastic properties. The propagation of shear waves within tissues is influenced by both elasticity, which is linked to the shear wave speed, and viscosity, which is linked to the shear wave dispersion. This study aimed to functionally assess the parotid glands (PG) and submandibular glands (SMG) in a group of 40 healthy subjects using the novel Viscosity PLUS (Vi.PLUS) and 2D Shear-Wave Elastography PLUS (2D-SWE.PLUS) techniques. The viscosity and stiffness of PG and SMG were measured before and after gustatory stimulation with a sialagogue agent (commercially available lemon juice) using the new SuperSonic MACH 30 ultrasound system equipped with a curvilinear C6-1X transducer. PG presented a mean basal viscosity and elasticity of 2.10 ± 0.19 Pa.s and 11.32 ± 1.91 kPa, respectively, which significantly increased poststimulation to 2.39 ± 0.17 Pa.s (p < 0.001) and 12.58 ± 1.92 kPa (p < 0.001), respectively. SMG did not present statistically increased values of viscosity and elasticity following stimulation (2.31 ± 015 Pa.s vs. 2.37 ± 0.18 Pa.s, p = 0.086, and 10.40 ± 1.64 kPa vs. 10.90 ± 1.98 kPa, p = 0.074, respectively). Vi.PLUS measurements presented a good positive correlation with 2D-SWE.PLUS values for PG and SMG, before and after stimulation. Gender and BMI were not confounding factors for these two parameters. Vi.PLUS represents an innovative non-invasive imaging technique that, together with 2D-SWE.PLUS proves to be useful in functionally assessing the major salivary glands in healthy subjects.

SELECTION OF CITATIONS
SEARCH DETAIL
...