Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
J Knee Surg ; 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38599605

ABSTRACT

This study aimed to test and compare the biomechanical properties of three tibial fixation methods of anterior cruciate ligament (ACL) tendon grafts under cyclic load and load-to-failure testing in the bovine proximal tibiae, comprising (1) staple fixation alone, (2) interference screw fixation alone, and (3) interference screw fixation with a supplementary staple. Twenty-four bovine tibiae used in the study were divided into three groups (eight proximal tibiae in each group) based on tibial fixation methods of ACL tendon grafts: group A (a spiked ligament staple alone), group B (a cannulated interference screw alone), and group C (a cannulated interference screw with a supplementary staple). Each graft fixation was exposed to cyclic loading conditions. Significant differences were determined in failure load among the three groups (p = 0.008). The mean failure load was significantly higher in group B (717.04 ± 218.51 N) than in group A (308.03 ± 17.22 N) (p = 0.006). No significant differences were observed among the groups regarding axial stiffness (p = 0.442). Cyclic displacement differed significantly among the three groups (p = 0.005). In pairwise comparisons, the mean cyclic displacement was significantly higher in group A (8.22 ± 3.24 mm) compared with group C (1.49 ± 0.41 mm) (p = 0.005). Failure displacement varied considerably among the groups (p = 0.037). Although group B (15.53 ± 6.43 mm) exhibited a greater mean failure displacement than both group A (4.9 ± 0.75 mm) and group C (8.84 ± 4.65 mm), these differences did not reach statistical significance (p = 0.602 and p = 0.329, respectively). Interference screw fixation alone and supplementary staple fixation have biomechanically similar characteristics in terms of initial strength and stiffness of tibial ACL soft tissue graft fixation. Regardless of staple use, an interference screw with the same diameter as the tibial tunnel can ensure sufficient tensile strength in tibial ACL graft fixation.

2.
Ulus Travma Acil Cerrahi Derg ; 29(10): 1091-1097, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37791442

ABSTRACT

BACKGROUND: The aim of this study is to investigate mechanical properties of minimally invasive plate osteosynthesis (MIPO), supracutaneousplating (SP), and unilateral external fixators (UEF) which can be performed for open tibial fractures. METHODS: An unstable diaphysial tibia fracture was created in 60 fresh sheep tibia specimens by performing an osteotomy at the middle of bones. Specimens were divided into 3 groups. Specimens underwent fracture fixation with a standard MIPO technique, im-planting the plate 15 mm from the bone for SP group. Unilateral uniplanar external fixators were achieved for UEF group. First, thirty specimens (10 specimen for each group) were loaded vertically along the tibial axis to 1800 N. Second, other 30 preperated bones were used for cyclical loading to avoid metal fatigue. For dynamic tests, a 350 N force was applied for 10,000 cycles. RESULTS: In compression testing (vertical loading up to 1800 N) of the three fixation instruments; construct stiffness was highest in MIPO group when compared with SP and UEF groups. While the stiffness of the MIPO group was similar to SP group, it was statistically higher than UEF group (P=0.08 and P=0.002, respectively). SP group was significantly stiffer than UEF group (P=0.0021). The mean peak load was highest in SP group and lowest in UEF group. The peak load in SP group was similar to the MIPO group, it was statistically higher than the UEF group (P=0.743 and P=0.002, respectively). CONCLUSION: Based on the biomechanical properties from this in vitro animal model study, SP technique was biomechanically stronger than UEF and has similar biomechanical properties with MIPO in terms of axial loading.


Subject(s)
Fractures, Open , Tibial Fractures , Animals , Sheep , Tibial Fractures/surgery , Fracture Fixation, Internal/methods , Tibia/surgery , Bone Plates , Models, Animal , Minimally Invasive Surgical Procedures/methods , Biomechanical Phenomena , Treatment Outcome
3.
Jt Dis Relat Surg ; 33(3): 580-587, 2022.
Article in English | MEDLINE | ID: mdl-36345186

ABSTRACT

OBJECTIVES: This study aims to compare the radiological outcomes of unicompartmental knee arthroplasty (UKA) performed by a navigation-based robotic system versus Microplasty® instrumentation. PATIENTS AND METHODS: Between January 2018 and January 2019, a total of 90 knees of 75 patients (65 males, 10 females; mean age: 62.0±9.4 years; range, 50 to 73 years) were included. Among these, 54 knees underwent Oxford mobile-bearing UKA with an Microplasty® instrumentation set and 36 knees were operated with the aid of a Restoris® MCK with MAKO navigation-based robotic system. Postoperative anteroposterior and lateral X-rays of all patients were evaluated according to nine different parameters. On the femoral side, femoral varus-valgus angle, flexion-extension angle, femoral condyle posterior fit; on tibial side, tibial component varus/valgus, tibial posterior slope, medial, anterior, posterior and lateral fit of tibial component assessed. RESULTS: There was no significant difference between groups in terms of age, sex, and affected side. On the femoral side, no significant difference was observed in the component position between groups. On the tibial side, tibial component medial fit (p=0.032) and anterior fit (p=0.007) were better in navigation-based robotic system group. CONCLUSION: Microplasty® instrumentation may lead to comparable implant positioning compared to a tactile-based navigated robotic instrumentation.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Robotic Surgical Procedures , Male , Female , Humans , Middle Aged , Aged , Knee Joint/diagnostic imaging , Knee Joint/surgery , Tibia/surgery
4.
Medicine (Baltimore) ; 101(38): e30823, 2022 Sep 23.
Article in English | MEDLINE | ID: mdl-36197255

ABSTRACT

Many different methods and drain clamping periods have been described in systemic and local tranexamic acid (TXA) applications, and the superiority of the methods to each other has not been clearly demonstrated. The method of local infusion in combined TXA applications may not alter the Hb drop or total or hidden blood loss. We aim to compare two different combined TXA application methods. We retrospectively analyzed 182 patients who underwent total knee arthroplasty between 2018 and 2021. Patients over 40 years of age who underwent TKA for degenerative knee arthritis were included in the study. Unicondylar, revision, or bilateral arthroplasties and patients with the cardiovascular or cerebrovascular disease were excluded from the study. All patients in the study received 1 g TXA intravenously half an hour before the incision. For the first group, 1 g TXA was given intra-articularly at the drain site after closure, and the clamp was kept closed for 1 hour. In the second group, the drain was clamped for an additional 6 hours, and a 1 g intravenous dose was administered at the 5th hour postoperatively. No local applications were used in the control group. Total, hidden, and visible blood loss (total blood loss, hidden blood loss, visible blood loss), postoperative decreases in hemoglobin and hematocrit level (ΔHgb, ΔHtc), blood transfusion rates, and hospital stay durations were evaluated. There were 72 patients in the first group, 52 in the second, and 58 in control. A total of 37 patients received one or more blood transfusions postoperatively, and there was no statistical difference in the need for blood transfusions between the groups (P = .255). Although a statistically significant difference (P = .001) in total blood loss, hidden blood loss, visible blood loss and ΔHgb values was observed between the groups, the difference between the first and second groups was insignificant (P = .512). The duration of hospital stay was observed to be less in the first and second groups (P = .024). Local and systemic TXA applications were observed to be more effective than only systemic applications in reducing blood loss after total knee arthroplasty, regardless of the local method.


Subject(s)
Antifibrinolytic Agents , Arthroplasty, Replacement, Knee , Tranexamic Acid , Adult , Arthroplasty, Replacement, Knee/methods , Blood Loss, Surgical/prevention & control , Cohort Studies , Constriction , Hemoglobins/analysis , Humans , Middle Aged , Postoperative Hemorrhage/drug therapy , Postoperative Hemorrhage/prevention & control , Retrospective Studies , Tranexamic Acid/therapeutic use
5.
J Am Podiatr Med Assoc ; : 1-16, 2022 Aug 29.
Article in English | MEDLINE | ID: mdl-36040860

ABSTRACT

BACKGROUND: Many surgical techniques have been reported for the treatment of ingrown toenails. Occurrences of infection after matricectomy procedures could cause clinicians to prefer using external braces to treat ingrown toenails. This study compares patients with ingrown toenails who underwent the nail fixation technique and the Winograd technique. METHODS: Patients who underwent ingrown toenail surgery were retrospectively reviewed. The patients' demographic characteristics (age, gender, body mass index [BMI] morphology according to Heifetz classification, surgical technique, visual analog scale (VAS) values, time to return to daily activities (days), complications, and satisfaction levels were all recorded. RESULTS: Seventy patients were included in the study. Of the patients, 33 underwent nail fixation and 37 underwent the Winograd technique. No significant statistical differences were found in terms of patients' age, gender, BMI, preoperative clinical features, long-term satisfaction, and ingrown toenail recurrence rates between the two groups, but time to return to daily activities and VAS values were statistically significantly lower in patients treated using nail fixation compared with the Winograd technique. CONCLUSION: Nail fixation can be an effective surgical treatment option for an ingrown toenail.

6.
Jt Dis Relat Surg ; 33(1): 187-192, 2022.
Article in English | MEDLINE | ID: mdl-35361094

ABSTRACT

OBJECTIVES: This study aims to evaluate the effect of surgical experience on reliability for Boyd-Griffin, Evans/Jensen, Evans, Orthopaedic Trauma Association (main and subgroups), and Tronzo classification systems. PATIENTS AND METHODS: Between January 2013 and December 2014, radiological images of a total of 60 patients (13 males, 47 females; mean age: 78.9±21.9 years; range, 61 to 96 years) with the diagnosis of intertrochanteric femur fracture were analyzed. Radiographs were evaluated and classified by five residents and five orthopedics and traumatology surgeons according to the Evans, Boyd-Griffin, Evans/Jensen, OTA, and Tronzo classification systems. Intra- and interobserver reliability were calculated using the kappa statistics. RESULTS: The worst intraobserver compatibility among the residents was the classification system with OTA subgroups (κ=0.516), while the classification system with the best intraobserver fit was found to be OTA main groups (κ=0.744). The worst agreement among surgeons was in the Evans classification system (κ=0.456). However, the best intraobserver agreement was in the OTA main groups (κ=0.741). The best interobserver agreement was observed regarding the OTA main groups (κ=0.699). CONCLUSION: The classification that has the best harmony both among residents and surgeons, and between residents and surgeons is the OTA main group classification.


Subject(s)
Hip Fractures , Traumatology , Aged , Aged, 80 and over , Female , Femur , Hip Fractures/diagnostic imaging , Hip Fractures/surgery , Humans , Male , Middle Aged , Observer Variation , Reproducibility of Results
7.
Hip Int ; 32(3): 345-352, 2022 May.
Article in English | MEDLINE | ID: mdl-32921171

ABSTRACT

BACKGROUND: Subtrochanteric femoral shortening is used during total hip arthroplasty for high hip dislocation in developmental dysplasia of hip patients. METHODS: We mechanically tested the stability of various commonly used subtrochanteric osteotomy techniques. As the equivalent of a femoral stem placed in a shortened femur without any stable fixation at the osteotomy line, 2 polyvinylchloride pipes were loosely intertwined. 4 different osteotomies (Z-subtrochanteric osteotomy, oblique-45° osteotomy, double Chevron-90° and 120° subtrochanteric osteotomy) were simulated. Torsional and axial loads were applied, and torsional stiffness was calculated for each test model. RESULTS: Z, double Chevron-90° and 120° subtrochanteric osteotomy models demonstrated lower mean torsional stiffness than oblique-45° osteotomy. With the highest torsional stiffness oblique-45° provides the best stability for treatment of high dislocation hips when a subtrochanteric osteotomy is added. CONCLUSIONS: This matches our previous clinical experience. Oblique osteotomy may also provide higher contact surfaces in the osteotomy lines to promote bone healing.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Dislocation, Congenital , Hip Dislocation , Arthroplasty, Replacement, Hip/methods , Femur/diagnostic imaging , Femur/surgery , Hip Dislocation/diagnostic imaging , Hip Dislocation/surgery , Hip Dislocation, Congenital/diagnostic imaging , Hip Dislocation, Congenital/surgery , Humans , Osteotomy/methods , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...