Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Laryngoscope Investig Otolaryngol ; 7(3): 840-846, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35734043

ABSTRACT

Introduction: The Hannover Coupler version 2 (HC2) was designed to (1) adapt the coupler geometry to the round window (RW) niche (2) to stabilize the floating mass transducer, and (3) to control static coupling forces to the RW. First audiological outcomes with a custom-made HC2 are reported here. Material and Methods: Ten patients were enrolled in our site-initiated, prospective study. To assess audiological outcomes up to 6 months, preoperative and postoperative hearing thresholds, word recognition score (WRS) at 65 dB SPL and the speech recognition threshold in quiet and noise were performed. The effective gain (EG) and the coupling efficiency were calculated. Results: One revision surgery had to be performed during the study period and a significant, but clinically not relevant bone conduction thresholds change was observed at 4 and 6 kHz at 6-month follow-up. At 6 months, the median WRS (n = 10) improved significantly from 0% to 80%. The median speech reception threshold in noise improved significantly from 11.6 to -2.4 dB SNR, and in quiet significantly from 79.6 to 44.4 dB SPL. The average EG of -1.3 dB indicated a closure of the air bone gap. The determined average coupling efficiency of 23.3 dB was within the acceptance range suggested by the manufacturer. Conclusion: For patients with mixed hearing loss and multiple ear surgeries, the HC2 provided good and stable speech recognition results exceeding published results of RW coupling without a coupler or coupling with the RW soft coupler.

2.
J Phys Condens Matter ; 30(3): 035403, 2018 Jan 24.
Article in English | MEDLINE | ID: mdl-29215347

ABSTRACT

In situ temperature-dependent laser-induced photoluminescence and dielectric measurements provide new evidence for the local occurrence of the α → ß phase transition near 500 K in the preserved crystalline parts of natural radiation-damaged titanite (sample E2335 with ~24% amorphous fraction, containing Fe and Al impurities). Photoluminescence spectroscopic measurements show an anomaly in the vicinity of 500 K. The temperature-dependent evolution of the real part of the electrical conductivity (σ) and the real (ε') and the imaginary (ε″) part of the complex dielectric permittivity (ε *) of titanite have been measured at various AC frequencies (~1.2-96.8 kHz). Despite the masking and smearing effect of impurities and defects, the temperature-dependent behaviour of ε' and ε″ around the transition temperature of the investigated natural titanite E2335 shows a remarkable similarity to that of the synthetic end-member material (see Zhang et al (1995 Phys. Chem. Miner. 22 41-9)). This study indicates the suitability of photoluminescence and impedance spectroscopy for the detection of phase transitions, even in heavily disordered systems.

SELECTION OF CITATIONS
SEARCH DETAIL
...