Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Thorac Surg ; 74(1): 139-42, 2002 Jul.
Article in English | MEDLINE | ID: mdl-12118746

ABSTRACT

BACKGROUND: Comparison of the cytokine generation and leukocyte activation properties of Duroflo II heparin bonded bypass circuit (Baxter Healthcare Corp, Compton, UK) and the conventional cardiopulmonary bypass circuit. Attempt to correlate these to pulmonary dysfunction postoperatively. METHODS: Forty patients undergoing elective, isolated coronary artery bypass grafting were randomly allocated to have either plain extracorporeal circuits (group C) or heparin bonded extracorporeal circuits (group H). Full systemic heparinization was used in all patients. The inflammatory response was assessed by measuring plasma levels of interleukin-6, interleukin-8, interleukin-10, and polymorphonuclear elastase. Gas exchange was assessed by measuring the PaO2/FIO2 ratio. RESULTS: Significant impairment of oxygenation was seen in both groups with the lowest values at the end of the operation before a gradual return to normal during the next 6 hours. There were no differences between the groups in gas exchange or times to extubation. There were significant elevations in all the cytokines, with interleukin-6 levels peaking at 4 hours in group H and 24 hours in group C, before starting to return to normal at 48 hours. The patterns of interleukin-8 and interleukin-10 rise were identical in the two groups. Polymorphonuclear elastase reached a peak at the end of the operation in group H and remained elevated up to 24 hours, whereas levels continued to rise in group C up to 4 hours. There were no significant differences in levels between groups at any time. There were no differences between the groups in blood loss or blood product usage. CONCLUSIONS: Cardiopulmonary bypass induces a systemic inflammatory response with release of cytokines and activation of leukocytes. This correlates with the severe deterioration in pulmonary gas exchange from preoperative levels up to 6 hours postoperatively (p < 0.05). In the presence of systemic heparinization, Duroflo II heparin bondingtf the circuits has minor effects on the pattern of evolution of this inflammatory response.


Subject(s)
Anticoagulants , Cardiopulmonary Bypass , Coated Materials, Biocompatible , Cytokines/metabolism , Extracorporeal Circulation , Heparin , Inflammation Mediators/blood , Pulmonary Gas Exchange , Adult , Aged , Coronary Artery Bypass , Humans , Interleukin-10/blood , Interleukin-6/blood , Interleukin-8/blood , Leukocyte Elastase/blood , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...