Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Infect Prev Pract ; 4(4): 100247, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36573091

ABSTRACT

Background: Transrectal ultrasound (TRUS)-guided prostate biopsy is associated with infection rates between 0.3 % and 3.2%. Infectious complications include urinary tract infection, prostatitis, bacteraemia and sepsis. Surgical site surveillance in this patient cohort is becoming increasingly important given global increases in antimicrobial resistance. Methods: Surgical site surveillance for patients undergoing TRUS biopsies was introduced in our hospital in 2017. All patients had a risk assessment form completed to assess for carriage or risk of carriage of multi-drug resistant organisms. An intense analysis was completed on any patient who developed an infection post-TRUS biopsy. Data was fed back on a quarterly basis to a multi-disciplinary working group. Members of this group include a Consultant Microbiologist, Infection Prevention and Control Nurse, Consultant Urologist, Antimicrobial Pharmacists and Clinical Nurse Ward Managers. Results: 784 TRUS-guided biopsy of the prostate procedures were performed between January 1 st 2017 and the end of the third quarter, 2021. The rate of infection post-TRUS was 2.7% in 2017, 3.4% in 2018 and 3.2% in 2019. This improved to 0% in 2020 and 0.8% in the first three quarters of 2021. Conclusions: Several interventions were introduced resulting in a sustained reduction in infection rates in this cohort. These include changing the choice of surgical antibiotic prophylaxis, improvement in the timing of antibiotic prophylaxis and scheduling of other urology procedures. The introduction of surgical site surveillance and multi-disciplinary input has demonstrated a reduction in infection rates post TRUS biopsy.

2.
J Infect Prev ; 20(4): 164-170, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31428196

ABSTRACT

BACKGROUND: Healthcare-associated infection compromises patient safety. Compliance with hand hygiene (HH) guidelines has been shown to be an effective method of reducing infection; however, it remains suboptimal and poorer among doctors compared to other healthcare workers. The aim of this study is to determine the relationship between an individualised observational hand hygiene audit (OHHA) and feedback intervention with observed HH compliance. METHODS: We used a retrospective interrupted time series design using OHHA data from a five-year period, 2011-2015. OHHA indicated poorer HH compliance among doctors than other healthcare workers in a 345-bed acute private hospital. An increase in orthopaedic surgical site infection prompted additional auditing of the orthopaedic unit further identifying substandard HH compliance among orthopaedic surgeons. In addition to ongoing HH interventions, an individualised hand hygiene audit and feedback intervention focusing on consultant orthopaedic surgeons was implemented. Observed HH compliance improved. The intervention was then extended to include all consultant doctors at the study site. Audit was implemented by trained clinical nurse managers during clinical rounds. Written audit feedback was provided by the infection prevention and control team. RESULTS: HH compliance increased significantly among both orthopaedic surgeons and other consultant doctors, P < 0.05. CONCLUSION: An individualised audit and feedback intervention was effective in improving compliance. Incorporation of OHHA with individualised feedback into routine daily practice needs to be considered as a quality improvement opportunity. This study has the potential to inform other audit and feedback interventions to maximise effectiveness and ensure implementation.

3.
Am J Infect Control ; 47(7): 798-803.e1, 2019 07.
Article in English | MEDLINE | ID: mdl-30711350

ABSTRACT

BACKGROUND: Compliance with hand hygiene guidelines reduces the risk of health care-associated infection, yet doctors are less compliant than other health care workers. Use of observational hand hygiene auditing with targeted individualized feedback was implemented, with improved hand hygiene of consultant doctors; however, the factors that influenced this were not explained by previous quantitative data. The aim was to explore consultant doctors' opinions about the influence of observational hand hygiene auditing with individualized feedback on hand hygiene behavior. METHODS: Using the Theoretical Domains Framework, we conducted 12 semi-structured in-depth interviews with consultant doctors who experienced the observational hand hygiene audit and feedback intervention. Data were analyzed using a thematic analysis approach. RESULTS: Analysis identified 8 domains of the Theoretical Domains Framework, with 5 dominant domains: (1) behavioral regulation: receiving written individualized audit feedback positively influenced practice; (2) knowledge: provision of specific individualized feedback improved performance; (3) reinforcement: audit highlighted substandard practices; (4) social professional role and identity: audit reports triggered profession-associated competitive motivation; and (5) environmental context and resources: auditing was perceived to be synonymous with strong organizational safety culture. CONCLUSIONS: In this study, provision of individualized targeted feedback was a critical component of observational hand hygiene auditing.


Subject(s)
Attitude of Health Personnel , Consultants/psychology , Cross Infection/prevention & control , Hand Hygiene/statistics & numerical data , Health Knowledge, Attitudes, Practice , Physicians/psychology , Feedback , Guideline Adherence/statistics & numerical data , Humans , Physicians/ethics , Practice Guidelines as Topic , Professional Role/psychology , Qualitative Research , Surveys and Questionnaires
4.
J Cardiovasc Transl Res ; 9(3): 239-248, 2016 06.
Article in English | MEDLINE | ID: mdl-27075735

ABSTRACT

Personalised treatment of heart disease requires an understanding of the patient-specific characteristics, which can vary over time. A newly developed implantable surface acoustic wave pressure sensor, capable of continuous monitoring of the left ventricle filling pressure, is a novel device for personalised management of patients with heart disease. However, a one-size-fits-all approach to device sizing will affect its positioning within the pulmonary artery and its relationship to the interrogating device on the chest wall on a patient-specific level. In this paper, we analyse the spatial orientation and morphology of the pulmonary artery and its main branches in patients who could benefit from the device and normal controls. The results could optimise the design of the sensor, its stent, and importantly its placement, ensuring long-term monitoring in patient groups.


Subject(s)
Acoustics/instrumentation , Arterial Pressure , Blood Pressure Monitoring, Ambulatory/instrumentation , Blood Pressure Monitors , Heart Diseases/diagnosis , Hypertension, Pulmonary/diagnosis , Pulmonary Artery/physiopathology , Transducers, Pressure , Ventricular Pressure , Adult , Aged , Case-Control Studies , Computed Tomography Angiography , Equipment Design , Female , Heart Diseases/physiopathology , Humans , Hypertension, Pulmonary/physiopathology , Male , Middle Aged , Multidetector Computed Tomography , Predictive Value of Tests , Pulmonary Artery/diagnostic imaging , Time Factors , Ventricular Function, Left
5.
6.
J Mater Eng Perform ; 23: 2599-2605, 2014.
Article in English | MEDLINE | ID: mdl-25089084

ABSTRACT

The present article presents a method for assessing the radial stiffness of nitinol stents. An idealized stent model was created, and its radial stiffness was calculated by means of finite element modeling. The calculations were validated against experimental measurements. The variation of radial stiffness with geometrical dimensions was calculated, and the effect of increasing radial stiffness on endovascular deployment was analyzed. Peak tensile and compressive stresses as well as stent penetration were calculated in the case of an idealized pulmonary artery model having realistic dimensions as well as stiffness. The results of stress calculations were compared with a second set of simulations, where an idealized behavior of the stent (uniform expansion to a theoretical contact diameter) was modeled. The results show how in reality nitinol stents behave in a non-ideal way, having a non-uniform expansion and exerting non-uniform pressure on the contact areas with the artery. Such non-ideality decreases though with the increase in radial stiffness. The radial force alone may be insufficient in describing the stent-artery interaction, and numerical modeling proves to be necessary for capturing such complexity.

8.
Healthc Technol Lett ; 1(2): 51-5, 2014 Jun.
Article in English | MEDLINE | ID: mdl-26609377

ABSTRACT

The frequency response of an implantable antenna is key to the performance of a wireless implantable sensor. If the antenna detunes significantly, there are substantial power losses resulting in loss of accuracy. One reason for detuning is because of a change in the surrounding environment of an antenna. The pulsating anatomy of the human heart constitutes such a changing environment, so detuning is expected but this has not been quantified dynamically before. Four miniature implantable antennas are presented (two different geometries) along with which are placed within the heart of living swine the dynamic reflection coefficients. These antennas are designed to operate in the short range devices frequency band (863-870 MHz) and are compatible with a deeply implanted cardiovascular pressure sensor. The measurements recorded over 27 seconds capture the effects of the beating heart on the frequency tuning of the implantable antennas. When looked at in the time domain, these effects are clearly physiological and a combination of numerical study and posthumous autopsy proves this to be the case, while retrospective simulation confirms this hypothesis. The impact of pulsating anatomy on antenna design and the need for wideband implantable antennas is highlighted.

9.
Biomed Microdevices ; 15(5): 737-49, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23559403

ABSTRACT

In this paper, the development of a fully implantable wireless sensor able to provide continuous real-time accurate pressure measurements is presented. Surface Acoustic Wave (SAW) technology was used to deposit resonators on crystalline quartz wafers; the wafers were then assembled to produce a pressure sensitive device. Excitation and reading via a miniature antenna attached to the pressure sensor enables continuous external interrogation. The main advantages of such a configuration are the long term stability of quartz and the low power necessary for the interrogation, which allows 24/7 interrogation by means of a hand-held, battery powered device. Such data are of vital importance to clinicians monitoring and treating the effects of hypertension and heart failure. A prototype was designed and tested using both a bio-phantom test rig and an animal model. The pressure traces for both compare very well with a commercially available catheter tip pressure transducer. The work presented in this paper is the first known wireless pressure data from the left ventricle of the heart of a living swine.


Subject(s)
Blood Pressure Determination/instrumentation , Blood Pressure Determination/methods , Prostheses and Implants , Wireless Technology , Animals , Blood Pressure , Equipment Design , Models, Animal , Swine , Transducers, Pressure
10.
Int J Radiat Oncol Biol Phys ; 66(5): 1335-8, 2006 Dec 01.
Article in English | MEDLINE | ID: mdl-17084562

ABSTRACT

PURPOSE: Patients undergoing breast-conserving surgery were offered boost radiotherapy with targeted intraoperative radiotherapy (TARGIT) using the Intrabeam system to test the feasibility, safety, and efficacy of the new approach. METHODS AND MATERIALS: We treated 302 cancers in 301 unselected patients. This was not a low-risk group. One-third of patients (98/301) were younger than 51 years of age. More than half of the tumors (172, 57%) were between 1 cm and 2 cm, and one-fifth (62, 21%) were >2 cm; 29% (86) had a Grade 3 tumor and, in 29% (87), axillary lymph nodes contained metastasis. After primary surgery, 20 Gy was delivered intraoperatively to the surface of the tumor bed, followed by external-beam radiotherapy (EBRT), but excluding the usual boost. RESULTS: The treatment was well tolerated. The follow-up ranged from 3 to 80 months (164 and 90 patients completed 2 and 3 years follow-up, respectively). Four patients (1.3%) had local recurrence. The Kaplan-Meier estimate of local recurrence is 2.6% (SE = 1.7) at 5 years. This compares favorably with the 4.3% recurrence rate in boosted patients from the EORTC boost study, in which only 8.1% patients were node-positive, as opposed to 29% in our series. CONCLUSION: Targeted intraoperative radiotherapy combined with EBRT results in a low local recurrence rate. This could be attributed to both accurate targeting and timeliness of the treatment. These data support the need for a randomized trial to test whether the TARGIT boost is superior to conventional external boost, especially in high-risk women.


Subject(s)
Breast Neoplasms/radiotherapy , Breast Neoplasms/surgery , Adult , Aged , Aged, 80 and over , Breast Neoplasms/pathology , Combined Modality Therapy/methods , Feasibility Studies , Female , Follow-Up Studies , Humans , Intraoperative Period , Mastectomy, Segmental , Middle Aged , Neoplasm Recurrence, Local , Pilot Projects , Radiotherapy/methods , Radiotherapy Dosage
11.
Int J Antimicrob Agents ; 28(4): 273-9, 2006 Oct.
Article in English | MEDLINE | ID: mdl-16973337

ABSTRACT

It is widely believed that reducing antimicrobial usage should reduce resistance, although observational evidence is mixed. Pneumococci make ideal subjects to test this belief as they are widely surveyed and lack an animal reservoir. Accordingly, susceptibility data for pneumococci in the UK and Ireland were retrieved from the Health Protection Agency's LabBase/CoSurv system and from the European Antimicrobial Resistance Surveillance System (EARSS) and British Society for Antimicrobial Chemotherapy (BSAC) databases. The BSAC surveillance examines respiratory pneumococci; the other systems focus upon invasive organisms only, with the LabBase/CoSurv system being the most comprehensive, capturing data on most bacteraemias in England and Wales. National pharmacy sales data were obtained from the IMS Health MIDAS database and were modelled to the resistance data by logistic and linear regression analysis. All systems except for the BSAC respiratory surveillance data indicated that penicillin resistance has fallen significantly since 1999 in the UK, whereas macrolide resistance has been essentially stable, or has risen slightly. The data for Ireland were based on smaller sample sizes but suggested a fall in penicillin non-susceptibility from 1999 to 2004, with conflicting evidence for macrolide resistance. The recent decreasing trend in penicillin resistance is in contrast to a rising trend in England and Wales until (at least) 1997 and strongly rising macrolide resistance from 1989 to 1993. UK pharmacy sales of macrolides and oral beta-lactams fell by ca. 30% in the late 1990s following increased concern about resistance, before stabilising or rising weakly; sales in Ireland were stable or rose slightly in the study period. We conclude that falling penicillin resistance in pneumococci followed reduced sales of oral beta-lactams to pharmacies in the UK, but a similar fall in macrolide sales was not associated with any fall in resistance. Stabilisation or decline in penicillin resistance has occurred in Ireland despite stable or increasing oral beta-lactam sales.


Subject(s)
Anti-Bacterial Agents/administration & dosage , Anti-Bacterial Agents/pharmacology , Drug Resistance, Bacterial , Practice Guidelines as Topic , Streptococcus pneumoniae/drug effects , Anti-Bacterial Agents/pharmacokinetics , Commerce , Drug Resistance, Multiple , Drug Utilization/standards , Drug Utilization/statistics & numerical data , England/epidemiology , Ireland/epidemiology , Macrolides/pharmacology , Macrolides/therapeutic use , Penicillin Resistance , Penicillins/therapeutic use , Pharmacies , Pneumococcal Infections/epidemiology , Pneumococcal Infections/microbiology , Population Surveillance , Streptococcus pneumoniae/isolation & purification , United Kingdom/epidemiology
12.
J Am Coll Cardiol ; 45(4): 573-80, 2005 Feb 15.
Article in English | MEDLINE | ID: mdl-15708706

ABSTRACT

OBJECTIVES: We investigated the long-term efficacy of cryo ablation for treatment of atrial flutter. BACKGROUND: To our knowledge, no study has assessed the long-term efficacy of cryo ablation by assessing both symptom and conduction recurrence. METHODS: A total of 45 consecutive patients with symptomatic atrial flutter were ablated with a 7-F, 6-mm-tip, quadripolar cryo catheter (Freezor Xtra, CryoCath Technologies Inc., Kirkland, Canada). Electrophysiologic studies (EPS) were performed with diagnostic catheters. Cryo ablation was at -75 degrees C for 4 min, beginning at the inferior rim of the coronary sinus os and creating a posterior line to the Eustachian ridge. Safety, bi-directional isthmus block at intervention, and recurrence at three, six, and nine months post procedure were assessed. RESULTS: There were no adverse events reported. All patients were free of discomfort on cryo energy delivery. The acute success rate at intervention was 87%. Follow-up data from 39 acutely successful patients showed 27 (69%) without conduction recurrence on repeat EPS at three months, and none (0%) had symptom recurrence documented by Holter monitoring, electrocardiogram, and/or patient diary records at three, six, and nine months follow-up. CONCLUSIONS: Our experience with a new 7-F, 6-mm-tip, quadripolar cryo catheter yielded a fairly high success rate at intervention, an excellent safety profile, and a good chronic success rate in terms of symptom recurrence. However, further monitoring is necessary to determine whether all asymptomatic patients continue to remain free of symptoms, given the small pool of patients demonstrated to have conduction recurrence.


Subject(s)
Atrial Flutter/surgery , Cardiac Catheterization , Cryosurgery , Aged , Atrial Flutter/physiopathology , Cryosurgery/methods , Electrocardiography , Electrophysiology , Follow-Up Studies , Humans , Middle Aged , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...