Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Talanta ; 271: 125698, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38262128

ABSTRACT

Persistent, mobile and toxic substances have drawn attention nowadays due to their particular properties, but they are overlooked in human monitorization works, limiting the knowledge of the human exposome. In that sense, human urine is an interesting matrix since not only parent compounds are eliminated, but also their phase II metabolites that could act as biomarkers. In this work, 11 sample preparation procedures involving preconcentration were tested to ensure maximum analytical coverage in human urine using mixed-mode liquid chromatography coupled with high-resolution tandem mass spectrometry. The optimized procedure consisted of a combination of solid-phase extraction and salt-assisted liquid-liquid extraction and it was employed for suspect screening. Additionally, a non-discriminatory dilute-and-shoot approach was also evaluated. After evaluating the workflow in terms of limits of identification and type II errors (i.e., false negatives), a pooled urine sample was analysed. From a list of 1450 suspects and in-silico simulated 1568 phase II metabolites (i.e. sulphates, glucuronides, and glycines), 44 and 14 substances were annotated, respectively. Most of the screened suspects were diverse industrial chemicals, but biocides, natural products and pharmaceuticals were also detected. Lastly, the complementarity of the sample preparation procedures, columns, and analysis conditions was assessed. As a result, dilute-and-shoot and the Acclaim Trinity P1 column at pH = 3 (positive ionization) and pH = 7 (negative ionization) allowed the maximum coverage since almost 70 % of the total suspects could be screened using those conditions.


Subject(s)
Body Fluids , Tandem Mass Spectrometry , Humans , Chromatography, High Pressure Liquid/methods , Chromatography, Liquid , Tandem Mass Spectrometry/methods , Specimen Handling , Solid Phase Extraction/methods
2.
Chemosphere ; 351: 141221, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38224745

ABSTRACT

Suspect and non-target screening (SNTS) methods are being promoted in order to decode the human exposome since a wide chemical space can be analysed in a diversity of human biofluids. However, SNTS approaches in the exposomics field are infra-studied in comparison to environmental or food monitoring studies. In this work, a comprehensive suspect screening workflow was developed to annotate exposome-related xenobiotics and phase II metabolites in diverse human biofluids. Precisely, human urine, breast milk, saliva and ovarian follicular fluid were employed as samples and analysed by means of ultra-high performance liquid chromatography coupled with high resolution tandem mass spectrometry (UHPLC-HRMS/MS). To automate the workflow, the "peak rating" parameter implemented in Compound Discoverer 3.3.2 was optimized to avoid time-consuming manual revision of chromatographic peaks. In addition, the presence of endogenous molecules that might interfere with the annotation of xenobiotics was carefully studied as the employment of inclusion and exclusion suspect lists. To evaluate the workflow, limits of identification (LOIs) and type I and II errors (i.e., false positives and negatives, respectively) were calculated in both standard solutions and spiked biofluids using 161 xenobiotics and 22 metabolites. For 80.3 % of the suspects, LOIs below 15 ng/mL were achieved. In terms of type I errors, only two cases were identified in standards and spiked samples. Regarding type II errors, the 7.7 % errors accounted in standards increased to 17.4 % in real samples. Lastly, the use of an inclusion list for endogens was favoured since it avoided 18.7 % of potential type I errors, while the exclusion list caused 7.2 % of type II errors despite making the annotation workflow less time-consuming.


Subject(s)
Exposome , Female , Humans , Xenobiotics/metabolism , Workflow , Chromatography, High Pressure Liquid/methods , Tandem Mass Spectrometry
3.
Chemosphere ; 339: 139690, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37541438

ABSTRACT

The use of suspect and non-target screening (SNTS) for the characterization of the chemical exposome employing human biofluids is gaining attention. Among the biofluids, urine is one of the preferred matrices since organic xenobiotics are excreted through it after metabolization. However, achieving a consensus between selectivity (i.e. preserving as many compounds as possible) and sensitivity (i.e. minimizing matrix effects by removing interferences) at the sample preparation step is challenging. Within this context, several sample preparation approaches, including solid-phase extraction (SPE), liquid-liquid extraction (LLE), salt-assisted LLE (SALLE) and dilute-and-shoot (DS) were tested to screen not only exogenous compounds in human urine but also their phase II metabolites using liquid-chromatography coupled to high-resolution tandem mass spectrometry (LC-HRMS/MS). Additionally, enzymatic hydrolysis of phase II metabolites was evaluated. Under optimal conditions, SPE resulted in the best sample preparation approach in terms of the number of detected xenobiotics and metabolites since 97.1% of the total annotated suspects were present in samples extracted by SPE. In LLE and SALLE, pure ethyl acetate turned out to be the best extractant but fewer suspects than with SPE (80.7%) were screened. Lastly, only 52.5% of the suspects were annotated in the DS approach, showing that it could only be used to detect compounds at high concentration levels. Using pure standards, the presence of diverse xenobiotics such as parabens, industrial chemicals (benzophenone-3, caprolactam and mono-2-ethyl-5-hydroxyhexyl phthalate) and chemicals related to daily habits (caffeine, cotinine or triclosan) was confirmed. Regarding enzymatic hydrolysis, only 10 parent compounds of the 44 glucuronides were successfully annotated in the hydrolysed samples. Therefore, the screening of metabolites in non-hydrolysed samples through SNTS is the most suitable approach for exposome characterization.


Subject(s)
Exposome , Xenobiotics , Humans , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Solid Phase Extraction/methods
4.
J Chromatogr A ; 1705: 464141, 2023 Aug 30.
Article in English | MEDLINE | ID: mdl-37364523

ABSTRACT

In this work, a comprehensive method for the simultaneous determination of 33 diverse persistent and mobile organic compounds (PMOCs) in human urine was developed by dilute-and-shoot (DS) followed by mixed-mode liquid chromatography coupled with tandem mass spectrometry (MMLC-MS/MS). In the sample preparation step, DS was chosen since it allowed the quantification of all targets in comparison to lyophilization. For the chromatographic separation, Acclaim Trinity P1 and P2 trimodal columns provided greater capacity for retaining PMOCs than reverse phase and hydrophilic interaction liquid chromatography. Therefore, DS was validated at 5 and 50 ng/mL in urine with both mixed mode columns at pH = 3 and 7. Regarding figures of merit, linear calibration curves (r2 > 0.999) built between instrumental quantification limits (mostly below 5 ng/mL) and 500 ng/mL were achieved. Despite only 60% of the targets were recovered at 5 ng/mL because of the dilution, all PMOCs were quantified at 50 ng/mL. Using surrogate correction, apparent recoveries in the 70-130% range were obtained for 91% of the targets. To analyse human urine samples, the Acclaim Trinity P1 column at pH = 3 and 7 was selected as a consensus between analytical coverage (i.e. 94% of the targets) and chromatographic runs. In a pooled urine sample, industrial chemicals (acrylamide and bisphenol S), biocides and their metabolites (2-methyl-4-isothiazolin-3-one, dimethyl phosphate, 6-chloropyridine-3-carboxylic acid, and ammonium glufosinate) and an artificial sweetener (aspartame) were determined at ng/mL levels. The outcomes of this work showed that humans are also exposed to PMOCs due to their persistence and mobility, and therefore, further human risk assessment is needed.


Subject(s)
Urinalysis , Limit of Detection , Urinalysis/methods , Tandem Mass Spectrometry/methods , Humans , Chromatography, High Pressure Liquid/methods
5.
Anal Bioanal Chem ; 414(23): 6855-6869, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35904524

ABSTRACT

In the present work, a target analysis method for simultaneously determining 24 diverse endocrine-disrupting compounds (EDCs) in urine (benzophenones, bisphenols, parabens, phthalates and antibacterials) was developed. The target analysis approach (including enzymatic hydrolysis, clean-up by solid-phase extraction and analysis by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS)) was optimized, validated and applied to volunteers' samples, in which 67% of the target EDCs were quantified. For instance, benzophenone-3 (0.2-13 ng g-1), bisphenol A (7.7-13.7 ng g-1), methyl 3,5-dihydroxybenzoate (8-254 ng g-1), mono butyl phthalate (2-17 ng g-1) and triclosan (0.3-9 ng g-1) were found at the highest concentrations, but the presence of other analogues was detected as well. The developed target method was further extended to suspect and non-target screening (SNTS) by means of LC coupled to high-resolution MS/MS. First, well-defined workflows for SNTS were validated by applying the previously developed method to an extended list of compounds (83), and then, to the same real urine samples. From a list of approximately 4000 suspects, 33 were annotated at levels from 1 to 3, with food additives/ingredients and personal care products being the most abundant ones. In the non-target approach, the search was limited to molecules containing S, Cl and/or Br atoms, annotating 4 pharmaceuticals. The results from this study showed that the combination of the lower limits of detection of MS/MS and the identification power of high-resolution MS/MS is still compulsory for a more accurate definition of human exposome in urine samples.


Subject(s)
Endocrine Disruptors , Tandem Mass Spectrometry , Benzhydryl Compounds/analysis , Chromatography, Liquid/methods , Endocrine Disruptors/analysis , Humans , Parabens/analysis , Solid Phase Extraction , Tandem Mass Spectrometry/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...