Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Cardiovasc Electrophysiol ; 35(1): 78-85, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37942843

ABSTRACT

INTRODUCTION: Atrio-esophageal fistula after esophageal thermal injury (ETI) is one of the most devastating complications of available energy sources for atrial fibrillation (AF) ablation. Pulsed field ablation (PFA) uses electroporation as a new energy source for catheter ablation with promising periprocedural safety advantages over existing methods due to its unique myocardial tissue sensitivity. In preclinical animal studies, a dose-dependent esophageal temperature rise has been reported. In the TESO-PFA registry intraluminal esophageal temperature (TESO) changes in a clinical setting are evaluated. METHODS: Consecutive symptomatic AF patients (62 years, 67% male, 61% paroxysmal AF, CHA2 DS2 Vasc Score 2) underwent first-time PFA and were prospectively enrolled into our registry. Eight pulse trains (2 kV/2.5 s, bipolar, biphasic, x4 basket/flower configuration each) were delivered to each pulmonary vein (PV). Two extra pulse trains per PV in flower configuration were added for wide antral circumferential ablation. Continuous intraluminal esophageal temperature (TESO) was monitored with a 12-pole temperature probe. RESULTS: Median TESO change was statistically significant and increased by 0.8 ± 0.6°C, p < .001. A TESO increase ≥ 1°C was observed in 10/43 (23%) patients. The highest TESO measured was 40.3°C. The largest TESO difference (∆TESO) was 3.7°C. All patients remained asymptomatic considering possible ETI. No atrio-esophageal fistula was reported on follow-up. CONCLUSION: A small but significant intraluminal esophageal temperature rise can be observed in most patients during PFA. TESO rise over 40°C is rare. The clinical implications of the observed findings need to be further evaluated.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophageal Fistula , Pulmonary Veins , Animals , Humans , Male , Female , Temperature , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Heart Rate , Esophageal Fistula/diagnosis , Esophageal Fistula/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Pulmonary Veins/surgery , Treatment Outcome
2.
Front Cardiovasc Med ; 10: 1217745, 2023.
Article in English | MEDLINE | ID: mdl-37435050

ABSTRACT

Background: Wide antral circumferential ablation (WACA) in comparison to ostial pulmonary vein (PV) isolation (PVI) has been attributed with improved rhythm outcome. We investigated the feasibility, lesion formation, and rhythm outcome of WACA-PVI in comparison to ostial-PVI using pulsed field ablation (PFA). Methods: Symptomatic atrial fibrillation (AF) patients (69 years, 67% male; 67% paroxysmal AF) were prospectively enrolled into our single-center registry and underwent first-time ostial-PFA or WACA-PFA, N = 15 each. In all patients, eight pulse trains (2 kV/2.5 s, bipolar, biphasic, 4× basket/flower configuration each) were delivered to each PV. In WACA-PFA, two extra pulse trains in a flower configuration were added to the anterior and posterior antrum of the PVs. For comparison of PFA lesion size, pre- and post-ablation left atrial (LA) voltage maps were acquired using a multipolar spiral catheter together with a three-dimensional electroanatomic mapping system. Results: WACA-PFA resulted in a significant larger lesion formation than ostial-PFA (45.5 vs. 35.1 cm2, p = 0.001) with bilateral overlapping butterfly shape-like lesions and concomitant posterior LA wall isolation in 73% of patients. This was not associated with increased procedure time, sedation dosage, or exposure to radiation. One-year freedom from AF recurrence was numerically higher after WACA-PFA than ostial-PFA (94% vs. 87%) but not statistically significant (p = 0.68). No organized atrial tachycardias (ATs) were observed. Ostial-PFA patients more often underwent re-ablation due to recurrent AF episodes. Conclusion: WACA-PFA is feasible and resulted in significantly wider lesion sets than ostial-PFA. Concomitant posterior LA wall isolation occurred as an epiphenomenon in the majority of patients. The WACA approach was associated with neither increased procedure and fluoroscopy times nor statistically significant differences in 1-year rhythm outcome. ATs were absent.

SELECTION OF CITATIONS
SEARCH DETAIL
...