1.
Otol Neurotol ; 45(7): e517-e524, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38918070

ABSTRACT

HYPOTHESES: In newly implanted cochlear implant (CI) users, electrically evoked compound action (eCAPs) and electrocochleography (ECochGs) will remain stable over time. Electrode impedances will increase immediately postimplantation due to the initial inflammatory response, before decreasing after CI switch-on and stabilizing thereafter. BACKGROUND: The study of cochlear health (CH) has several applications, including explaining variation in CI outcomes, informing CI programming strategies, and evaluating the safety and efficacy of novel biological treatments for hearing loss. Very early postoperative CH patterns have not previously been intensively explored through longitudinal daily testing. Thanks to technological advances, electrode impedances, eCAPs, and ECochGs can be independently performed by CI users at home to monitor CH over time. METHODS: A group of newly implanted CI users performed daily impedances, eCAPs, and ECochGs for 3 months at home, starting from the first day postsurgery (N = 7) using the Active Insertion Monitoring system by Advanced Bionics. RESULTS: Measurement validity of 93.5, 93.0, and 81.6% for impedances, eCAPs, and ECochGs, respectively, revealed high participant compliance. Impedances increased postsurgery before dropping and stabilizing after switch-on. eCAPs showed good stability, though statistical analyses revealed a very small but significant increase in thresholds over time. Most ECochG thresholds did not reach the liberal signal-to-noise criterion of 2:1, with low threshold stability over time. CONCLUSION: Newly implanted CI recipients can confidently and successfully perform CH recordings at home, highlighting the valuable role of patients in longitudinal data collection. Electrode impedances and eCAPs are promising objective measurements for evaluating CH in newly implanted CI users.


Subject(s)
Audiometry, Evoked Response , Cochlear Implantation , Cochlear Implants , Electric Impedance , Humans , Cochlear Implantation/methods , Audiometry, Evoked Response/methods , Middle Aged , Female , Male , Aged , Adult , Cochlea/physiopathology , Cochlea/surgery , Postoperative Period , Evoked Potentials, Auditory/physiology , Action Potentials/physiology
2.
Front Neurol ; 13: 1042408, 2022.
Article in English | MEDLINE | ID: mdl-36468071

ABSTRACT

Recent technological advances in cochlear implant (CI) telemetry have enabled, for the first time, CI users to perform cochlear health (CH) measurements through self-assessment for prolonged periods of time. This is important to better understand the influence of CH on CI outcomes, and to assess the safety and efficacy of future novel treatments for deafness that will be administered as adjunctive therapies to cochlear implantation. We evaluated the feasibility of using a CI to assess CH and examined patterns of electrode impedances, electrically-evoked compound action potentials (eCAPs) and electrocochleography (ECochGs), over time, in a group of adult CI recipients. Fifteen subjects were trained to use the Active Insertion Monitoring tablet by Advanced Bionics, at home for 12 weeks to independently record impedances twice daily, eCAPs once weekly and ECochGs daily in the first week, and weekly thereafter. Participants also completed behavioral hearing and speech assessments. Group level measurement compliance was 98.9% for impedances, 100% for eCAPs and 99.6% for ECochGs. Electrode impedances remained stable over time, with only minimal variation observed. Morning impedances were significantly higher than evening measurements, and impedances increased toward the base of the cochlea. eCAP thresholds were also highly repeatable, with all subjects showing 100% measurement consistency at, at least one electrode. Just over half of all subjects showed consistently absent thresholds at one or more electrodes, potentially suggesting the existence of cochlear dead regions. All subjects met UK NICE guidelines for cochlear implantation, so were expected to have little residual hearing. ECochG thresholds were, unsurprisingly, highly erratic and did not correlate with audiometric thresholds, though lower ECochG thresholds showed more repeatability over time than higher thresholds. We conclude that it is feasible for CI users to independently record CH measurements using their CI, and electrode impedances and eCAPs are promising measurements for objectively assessing CH.

3.
J Assoc Res Otolaryngol ; 22(6): 703-717, 2021 12.
Article in English | MEDLINE | ID: mdl-34581879

ABSTRACT

Whilst functional neuroimaging has been used to investigate cortical processing of degraded speech in adults, much less is known about how these signals are processed in children. An enhanced understanding of cortical correlates of poor speech perception in children would be highly valuable to oral communication applications, including hearing devices. We utilised vocoded speech stimuli to investigate brain responses to degraded speech in 29 normally hearing children aged 6-12 years. Intelligibility of the speech stimuli was altered in two ways by (i) reducing the number of spectral channels and (ii) reducing the amplitude modulation depth of the signal. A total of five different noise-vocoded conditions (with zero, partial or high intelligibility) were presented in an event-related format whilst participants underwent functional near-infrared spectroscopy (fNIRS) neuroimaging. Participants completed a word recognition task during imaging, as well as a separate behavioural speech perception assessment. fNIRS recordings revealed statistically significant sensitivity to stimulus intelligibility across several brain regions. More intelligible stimuli elicited stronger responses in temporal regions, predominantly within the left hemisphere, while right inferior parietal regions showed an opposite, negative relationship. Although there was some evidence that partially intelligible stimuli elicited the strongest responses in the left inferior frontal cortex, a region previous studies have suggested is associated with effortful listening in adults, this effect did not reach statistical significance. These results further our understanding of cortical mechanisms underlying successful speech perception in children. Furthermore, fNIRS holds promise as a clinical technique to help assess speech intelligibility in paediatric populations.


Subject(s)
Auditory Perception , Spectroscopy, Near-Infrared/methods , Speech Intelligibility , Speech Perception , Acoustic Stimulation/methods , Auditory Perception/physiology , Child , Female , Hearing/physiology , Humans , Language , Male , Neuroimaging , Noise , Speech Perception/physiology
4.
Front Hum Neurosci ; 14: 308, 2020.
Article in English | MEDLINE | ID: mdl-32922273

ABSTRACT

Cochlear implants (CIs) are the most successful treatment for severe-to-profound deafness in children. However, speech outcomes with a CI often lag behind those of normally-hearing children. Some authors have attributed these deficits to the takeover of the auditory temporal cortex by vision following deafness, which has prompted some clinicians to discourage the rehabilitation of pediatric CI recipients using visual speech. We studied this cross-modal activity in the temporal cortex, along with responses to auditory speech and non-speech stimuli, in experienced CI users and normally-hearing controls of school-age, using functional near-infrared spectroscopy. Strikingly, CI users displayed significantly greater cortical responses to visual speech, compared with controls. Importantly, in the same regions, the processing of auditory speech, compared with non-speech stimuli, did not significantly differ between the groups. This suggests that visual and auditory speech are processed synergistically in the temporal cortex of children with CIs, and they should be encouraged, rather than discouraged, to use visual speech.

5.
PLoS One ; 14(7): e0219927, 2019.
Article in English | MEDLINE | ID: mdl-31314802

ABSTRACT

Evidence using well-established imaging techniques, such as functional magnetic resonance imaging and electrocorticography, suggest that speech-specific cortical responses can be functionally localised by contrasting speech responses with an auditory baseline stimulus, such as time-reversed (TR) speech or signal-correlated noise (SCN). Furthermore, these studies suggest that SCN is a more effective baseline than TR speech. Functional near-infrared spectroscopy (fNIRS) is a relatively novel, optically-based imaging technique with features that make it ideal for investigating speech and language function in paediatric populations. However, it is not known which baseline is best at isolating speech activation when imaging using fNIRS. We presented normal speech, TR speech and SCN in an event-related format to 25 normally-hearing children aged 6-12 years. Brain activity was measured across frontal and temporal brain areas in both cerebral hemispheres whilst children passively listened to the auditory stimuli. In all three conditions, significant activation was observed bilaterally in channels targeting superior temporal regions when stimuli were contrasted against silence. Unlike previous findings in infants, we found no significant activation in the region of interest over superior temporal cortex in school-age children when normal speech was contrasted against either TR speech or SCN. Although no statistically significant lateralisation effects were observed in the region of interest, a left-sided channel targeting posterior temporal regions showed significant activity in response to normal speech only, and was investigated further. Significantly greater activation was observed in this left posterior channel compared to the corresponding channel on the right side under the normal speech vs SCN contrast only. Our findings suggest that neither TR speech nor SCN are suitable auditory baselines for functionally isolating speech-specific processing in an experimental set up involving fNIRS with 6-12 year old children.


Subject(s)
Brain Mapping , Magnetic Resonance Imaging , Speech Perception , Acoustic Stimulation , Algorithms , Analysis of Variance , Brain Mapping/methods , Child , Electrocorticography , Electronic Data Processing , Female , Humans , Male , Models, Biological
6.
Article in English | MEDLINE | ID: mdl-28825508

ABSTRACT

Older adults have difficulty recalling specific autobiographical events. This over-general memory style is a vulnerability factor for depression. Two groups receiving interventions that have previously been successful at reducing over-general memory in depressed populations were compared to a control group. Participants were healthy older adults aged ≥70 years: memory specificity training (MEST; n = 22), life review (n = 22), and control group (n = 22). There were significant improvements in autobiographical memory specificity in the MEST and life review groups at post-training, relative to the control group, suggesting that over-general memory can be reduced in older adults. Change in social problem solving ability and functional limitations were related to change in autobiographical memory specificity, supporting the suggested role of specific retrieval in generating solutions to social problems and maintaining independence. Qualitative analysis of participants' feedback revealed that life review may be more appropriate for older adults, possibly because it involves integrating specific memories into a positive narrative.


Subject(s)
Affect , Aging/psychology , Learning , Memory, Episodic , Problem Solving , Social Behavior , Aged , Executive Function , Feedback , Female , Humans , Male , Mental Recall , Personal Satisfaction