Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
2.
Bioanalysis ; 10(22): 1781-1801, 2018 Nov 01.
Article in English | MEDLINE | ID: mdl-30488725

ABSTRACT

The 2018 12th Workshop on Recent Issues in Bioanalysis (12th WRIB) took place in Philadelphia, PA, USA on April 9-13, 2018 with an attendance of over 900 representatives from pharmaceutical/biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. WRIB was once again a 5-day full immersion in bioanalysis, biomarkers and immunogenicity. As usual, it was specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest including both small- and large-molecule bioanalysis involving LC-MS, hybrid ligand binding assay (LBA)/LC-MS and LBA/cell-based assays approaches. This 2018 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2018 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 1) covers the recommendations for LC-MS for small molecules, peptides, oligonucleotides and small molecule biomarkers. Part 2 (hybrid LBA/LC-MS for biotherapeutics and regulatory agencies' inputs) and Part 3 (large molecule bioanalysis, biomarkers and immunogenicity using LBA and cell-based assays) are published in volume 10 of Bioanalysis, issues 23 and 24 (2018), respectively.


Subject(s)
Biomarkers/analysis , Oligonucleotides/analysis , Peptides/analysis , Animals , Chromatography, Liquid , Humans , Mass Spectrometry , Philadelphia
3.
Bioanalysis ; 9(22): 1807-1825, 2017 Nov.
Article in English | MEDLINE | ID: mdl-29148835

ABSTRACT

The 2017 11th Workshop on Recent Issues in Bioanalysis (11th WRIB) took place in Los Angeles/Universal City, California from 3 April 2017 to 7 April 2017 with participation of close to 750 professionals from pharmaceutical/biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. WRIB was once again a 5-day, weeklong event - A Full Immersion Week of Bioanalysis, Biomarkers and Immunogenicity. As usual, it was specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest including both small and large molecule analysis involving LCMS, hybrid LBA/LCMS and ligand-binding assay (LBA) approaches. This 2017 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2017 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 1) covers the recommendations for Small Molecules, Peptides and Small Molecule Biomarkers using LCMS. Part 2 (Biotherapeutics, Biomarkers and Immunogenicity Assays using Hybrid LBA/LCMS and Regulatory Agencies' Inputs) and Part 3 (LBA: Immunogenicity, Biomarkers and PK Assays) are published in volume 9 of Bioanalysis, issues 23 and 24 (2017), respectively.


Subject(s)
Biomarkers/analysis , Chromatography, High Pressure Liquid , Mass Spectrometry , Peptides/analysis , Small Molecule Libraries/analysis , Consensus Development Conferences as Topic , Guidelines as Topic , Ligands , Small Molecule Libraries/chemistry
4.
Bioanalysis ; 8(22): 2363-2378, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27712081

ABSTRACT

The 2016 10th Workshop on Recent Issues in Bioanalysis (10th WRIB) took place in Orlando, Florida with participation of close to 700 professionals from pharmaceutical/biopharmaceutical companies, biotechnology companies, contract research organizations, and regulatory agencies worldwide. WRIB was once again a 5-day, weeklong event - A Full Immersion Week of Bioanalysis including Biomarkers and Immunogenicity. As usual, it was specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest including both small and large molecule analysis involving LCMS, hybrid LBA/LCMS, and LBA approaches, with the focus on biomarkers and immunogenicity. This 2016 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. This white paper is published in 3 parts due to length. This part (Part 1) discusses the recommendations for small molecules, peptides and small molecule biomarkers by LCMS. Part 2 (Hybrid LBA/LCMS and regulatory inputs from major global health authorities) and Part 3 (large molecule bioanalysis using LBA, biomarkers and immunogenicity) will be published in the Bioanalysis journal, issue 23.

5.
Article in English | MEDLINE | ID: mdl-25617753

ABSTRACT

The current approach in regulated LC-MS bioanalysis, which evaluates the precision and trueness of an assay separately, has long been criticized for inadequate balancing of lab-customer risks. Accordingly, different total error approaches have been proposed. The aims of this research were to evaluate the aforementioned risks in reality and the difference among four common total error approaches (ß-expectation, ß-content, uncertainty, and risk profile) through retrospective analysis of regulated LC-MS projects. Twenty-eight projects (14 validations and 14 productions) were randomly selected from two GLP bioanalytical laboratories, which represent a wide variety of assays. The results show that the risk of accepting unacceptable batches did exist with the current approach (9% and 4% of the evaluated QC levels failed for validation and production, respectively). The fact that the risk was not wide-spread was only because the precision and bias of modern LC-MS assays are usually much better than the minimum regulatory requirements. Despite minor differences in magnitude, very similar accuracy profiles and/or conclusions were obtained from the four different total error approaches. High correlation was even observed in the width of bias intervals. For example, the mean width of SFSTP's ß-expectation is 1.10-fold (CV=7.6%) of that of Saffaj-Ihssane's uncertainty approach, while the latter is 1.13-fold (CV=6.0%) of that of Hoffman-Kringle's ß-content approach. To conclude, the risk of accepting unacceptable batches was real with the current approach, suggesting that total error approaches should be used instead. Moreover, any of the four total error approaches may be used because of their overall similarity. Lastly, the difficulties/obstacles associated with the application of total error approaches in routine analysis and their desirable future improvements are discussed.


Subject(s)
Chromatography, Liquid/methods , Mass Spectrometry/methods , Biological Assay , Humans , Molecular Weight , Quality Control , Reproducibility of Results , Retrospective Studies
6.
Bioanalysis ; 6(23): 3237-49, 2014.
Article in English | MEDLINE | ID: mdl-25529890

ABSTRACT

The 2014 8th Workshop on Recent Issues in Bioanalysis (8th WRIB), a 5-day full immersion in the evolving field of bioanalysis, took place in Universal City, California, USA. Close to 500 professionals from pharmaceutical and biopharmaceutical companies, contract research organizations and regulatory agencies worldwide convened to share, review, discuss and agree on approaches to address current issues of interest in bioanalysis. The topics covered included both small and large molecules, and involved LCMS, hybrid LBA/LCMS, LBA approaches and immunogenicity. From the prolific discussions held during the workshop, specific recommendations are presented in this 2014 White Paper. As with the previous years' editions, this paper acts as a practical tool to help the bioanalytical community continue advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2014 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 2) covers the recommendations for Hybrid LBA/LCMS, Electronic Laboratory Notebook and Regulatory Agencies' Input. Part 1 (Small molecules bioanalysis using LCMS) was published in the Bioanalysis issue 6(22) and Part 3 (Large molecules bioanalysis using LBA and Immunogenicity) will be published in the Bioanalysis issue 6(24).


Subject(s)
Clinical Laboratory Techniques , Analytic Sample Preparation Methods , Chromatography, Liquid , Humans , Mass Spectrometry
7.
Bioanalysis ; 6(22): 3039-49, 2014.
Article in English | MEDLINE | ID: mdl-25496256

ABSTRACT

The 2014 8th Workshop on Recent Issues in Bioanalysis (8th WRIB), a 5-day full immersion in the evolving field of bioanalysis, took place in Universal City, California, USA. Close to 500 professionals from pharmaceutical and biopharmaceutical companies, contract research organizations and regulatory agencies worldwide convened to share, review, discuss and agree on approaches to address current issues of interest in bioanalysis. The topics covered included both small and large molecules, and involved LCMS, hybrid LBA/LCMS, LBA approaches and immunogenicity. From the prolific discussions held during the workshop, specific recommendations are presented in this 2014 White Paper. As with the previous years' editions, this paper acts as a practical tool to help the bioanalytical community continue advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2014 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 1) covers the recommendations for small molecule bioanalysis using LCMS. Part 2 (Hybrid LBA/LCMS, Electronic Laboratory Notebook and Regulatory Agencies' input) and Part 3 (Large molecules bioanalysis using LBA and Immunogenicity) will be published in the upcoming issues of Bioanalysis.


Subject(s)
Biological Assay , Chromatography, Liquid/methods , Mass Spectrometry/methods
8.
Bioanalysis ; 5(23): 2903-18, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24107004

ABSTRACT

The 2013 7th Workshop on Recent Issues in Bioanalysis was held in Long Beach, California, USA, where close to 500 professionals from pharmaceutical and biopharmaceutical companies, CROs and regulatory agencies convened to discuss current topics of interest in bioanalysis. These 'hot' topics, which covered both small and large molecules, were the starting point for fruitful exchanges of knowledge, and sharing of ideas among speakers, panelists and attendees. The discussions led to specific recommendations pertinent to bioanalytical science. Such as the previous editions, this 2013 White Paper addresses important bioanalytical issues and provides practical answers to the topics presented, discussed and agreed upon by the global bioanalytical community attending the 7th Workshop on Recent Issues in Bioanalysis.


Subject(s)
Drug Discovery/methods , Animals , Biochemistry/methods , Biochemistry/standards , Biomarkers, Pharmacological/analysis , California , Chemistry Techniques, Analytical/methods , Chemistry Techniques, Analytical/standards , Drug Approval/methods , Drug Discovery/standards , Humans , Pharmacokinetics , Validation Studies as Topic
9.
Article in English | MEDLINE | ID: mdl-23917407

ABSTRACT

Linear calibration is usually performed using eight to ten calibration concentration levels in regulated LC-MS bioanalysis because a minimum of six are specified in regulatory guidelines. However, we have previously reported that two-concentration linear calibration is as reliable as or even better than using multiple concentrations. The purpose of this research is to compare two-concentration with multiple-concentration linear calibration through retrospective data analysis of multiple bioanalytical projects that were conducted in an independent regulated bioanalytical laboratory. A total of 12 bioanalytical projects were randomly selected: two validations and two studies for each of the three most commonly used types of sample extraction methods (protein precipitation, liquid-liquid extraction, solid-phase extraction). When the existing data were retrospectively linearly regressed using only the lowest and the highest concentration levels, no extra batch failure/QC rejection was observed and the differences in accuracy and precision between the original multi-concentration regression and the new two-concentration linear regression are negligible. Specifically, the differences in overall mean apparent bias (square root of mean individual bias squares) are within the ranges of -0.3% to 0.7% and 0.1-0.7% for the validations and studies, respectively. The differences in mean QC concentrations are within the ranges of -0.6% to 1.8% and -0.8% to 2.5% for the validations and studies, respectively. The differences in %CV are within the ranges of -0.7% to 0.9% and -0.3% to 0.6% for the validations and studies, respectively. The average differences in study sample concentrations are within the range of -0.8% to 2.3%. With two-concentration linear regression, an average of 13% of time and cost could have been saved for each batch together with 53% of saving in the lead-in for each project (the preparation of working standard solutions, spiking, and aliquoting). Furthermore, examples are given as how to evaluate the linearity over the entire concentration range when only two concentration levels are used for linear regression. To conclude, two-concentration linear regression is accurate and robust enough for routine use in regulated LC-MS bioanalysis and it significantly saves time and cost as well.


Subject(s)
Chromatography, Liquid/standards , Mass Spectrometry/standards , Pharmaceutical Preparations/blood , Calibration , Chromatography, Liquid/methods , Humans , Linear Models , Mass Spectrometry/methods , Retrospective Studies
10.
J Chromatogr B Analyt Technol Biomed Life Sci ; 877(29): 3673-80, 2009 Nov 01.
Article in English | MEDLINE | ID: mdl-19782651

ABSTRACT

A new method development and validation approach is proposed in order to develop a reliable method for the simultaneous quantitation of ramipril and ramiprilat in the presence of numerous labile metabolites. This new approach involves the usage of a synthesized labile acyl glucuronide of ramipril as well as individual and pooled incurred (study) samples in the development and validation process. Following the method validation and prior to its application to a large clinical study, a mini pilot study was performed to evaluate the performance of the method. When the samples from the mini pilot study were analyzed by two different scientists, 100% of the results from incurred sample reanalysis (ISR) matched within 8% of difference and the mean differences were 0.21% and 1.40% for ramipril and ramiprilat, respectively. The validated concentration range reported in this article is 0.2-80 ng/mL for both analytes. Various stabilities, such as bench-top, autosampler, freeze/thaw, and long-term, were also successfully evaluated. The key to the success were low sample processing temperature (4 degrees C), proper choice of sample extraction procedure, and adequate chromatographic conditions to obtain good peak shape without the need of derivatization and baseline separation between the analytes and their glucuronide metabolites.


Subject(s)
Chromatography, Liquid/methods , Ramipril/analogs & derivatives , Ramipril/blood , Tandem Mass Spectrometry/methods , Humans
11.
J Chromatogr B Analyt Technol Biomed Life Sci ; 877(27): 3201-9, 2009 Oct 01.
Article in English | MEDLINE | ID: mdl-19733134

ABSTRACT

Internal standard (IS) responses can directly impact the accuracy of reported concentrations in bioanalysis as the majority of LC-MS/MS methods are based on analyte/IS response ratios for quantitation. Due to the complexity of incurred sample matrices and drug formulation, variable IS responses are quite common upon applying a validated method to the analysis of incurred samples. To maintain the integrity of a study and to avoid economic losses, it is therefore extremely important to monitor IS response variations during bioanalysis and to quickly identify the root causes if variations are observed. Presented in this article are twelve trouble-shooting examples from the analyses of incurred samples by a wide variety of bioanalytical methods, including human error, malfunctioning equipment/instruments, wrong material, matrix effect and inherent issues with a bioanalytical method. Insightful ideas for how to trouble-shoot and how to develop more reliable bioanalytical methods can be drawn from these practical examples.


Subject(s)
Chromatography, Liquid/standards , Tandem Mass Spectrometry/standards , Calibration/standards , Quality Control , Reference Standards , Reproducibility of Results