Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 225
Filter
1.
Front Cardiovasc Med ; 11: 1356010, 2024.
Article in English | MEDLINE | ID: mdl-38725831

ABSTRACT

Hutchinson-Gilford Progeria Syndrome (HGPS) is an ultra-rare genetic premature aging disease that is historically fatal in teenage years, secondary to severe accelerated atherosclerosis. The only approved treatment is the farnesyltransferase inhibitor lonafarnib, which improves vascular structure and function, extending average untreated lifespan of 14.5 years by 4.3 years (30%). With this longer lifespan, calcific aortic stenosis (AS) was identified as an emerging critical risk factor for cardiac death in older patients. Intervention to relieve critical AS has the potential for immediate improvement in healthspan and lifespan. However, HGPS patient-device size mismatch, pervasive peripheral arterial disease, skin and bone abnormalities, and lifelong failure to thrive present unique challenges to intervention. An international group of experts in HGPS, pediatric and adult cardiology, cardiac surgery, and pediatric critical care convened to identify strategies for successful treatment. Candidate procedures were evaluated by in-depth examination of 4 cases that typify HGPS clinical pathology. Modified transcatheter aortic valve replacement (TAVR) and left ventricular Apico-Aortic Conduit (AAC) placement were deemed high risk but viable options. Two cases received TAVR and 2 received AAC post-summit. Three were successful and 1 patient died perioperatively due to cardiovascular disease severity, highlighting the importance of intervention timing and comparative risk stratification. These breakthrough interventions for treating critical aortic stenosis in HGPS patients could rewrite the current clinical perspective on disease course by greatly improving late-stage quality of life and increasing lifespan. Expanding worldwide medical and surgical competency for this ultra-rare disease through expert information-sharing could have high impact on treatment success.

2.
J Cardiovasc Med (Hagerstown) ; 25(3): 210-217, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38251434

ABSTRACT

AIMS: Septal myectomy is the treatment of choice for hypertrophic obstructive cardiomyopathy (HOCM). Around 30-60% of patients with HOCM have a secondary mitral valve regurgitation due to systolic anterior motion (SAM). We report our experience with extended septal myectomy and its impact on the incidence of concomitant mitral valve procedures. METHODS: This is a retrospective study on 84 patients who underwent SM from January 2008 to February 2022. Surgical procedure was performed according to the concept of 'extended myectomy' described by Messmer in 1994. Follow-up outcomes in terms of survival, hospital admissions for heart failure or MV disease, cardiac reoperations, and pacemaker (PMK) implantation were recorded. RESULTS: Mean age was 61 ±â€Š15 years. Mitral valve surgery was performed in seven cases (8%); particularly only one patient without degenerative mitral valve disease underwent mitral valve surgery, with a plicature of the posterior leaflet. In-hospital mortality was 5%. Mitral valve regurgitation greater than mild was present in four patients (5%) at discharge. Twelve-year survival was 78 ±â€Š22%. Cumulative incidence of rehospitalization for heart failure and rehospitalization for mitral valve disease was 10 ±â€Š4 and 2.5 ±â€Š2.5%, respectively. PMK implantation was 5% at discharge, with a cumulative incidence of 15 ±â€Š7%. Freedom from cardiac reoperations was 100%. CONCLUSION: Septal myectomy for HOCM is associated with good outcomes. Although concomitant surgery on the mitral valve to address SAM and associated regurgitation has been advocated, these procedures were needed in our practice only in patients with intrinsic mitral valve disease. Adequate myectomy addresses the underlying pathophysiology in most patients.


Subject(s)
Cardiomyopathy, Hypertrophic , Heart Failure , Heart Valve Diseases , Mitral Valve Insufficiency , Humans , Middle Aged , Aged , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/complications , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Retrospective Studies , Treatment Outcome , Heart Valve Diseases/complications , Cardiomyopathy, Hypertrophic/diagnostic imaging , Cardiomyopathy, Hypertrophic/surgery , Cardiomyopathy, Hypertrophic/complications , Heart Failure/complications
3.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38212996

ABSTRACT

OBJECTIVES: In the last decades, 4 different scores for the prediction of mortality following surgery for type A acute aortic dissection (TAAD) were proposed. We aimed to validate these scores in a large external multicentre cohort. METHODS: We retrospectively analysed patients who underwent surgery for TAAD between 2000 and 2020. Patients were enrolled from 10 centres from 2 European countries. Outcomes were the early (30-day and/or in-hospital) and 1-year mortality. Discrimination, calibration and observed/expected (O/E) ratio were evaluated. RESULTS: A total of 1895 patients (31.7% females, mean age 63.72 ± 12.8 years) were included in the study. Thirty-day mortality and in-hospital mortality were 21.7% (n = 412) and 22.5% (n = 427) respectively. The German Registry of Acute Aortic Dissection Type A (GERAADA) score shows to have the best discrimination [area under the curve (AUC) 0.671 and 0.672] in predicting as well the early and the 1-year mortality, followed by the International Registry of Acute Aortic Dissection (IRAD) model 1 (AUC 0.658 and 0.672), the Centofanti (AUC 0.645 and 0.66) and the UK aortic score (AUC 0.549 and 0.563). According to Hosmer-Lemeshow and Brier tests, the IRAD model I and GERAADA, respectively, were well calibrated for the early mortality, while the GERAADA and Centofanti for the 1-year mortality. The O/E analysis showed a marked underestimation for patients labelled as low-risk for UK aortic score and IRAD model I for both outcomes. CONCLUSIONS: The GERAADA score showed the best performance in comparison with other scores. However, none of them achieved together a fair discrimination and a good calibration for predicting either the early or the 1-year mortality.


Subject(s)
Aortic Dissection , Azides , Deoxyglucose/analogs & derivatives , Humans , Female , Middle Aged , Aged , Male , Retrospective Studies , Aortic Dissection/surgery , Hospital Mortality , Europe , Registries , Risk Factors , Treatment Outcome
4.
Clin Res Cardiol ; 113(1): 68-74, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37294310

ABSTRACT

AIM: Transcatheter aortic valve implantation (TAVI) is a mainstay in the management of severe aortic stenosis in patients with intermediate to prohibitive surgical risk. When a single TAVI device fails and cannot be retrieved, TAVI-in-TAVI must be performed acutely, but outcomes of bailout TAVI-in-TAVI have been incompletely appraised. We aimed at analyzing patient, procedural and outcome features of patients undergoing bailout TAVI-in-TAVI in a multicenter registry. METHODS: Details of patients undergoing bailout TAVI-in-TAVI, performed acutely or within 24 h of index TAVI, in 6 international high-volume institutions, were collected. For every case provided, 2 same-week consecutive controls (prior TAVI, and subsequent TAVI) were provided. Outcomes of interest were procedural and long-term events, including death, myocardial infarction, stroke, access site complication, major bleeding, and reintervention, and their composite (i.e. major adverse events [MAE]). RESULTS: A total of 106 patients undergoing bailout TAVI-in-TAVI were included, as well as 212 controls, for a total of 318 individuals. Bailout TAVI-in-TAVI was less common in younger patients, those with higher body mass index, or treated with Portico/Navitor or Sapien devices (all p < 0.05). Bailout TAVI-in-TAVI was associated with higher in-hospital rates of death, emergency surgery, MAE, and permanent pacemaker implantation (all p < 0.05). Long-term follow-up showed that bailout TAVI-in-TAVI was associated with higher rates of death and MAE (both < 0.05). Similar findings were obtained at adjusted analyses (all p < 0.05). However, censoring early events, outlook was not significantly different when comparing the two groups (p = 0.897 for death, and p = 0.645 for MAE). CONCLUSIONS: Bail-out TAVI-in-TAVI is associated with significant early and long-term mortality and morbidity. Thus, meticulous preprocedural planning and sophisticated intraprocedural techniques are of paramount importance to avoid these emergency procedures.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Treatment Outcome , Stroke/etiology , Registries , Aortic Valve/surgery , Risk Factors
5.
J Cardiovasc Med (Hagerstown) ; 25(1): 23-29, 2024 01 01.
Article in English | MEDLINE | ID: mdl-38051649

ABSTRACT

BACKGROUND: Procedural volume has been documented as an important contributor to operative outcomes for most complex surgical procedures. Mitral valve repair (MVRep) has been associated with excellent results, and it is increasingly adopted in many cardiac surgical centers. We sought to investigate if procedural volume is associated with better clinical long-term outcomes after MVRep. METHODS: We analyzed the 10-year outcomes after MVRep by procedural volume for each cardiac surgery center in an Italian Region, Lazio, during the last 15 years, using a regional administrative dataset. RESULTS: Between 2006 and 2020, 4961 patients were treated in seven cardiac surgery centers for an isolated mitral valve surgery (2677 underwent MVRep). At multivariate analysis, mitral valve replacement (MVR) (vs. MVRep) resulted one of the independent predictors of 30-day mortality [adjusted odds ratio (OR) 3.40; 95% confidence interval (CI) 1.96-5.90; P  < 0.0001]. Notably, a clear association between hospital volume of mitral valve surgery (>40 per year) and high rate of MVRep (>50%) was found. At 10 years, the incidence of mortality and the rate of death and rehospitalization for heart failure after MVRep were significantly lower in high-volume vs. low-volume hospitals. CONCLUSION: Our data suggest that hospital volume is associated with a high rate of MVRep and long-term benefits in terms of mortality and recurrence of heart failure.


Subject(s)
Cardiac Surgical Procedures , Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Hospitals , Heart Failure/surgery , Heart Valve Prosthesis Implantation/adverse effects , Treatment Outcome
6.
J Clin Med ; 12(21)2023 Oct 24.
Article in English | MEDLINE | ID: mdl-37959183

ABSTRACT

INTRODUCTION: The most common minimally invasive approach for aortic valve replacement (AVR) is the partial upper mini-sternotomy. The aim of this study is to understand which preoperative computed tomography (CT) features are predictive of longer operations in terms of cardio-pulmonary bypass timesand cross-clamp times. METHODS: From 2011 to 2022, we retrospectively selected 246 patients which underwent isolated AVR and had a preoperative ECG-gated CT scan. On these patients, we analysed the baseline anthropometric characteristics and the following CT scan parameters: aortic annular dimensions, valve calcium score, ascending aorta length, ascending aorta inclination and aorta-sternum distance. RESULTS: We identified augmented body surface area (>1.9 m2), augmented annular diameter (>23 mm), high calcium score (>2500 Agatson score) and increased aorta-sternum distance (>30 mm) as independent predictors of elongated operation times (more than two-fold). CONCLUSIONS: Identifying the preoperative predictive factors of longer operations can help surgeons select cases suitable for minimally invasive approaches, especially in a teaching context.

8.
Biomedicines ; 11(10)2023 Oct 23.
Article in English | MEDLINE | ID: mdl-37893238

ABSTRACT

Epigenetic modifications play a fundamental role in the progression of coronary artery disease (CAD). This panoramic review aims to provide an overview of the current understanding of the epigenetic mechanisms involved in CAD pathogenesis and highlights the potential implications for personalized medicine approaches. Epigenetics is the study of heritable changes that do not influence alterations in the DNA sequence of the genome. It has been shown that epigenetic processes, including DNA/histone methylation, acetylation, and phosphorylation, play an important role. Additionally, miRNAs, lncRNAs, and circRNAs are also involved in epigenetics, regulating gene expression patterns in response to various environmental factors and lifestyle choices. In the context of CAD, epigenetic alterations contribute to the dysregulation of genes involved in inflammation, oxidative stress, lipid metabolism, and vascular function. These epigenetic changes can occur during early developmental stages and persist throughout life, predisposing individuals to an increased risk of CAD. Furthermore, in recent years, the concept of personalized medicine has gained significant attention. Personalized medicine aims to tailor medical interventions based on an individual's unique genetic, epigenetic, environmental, and lifestyle factors. In the context of CAD, understanding the interplay between genetic variants and epigenetic modifications holds promise for the development of more precise diagnostic tools, risk stratification models, and targeted therapies. This review summarizes the current knowledge of epigenetic mechanisms in CAD and discusses the fundamental principles of personalized medicine.

9.
Transpl Int ; 36: 11675, 2023.
Article in English | MEDLINE | ID: mdl-37727385

ABSTRACT

Despite the withdrawal of the HeartWare Ventricular Assist Device (HVAD), hundreds of patients are still supported with this continuous-flow pump, and the long-term management of these patients is still under debate. This study aims to analyse 5 years survival and freedom from major adverse events in patients supported by HVAD and HeartMate3 (HM3). From 2010 to 2022, the MIRAMACS Italian Registry enrolled all-comer patients receiving a LVAD support at seven Cardiac Surgery Centres. Out of 447 LVAD implantation, 214 (47.9%) received HM3 and 233 (52.1%) received HVAD. Cox-regression analysis adjusted for major confounders showed an increased risk for mortality (HR 1.5 [1.2-1.9]; p = 0.031), for both ischemic stroke (HR 2.08 [1.06-4.08]; p = 0.033) and haemorrhagic stroke (HR 2.6 [1.3-4.9]; p = 0.005), and for pump thrombosis (HR 25.7 [3.5-188.9]; p < 0.001) in HVAD patients. The propensity-score matching analysis (130 pairs of HVAD vs. HM3) confirmed a significantly lower 5 years survival (81.25% vs. 64.1%; p 0.02), freedom from haemorrhagic stroke (90.5% vs. 70.1%; p < 0.001) and from pump thrombosis (98.5% vs. 74.7%; p < 0.001) in HVAD cohort. Although similar perioperative outcome, patients implanted with HVAD developed a higher risk for mortality, haemorrhagic stroke and thrombosis during 5 years of follow-up compared to HM3 patients.


Subject(s)
Heart-Assist Devices , Hemorrhagic Stroke , Humans , Registries , Propensity Score , Magnetic Phenomena
12.
JAMA Netw Open ; 6(1): e2249321, 2023 01 03.
Article in English | MEDLINE | ID: mdl-36595294

ABSTRACT

Importance: Recent European Society of Cardiology/European Association for Cardio-Thoracic Surgery (ESC/EACTS) guidelines highlighted some concerns about the randomized clinical trials (RCTs) comparing transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) for aortic stenosis. Quantification of these biases has not been previously performed. Objective: To assess whether randomization protects RCTs comparing TAVI and SAVR from biases other than nonrandom allocation. Data Sources: A systematic review of the literature between January 1, 2007, and June 6, 2022, on MEDLINE, Embase, and Cochrane Central Register of Controlled Trials was performed. Specialist websites were also checked for unpublished data. Study Selection: The study included RCTs with random allocation to TAVI or SAVR with a maximum 5-year follow-up. Data Extraction and Synthesis: Data extraction was performed by 2 independent investigators following the PRISMA guidelines. A random-effects meta-analysis was used for quantifying pooled rates and differential rates between treatments of deviation from random assigned treatment (DAT), loss to follow-up, and receipt of additional treatments. Main Outcomes and Measures: The primary outcomes were the proportion of DAT, loss to follow-up, and patients who were provided additional treatments and myocardial revascularization, together with their ratio between treatments. The measures were the pooled overall proportion of the primary outcomes and the risk ratio (RR) in the TAVI vs SAVR groups. Results: The search identified 8 eligible trials including 8849 participants randomly assigned to undergo TAVI (n = 4458) or SAVR (n = 4391). The pooled proportion of DAT among the sample was 4.2% (95% CI, 3.0%-5.6%), favoring TAVI (pooled RR vs SAVR, 0.16; 95% CI, 0.08-0.36; P < .001). The pooled proportion of loss to follow-up was 4.8% (95% CI, 2.7%-7.3%). Meta-regression showed a significant association between the proportion of participants lost to follow-up and follow-up time (slope, 0.042; 95% CI, 0.017-0.066; P < .001). There was an imbalance of loss to follow-up favoring TAVI (RR, 0.39; 95% CI, 0.28-0.55; P < .001). The pooled proportion of patients who had additional procedures was 10.4% (95% CI, 4.4%-18.5%): 4.6% (95% CI, 1.5%-9.3%) in the TAVI group and 16.5% (95% CI, 7.5%-28.1%) in the SAVR group (RR, 0.27; 95% CI, 0.15-0.50; P < .001). The imbalance between groups also favored TAVI for additional myocardial revascularization (RR, 0.40; 95% CI, 0.24-0.68; P < .001). Conclusions and Relevance: This study suggests that, in RCTs comparing TAVI vs SAVR, there are substantial proportions of DAT, loss to follow-up, and additional procedures together with systematic selective imbalance in the same direction characterized by significantly lower proportions of patients undergoing TAVI that might affect internal validity.


Subject(s)
Aortic Valve , Heart Valve Prosthesis Implantation , Humans , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Risk Factors , Randomized Controlled Trials as Topic , Bias
13.
Minerva Cardiol Angiol ; 71(3): 324-332, 2023 Jun.
Article in English | MEDLINE | ID: mdl-35332751

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is emerging as an appealing management strategy for patients with severe aortic stenosis at intermediate, high or exceedingly high risk, but its risk-benefit profile in younger patients is less certain. We aimed to explore the outlook of patients aged 70 years or less and undergoing TAVI at 2 high-volume Italian institutions. METHODS: We retrospectively collected baseline, imaging, procedural and outcome features of patients with age ≤70 years in whom TAVI was attempted at participating centers between 2012 and 2021. Non-parametric tests and bootstrap resampling were used for inferential purposes. RESULTS: A total of 39 patients were included, out of >3000 screened with heart team involvement and >1500 receiving TAVI. Most common or relevant indications for TAVI reduced life expectancy (e.g. cardiogenic shock or severe left ventricular systolic dysfunction), chronic obstructive pulmonary disease, morbid obesity, active or recent extra-cardiac cancer, porcelain aorta, neurologic disability, cirrhosis, or prior surgical aortic valve replacement, as well as extreme cachexia, and Hutchinson-Gilford progeria. At least two contemporary high-risk features were present in most cases. Transapical access was used in 5 (12.8%) cases, and a sheathless approach in 15 (38.5%). A variety of devices were used, including both balloon- and self-expandable devices. Clinical outcomes were satisfactory, despite the high-risk profile, at both short- and mid-term, with no in-hospital death, and 5.1% (95% confidence interval 0-12.8%) mortality at a median follow-up of 15 months (minimum 1; maximum 85). Notably, no case of significant valve deterioration requiring reintervention occurred. CONCLUSIONS: In carefully selected patients with 70 years or less of age and prohibitive risk for surgery or reduced life expectancy, TAVI represents a safe option with a favorable mid-term survival and low rate of adverse events.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Retrospective Studies , Aortic Valve Stenosis/surgery , Treatment Outcome , Aortic Valve/surgery
14.
Heart Lung Circ ; 32(3): 387-394, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36566143

ABSTRACT

AIM: The aim of this study was to assess the impact of surgeon experience and centre volume on early operative outcomes in patients undergoing off-pump coronary artery bypass (OPCAB) surgery. METHOD: Of 7,352 patients in the European Multicenter Study on Coronary Artery Bypass Grafting (E-CABG) registry, 1,549 underwent OPCAB and were included in the present analysis. Using adjusted regression analysis, we compared major early adverse events after procedures performed by experienced OPCAB surgeons (i.e., ≥20 cases per year; n=1,201) to those performed by non-OPCAB surgeons (n=348). Furthermore, the same end points were compared between procedures performed by OPCAB surgeons in high OPCAB volume centres (off-pump technique used in >50% of cases; n=894) and low OPCAB volume centres (n=307). RESULTS: In the experienced OPCAB surgeon group, we observed shorter procedure times (ß -43.858, 95% confidence interval [CI] -53.322 to -34.393; p<0.001), a lower rate of conversion to cardiopulmonary bypass (odds ratio [OR] 0.284, 95% CI 0.147-0.551; p<0.001), a lower rate of prolonged inotrope or vasoconstrictor use (OR 0.492, 95% CI 0.371-0.653; p<0.001), a lower rate of early postprocedural percutaneous coronary interventions (OR 0.335, 95% CI 0.169-0.663; p=0.002), and lower 30-day mortality (OR 0.423, 95% CI 0.194-0.924; p=0.031). In high OPCAB volume centres, we found a lower rate of prolonged inotrope use (OR 0.584, 95% CI 0.419-0.814; p=0.002), a lower rate of postprocedural acute kidney injury (OR 0.382, 95% CI 0.198-0.738; p=0.004), shorter duration of intensive care unit (ß -1.752, 95% CI -2.240 to -1.264; p<0.001) and hospital (ß -1.967; 95% CI -2.717 to -1.216; p<0.001) stays, and lower 30-day mortality (OR 0.316, 95% CI 0.114-0.881; p=0.028). CONCLUSIONS: Surgeon experience and centre volume may play an important role on the early outcomes after OPCAB surgery.


Subject(s)
Coronary Artery Bypass, Off-Pump , Surgeons , Humans , Coronary Artery Bypass, Off-Pump/adverse effects , Coronary Artery Bypass, Off-Pump/methods , Coronary Artery Bypass/adverse effects , Coronary Artery Bypass/methods , Time Factors , Registries , Treatment Outcome
15.
Int J Cardiol ; 371: 116-120, 2023 Jan 15.
Article in English | MEDLINE | ID: mdl-36108764

ABSTRACT

OBJECTIVES: The role of the underlying etiology in isolated tricuspid valve surgery has not been investigated extensively in current literature. Aim of this study was to analyse outcomes of patients undergoing surgery due to endocarditis compared to other pathologies. METHODS: The SURTRI study is a multicenter study enrolling adult patients who underwent isolated tricuspid valve surgery (n = 406, 55 ± 16 y.o.; 56% female) at 13 international sites. Propensity weighted analysis was performed to compare groups (IE group n = 107 vs Not-IE group n = 299). RESULTS: No difference was found regarding the 30-day mortality (Group IE: 2.8% vs Group Not-IE = 6.8%; OR = 0.45) and major adverse events. Weighted cumulative incidence of cardiac death was significantly higher for patients with endocarditis (p = 0.01). The composite endpoint of cardiac death and reoperation at 6 years was reduced in the Group IE (63.2 ± 6.8% vs 78.9 ± 3.1%; p = 0.022). Repair strategy resulted in an increased late survival even in IE cases. CONCLUSIONS: Data from SURTRI study report acceptable 30-day results but significantly reduced late survival in the setting of endocarditis of the tricuspid valve. Multi-disciplinary approach, repair strategy and earlier treatment may improve outcomes.


Subject(s)
Endocarditis , Heart Valve Prosthesis Implantation , Adult , Humans , Female , Male , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Prognosis , Treatment Outcome , Endocarditis/diagnosis , Endocarditis/surgery , Endocarditis/etiology , Reoperation , Death , Heart Valve Prosthesis Implantation/methods , Retrospective Studies
16.
J Clin Med ; 13(1)2023 Dec 27.
Article in English | MEDLINE | ID: mdl-38202159

ABSTRACT

BACKGROUND: Infective endocarditis (IE) is a serious disease, and in many cases, surgery is necessary. Whether the type of prosthesis implanted for aortic valve replacement (AVR) for IE impacts patient survival is a matter of debate. The aim of the present study is to quantify differences in long-term survival and recurrence of endocarditis AVR for IE according to prosthesis type among patients aged 40 to 65 years. METHODS: This was an analysis of the INFECT-REGISTRY. Trends in proportion to the use of mechanical prostheses versus biological ones over time were tested by applying the sieve bootstrapped t-test. Confounders were adjusted using the optimal full-matching propensity score. The difference in overall survival was compared using the Cox model, whereas the differences in recurrence of endocarditis were evaluated using the Gray test. RESULTS: Overall, 4365 patients were diagnosed and operated on for IE from 2000 to 2021. Of these, 549, aged between 40 and 65 years, underwent AVR. A total of 268 (48.8%) received mechanical prostheses, and 281 (51.2%) received biological ones. A significant trend in the reduction of implantation of mechanical vs. biological prostheses was observed during the study period (p < 0.0001). Long-term survival was significantly higher among patients receiving a mechanical prosthesis than those receiving a biological prosthesis (hazard ratio [HR] 0.546, 95% CI: 0.322-0.926, p = 0.025). Mechanical prostheses were associated with significantly less recurrent endocarditis after AVR than biological prostheses (HR 0.268, 95%CI: 0.077-0.933, p = 0.039). CONCLUSIONS: The present analysis of the INFECT-REGISTRY shows increased survival and reduced recurrence of endocarditis after a mechanical aortic valve prosthesis implant for IE in middle-aged patients.

17.
Eur Heart J Case Rep ; 6(11): ytac413, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36466130

ABSTRACT

Background: Retained cardiac missiles have been considered bullets, shrapnel, or pellets included in the heart or the pericardial sac. In asymptomatic patients with retained cardiac missiles, the role of surgery is still debated. Case summary: We describe the case of successful surgical treatment of a retained missile localized within the left ventricle in close proximity of the posterior mitral leaflet. The operation was performed through a transatrial approach, detaching the posterior mitral leaflet. The post-operative course was uneventful. The patient was discharged on the seventh post-operative day. At 30-day follow-up visit, the patient was in good conditions, with normal mitral valve function. Discussion: The management of retained cardiac missiles should be individualized. If a decision is made to operate, multiple imaging techniques including echocardiography and computed tomography scan are mandatory to precisely locate the bullet.

19.
J Card Surg ; 37(12): 4269-4277, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36285550

ABSTRACT

BACKGROUND: Degenerative mitral valve (MV) regurgitation (DMR) shows significative mitral annulus (MA) alterations; mitral valve repair (MVR) seeks to restore annular geometry and function, and the current use of flexible band seams to respect most annular mobility reducing parietal stress. Parameters of MV geometry obtained by 3D transesophageal echocardiography (3D-TTE) analysis are crucial for surgical planning and postoperative success. The aim of this study was to assess, by means of a dedicated software, the variations of MA geometry and function in patients affected by DMR compared to controls and after MVR with flexible band. METHODS: We enrolled 32 patients (cases) with severe DMR who underwent MVR using flexible band; we compare this group with 20 controls. The TEE with 3D MV images acquisition was performed in both groups and then analyzed in postprocessing by using a dedicated software. RESULTS: There were no anthropometrics differences between cases and controls, both presented normal left ventricular ejection fraction. DMR group showed a significant increase of annulus dimensional parameters (p = .001) and alteration of nonplanarity comparing to controls (p < .05). The annuloplasty with flexible band induces a considerable reduction of MV dimensions comparing to preoperative data and restores physiological mobility and nonplanarity. There were no statistical differences between postoperative DMR and controls data, except for nonplanarity parameters (p ~.05), maybe influenced by hemodynamic settings. CONCLUSIONS: MVR with annuloplasty using flexible band appears able to reinstate a more physiological anatomic conformation of the MA, without compromising its dynamic properties.


Subject(s)
Echocardiography, Three-Dimensional , Mitral Valve Annuloplasty , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Stroke Volume , Ventricular Function, Left , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Mitral Valve Annuloplasty/methods
20.
Tex Heart Inst J ; 49(5)2022 09 01.
Article in English | MEDLINE | ID: mdl-36149934

ABSTRACT

In the complex spectrum of coronary anomalies, the origin of the left coronary artery from the right sinus of Valsalva with intramural course could represent a catastrophic life-threatening condition leading to extensive myocardial infarction and sudden cardiac death, especially in young athletes. We report the case of a young female athlete with anomalous left coronary artery from the opposite sinus who survived a major non-ST-elevation myocardial infarction during the eighth kilometer of a running race. It was successfully treated by creating a neo-ostium of the left coronary artery in the left sinus at the point at which the artery left the aortic wall.


Subject(s)
Anomalous Left Coronary Artery , Coronary Vessel Anomalies , Myocardial Infarction , Sinus of Valsalva , Athletes , Coronary Angiography , Coronary Vessel Anomalies/complications , Coronary Vessel Anomalies/diagnosis , Coronary Vessel Anomalies/surgery , Female , Humans , Myocardial Infarction/complications , Myocardial Infarction/diagnosis , Sinus of Valsalva/abnormalities , Sinus of Valsalva/diagnostic imaging , Sinus of Valsalva/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...