1.
Sensors (Basel) ; 24(11)2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38894467

ABSTRACT

Hydrogels are of great importance for functionalizing sensors and microfluidics, and poly(ethylene glycol) dimethacrylate (PEG-DMA) is often used as a viscosifier for printable hydrogel precursor inks. In this study, 1-10 kDa PEG-DMA based hydrogels were characterized by gravimetric and electrochemical methods to investigate the diffusivity of small molecules and proteins. Swelling ratios (SRs) of 14.43-9.24, as well as mesh sizes ξ of 3.58-6.91 nm were calculated, and it was found that the SR correlates with the molar concentration of PEG-DMA in the ink (MCI) (SR = 0.1127 × MCI + 8.3256, R2 = 0.9692) and ξ correlates with the molecular weight (Mw) (ξ = 0.3382 × Mw + 3.638, R2 = 0.9451). To investigate the sensing properties, methylene blue (MB) and MB-conjugated proteins were measured on electrochemical sensors with and without hydrogel coating. It was found that on sensors with 10 kDa PEG-DMA hydrogel modification, the DPV peak currents were reduced to 92 % for MB, 73 % for MB-BSA, and 23 % for MB-IgG. To investigate the diffusion properties of MB(-conjugates) in hydrogels with 1-10 kDa PEG-DMA, diffusivity was calculated from the current equation. It was found that diffusivity increases with increasing ξ. Finally, the release of MB-BSA was detected after drying the MB-BSA-containing hydrogel, which is a promising result for the development of hydrogel-based reagent reservoirs for biosensing.

2.
Front Bioeng Biotechnol ; 11: 1166857, 2023.
Article in English | MEDLINE | ID: mdl-37251564

ABSTRACT

The ELSAH (electronic smart patch system for wireless monitoring of molecular biomarkers for healthcare and wellbeing) project has received funding from EU's Horizon 2020 research and innovation program (grant agreement no. 825549). Its aim is to develop a wearable smart patch-based microneedle sensor system that can simultaneously measure several biomarkers in users' dermal interstitial fluid. This system could have several use cases based on continuous glucose and lactate monitoring: early detection of (pre-) diabetes mellitus, increasing physical performance through optimal carbohydrate intake, achieving a healthier lifestyle through behavioral changes based on the interpretation of glucose data, performance diagnostics (lactate threshold test), control of optimal training intensities corresponding with certain lactate levels, or warning of diseases/health threats, such as the metabolic syndrome or sepsis associated with increased lactate levels. The ELSAH patch system has a high potential of increasing health and wellbeing in users.

3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 1275-1278, 2022 07.
Article in English | MEDLINE | ID: mdl-36086365

ABSTRACT

Microneedles (MN) are short, sharp structures that have the ability to painlessly pierce the stratum corneum, the outermost layer of the skin, and interface with the dermal interstitial fluid that lies beneath. Because the interstitial fluid is rich in biomarkers, microneedle-based biosensors have the potential to be used in a wide range of diagnostic applications. To act as an electrochemical sensor, the tip or the body of the MN must be functionalized, while the substrate areas are generally passivated to block any unwanted background interference that may occur outside of the skin. This work presents four different passivation techniques, based on the application of SiO2, polymethyl methacrylate (PMMA), an adhesive film, and varnish to the substrate areas. Optical, SEM and electrochemical measurements were performed to quantitatively assess the performance of each film. The data shows that whilst manual application of varnish provided the highest level of electrical isolation, the spin-coating of a 5 µm thick layer of PMMA is likely to provide the best combination of performance and manufacturability. Clinical Relevance- Substrate passivation techniques will improve the performance of microneedle-based non-invasive continuous monitoring systems.


Subject(s)
Biosensing Techniques , Polymethyl Methacrylate , Needles , Silicon Dioxide , Skin
4.
Nanotechnology ; 24(31): 315501, 2013 Aug 09.
Article in English | MEDLINE | ID: mdl-23851634

ABSTRACT

In this work, we present calculated numerical values for the kinetic parameters governing adsorption/desorption processes of carbon monoxide at tin dioxide single-nanowire gas sensors. The response of such sensors to pulses of 50 ppm carbon monoxide in nitrogen is investigated at different temperatures to extract the desired information. A rate-equation approach is used to model the reaction kinetics, which results in the problem of determining coefficients in a coupled system of nonlinear ordinary differential equations. The numerical values are computed by inverse-modeling techniques and are then used to simulate the sensor response. With our model, the dynamic response of the sensor due to the gas-surface interaction can be studied in order to find the optimal setup for detection, which is an important step towards selectivity of these devices. We additionally investigate the noise in the current through the nanowire and its changes due to the presence of carbon monoxide in the sensor environment. Here, we propose the use of a wavelet transform to decompose the signal and analyze the noise in the experimental data. This method indicates that some fluctuations are specific for the gas species investigated here.