Pediatr Int ; 56(2): 227-9, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24274748

ABSTRACT

BACKGROUND: The breathing intolerance index (BITI) is used to justify ventilator use in adult patients with pulmonary or chest wall disease. BITI in ventilated patients is mostly ≥0.15. The mean BITI of healthy adults in the upright sitting position and the supine position is 0.050 ± 0.009 and 0.057 ± 0.016, respectively. The aim of this study was to establish a normal BITI in infants. METHODS: Thirty healthy infants were examined in the supine position. BITI was defined as BITI = (Ti/Ttot) × (TV/VC), where Ti is inspiratory time, Ttot is total breath cycle duration, TV is tidal volume, and VC is vital capacity. TV and Ti/Ttot were obtained from tidal breathing at rest and VC was obtained spirometrically. BITI was calculated using customized software. RESULTS: The mean ± SD BITI of 30 healthy infants in the supine position was 0.120 ± 0.013. The BITI of infants was significantly higher than that of adults. CONCLUSIONS: BITI was measured in healthy infants. Further evaluation is needed to determine the significance and usefulness of BITI.


Subject(s)
Diaphragm/physiology , Respiration , Female , Humans , Infant, Newborn , Male , Reference Values , Respiratory Function Tests